Section 7 - PROGRAMMABLE OPTIONS
9
Data Manager Options
To configure the System Monitor to work with the different data interfaces remove all option
jumpers from headers W3A-W3D, W4A-W4H, W5A-W5H, W7 and W8A-W8E and install jumpers
as specified in Table 1.
Table 1. Data Manager Options
OPTION
INSTALL JUMPERS
Dynamic Data Manager
®
or
Transient Data Manager
®
or
No
Data
Interface
Internal
Serial Data Interface/
Dynamic Data Interface
External
Serial Data Interface/
Dynamic Data Interface or
Transient
Data
Interface
W3A,W3B,W5A,W5B,W5C,W5D,W5E,*
W5F,W5G,W5H,W8D & W8E
W3C,W3D,W4A,W4B,W4C,W4D,W4E,**
W4F,W4G,W4H,W7,W8D & W8E
W3C,W3D,W5A,W5B,W5C,W5D,W5F,
W5G,W5H,W8A,W8B & W8C
* As shipped from factory for a 3300/03 - 01 System Monitor.
** As shipped from factory for a 3300/03 - 02 or 3300/03 - 03 System Monitor.
-VT Options
To set the -VT option according to the option set on the Power Supply, remove jumpers from
headers W1 and W2 and install jumpers as specified in Table 2.
Table 2. -VT Options
OPTION
INSTALL
JUMPER
REMOVE
JUMPER
-VT = -18 Volts
-VT = -24 Volts
W2
W1
W1
W2