– 28 –
Dryer Components
WARNING:
Sharp edges may be exposed when
servicing the dryer. Use caution to avoid injury.
Wear Kevlar gloves or equivalent protection.
Top Cover
Removal of the top cover provides access to the
control panel and front panel. Two Phillips-head
screws are located at the rear of the top cover. After
removal of the screws, the cover can then be slid
rearward 1 inch, and then lifted to disengage it from
the cabinet.
Top View
Control Panel
The control panel is held in place with 4 Phillips-
head screws and 4 tabs. Two tabs engage the front
brace and 2 tabs engage the cabinet front.
To remove the control panel:
1. Remove the top panel. (See
Top Cover
.)
2. Pull to remove the condensation tank.
3. Remove the 2 Phillips-head screws that attach
the top of the control panel to the top brace.
3. Remove the 2 Phillips-head screws that attach
the front of the control panel to the cabinet
front.
4. Pull the top of the panel up and out from the top
brace, and then lift the panel off of the cabinet
front.
Top Brace
Cabinet Front
5. Disconnect the control panel wires and
harnesses.