background image

Consumer Support

Troubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will keep

it from draining properly. To adjust for this, attach 

a piece of wood to the stool.

WOOD PIECES—

WIDTH:

2

LENGTH: 

Long enough to fit inside the window

frame.

THICKNESS: 

To determine the thickness, place a

piece of wood on the stool to make it 1/2

higher

than the top of the storm window frame.
Attach securely with nails or screws provided by 

the installer.

2

Read completely, then follow step-by-step.

1/2

higher

than frame

Storm window
frame

Wood

Stool

Remove the Front Grille, if attached

To remove the grille: 

Remove shipping tape if present.

On models with a slide out air filter, remove 

it (see the Care and Cleaning section) and 

the screw behind it (if present) that holds 

the grille in place. 

On models with a raise up inlet grille, lift it

(see the Care and Cleaning section) and

remove the screw behind it (if present) that

holds the grille in place.

A

Pull the bottom grille corners out to release

the lower tabs on each side.

B

NOTE: 

Do not pull the bottom edge toward you more

than 3 inches or you may damage the tabs of the grille.

Lift the grille

up and off the

top tabs.

C

3

11

Window Requirements 

These instructions are for a standard double-
hung window. You will need to modify them for
other types of windows.

The air conditioner can be installed without 
the accordion panels if needed to fit in a narrow
window. See the window opening dimensions 
at right.

All supporting parts must be secured to firm
wood, masonry or metal.

The electrical outlet must be within reach of the
power cord. 

1

17

3

8

min.

30

to 41

(With accordion panels)

26

″ 

min.

(Without accordion panels)

Summary of Contents for ASM12

Page 1: ...g Instructions Controls Control Knobs 6 7 Controls Touch Pads 4 5 Care and Cleaning Air Filter 8 Grille and Case 8 Outdoor Coils 8 Installation Instructions Through the Wall Installation Optional 15 W...

Page 2: ...in the vicinity of this or any other appliance SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be pro...

Page 3: ...made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall ou...

Page 4: ...tions of room temperature and humidity Normally used when the room is unoccupied Note The fan will continue to run for a short time after the compressor cycles off OFF The fan runs all the time while...

Page 5: ...d off to keep the room at the set level of comfort Set the thermostat at a lower number and the indoor air will become cooler Set the thermostat at a higher number and the indoor air will become warme...

Page 6: ...ol at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint T...

Page 7: ...it to the left Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results in wider variations of room temperature and humidi...

Page 8: ...rofessionally steam cleaned a service available through your GE service outlet Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water...

Page 9: ...power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115...

Page 10: ...Preparing to Install the Air Conditioner before beginning Parts Included Window Installation Instructions Type A 22 or 23 Security bracket Top mounting rail Right accordion panel Foam top window gask...

Page 11: ...t air filter remove it see the Care and Cleaning section and the screw behind it if present that holds the grille in place On models with a raise up inlet grille lift it see the Care and Cleaning sect...

Page 12: ...bottom mounting rails Attach the accordion panels to the side of the case using 8 type A screws B A Remove the Air Conditioner From the Case Remove the 2 screws on each side of the case Keep these fo...

Page 13: ...ide wall Attach a V support to each side of the bottom of the case using type A screws 4 on each side Adjust the type C leveling bolts against the outside wall so that the case has a slight tilt to th...

Page 14: ...totheslotsonthefrontofthe case Pushthegrilleinuntilitsnapsintoplace Securethefrontgrilletothecasebyreplacing thescrewremovedinStep3 Ifascrewwasnot removedinStep3 securethegrillewithatypeA screw Theins...

Page 15: ...certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and secure with 12 1 long 10 wood screws NOTE Drill p...

Page 16: ...s with touch pads In COOL mode press the not be set correctly DECREASE pad On models with control knobs turn the temperature knob to a higher number The air filter is dirty Clean the filter at least e...

Page 17: ...tection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more...

Page 18: ...ct detach and return the form below to ensure that your product is registered or register online at www GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Produ...

Page 19: ...to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of hou...

Page 20: ...ts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after y...

Reviews: