DIGITAL ACCESS CONTROL KEYPAD
DK-9830
INSTALLATION AND OPERATION INSTRUCTIONS
1.
FEATURES AND FUNCTIONS
•
Simple Programming, Easy Operation
•
Tamper Beep ON/OFF Selectable
•
1 Relay Output
•
Tamper Switch can be Connected to Security Alarm System
•
250 Users
•
Egress Input for Door-open Remote Triggering
•
Multi User Code or Single User Code Operation
•
Doorbell Button
•
Operates Fail-safe or Fail-secure Electric Locks
•
Features are Keypad Programmable
•
Auto Code Entry or Manual Code Entry
•
Non-volatile Memory in Power Failure
•
Keypad Blocking for 30 Seconds after 10 False Entries
2.
SPECIFICATIONS
Operating Voltage
:
12V DC
Current Drain
:
Quiescent State = 24mA, Active State=68mA (1 Relay actuated, all LED lighted)
Relay Output Contacts
:
N.O. and N.C. Dry Contacts, Max Rating of Contact Current 3A / 24V DC
Capacity of Recording
:
250 Codes or 1 Common Code
Dimensions
:
117 (H) mm x 117 (W) mm x 21 (D) mm
Weight
:
140g
3.
AUDIBLE & VISIBLE INDICATIONS
Definition of
Status
Output
Audible
Key Act
Audible and Visible
Indicator
Indicator
Indicator
Lamp
Indications
Amber LED
Green LED
Buzzer
Clear LED
Standby mode
1 Flash in 2 Sec interval
Successful key entry
1 Flash then light for 10 Sec
(Press # to return to standby mode)
1 Beeps
Light for 10 Sec
Successful code entry
2 Flashes
Light
2 Beeps
Successful operation
2 Flashes
2 Beeps
Unsuccessful code entry
5 Flashes
5 Beeps
Unsuccessful operation
5 Flashes
5 Beeps
In blocking status
(no response to code entry)
1 Flash in 10 Sec interval
1 Short beep in 10 Sec interval
1 Long beep finish blocking
In programming mode
Light
Light
During programming
Light
Continuous
Flash
Programming confirmation
(PRESS KEY #)
Light
Light
2 Beeps
Alarm status
Continuous flash
Continuous beeps
Notice to user :
(1) Successful key entry, it will keep 10 seconds, if no further key entry in 10 seconds, It will return to normal operation
status (Standby mode).
(2) In case of wrong entry, cancel the wrong entry by pressing key #, or waiting for 10 seconds then re-enter.
4.
PROGRAMMING
Before use of the new access control keypad, programming every item to confirm the functions and settings meet the requirement of the users
Programming Code = Management Code
= Master Code
Default programming code is 1234
NOTE :
(1)
Successful programming operation
-
The amber LED will show 2 flash and the buzzer will sound 2 beeps.
Unsuccessful programming operation
-
The amber LED will show 5 flash and the buzzer will sound 5 beeps.
(2)
The User ID Number /User Code, are not allowed to record repeatedly. Repeat record will not be entered and will give
warning signal : amber LED 5 flash, buzzer sound 5 beeps to signify rejection. It is required to delete the old data then
re-enter.
1