Fix the mounting position and secure
the suspension by tightening the two
screws on both mounting brackets.
9
Clip luminaire to the previously
installed mountingbrackets.
8
10
Replace power supply cover(s) by
sliding over the captive screws and
secure by tightening them.
Note:
When installation iscomplete,
all lead wires and connectors shall
be totallyenclosed.
7
Optional dimmer:
Install UL listed
electrical fitting and insert dimming
control wires through. Connect
dimming control wires (grey and violet
for 0-10V or violet and violet/white strip
for DALI) to the similarly colored fixture
wire using separate UL listed wire nuts.
Dimming line
(optional)
Dimming
wires
DALI
Fixture
Line
Neutral
Black
White
Ground
Green
DALI
Violet/White
DALI
Violet
Black
White
Green
Violet
Grey
Wiring Diagrams
0-10V
Fixture
Line
Neutral
Ground
(0-10V)+
(0-10V)–
For 347V ftxture:
Loosen PSU cover
screws and remove two covers.
4
4
Carefully remove appropriate knockout
for AC line input wires (inner knockout
for ½” conduit, outer knockout for
¾” conduit). Install listed electrical
fittings in the knockout holes for wire
protection and pass supply conduit
through electrical fittings.
5
Connect the green (ground), black
(line) and white (neutral) wires of
the ACline to the similarly colored
wires of the power supply unitusing
separate UL listed wire nuts.
6
ACline
ACline
PSU
wires
Prepare luminaire for installation
by loosening the PSU cover screws
and removing the cover.
3