background image

15

Through-the-Wall Installation Instructions—Optional

The case may be installed through-the-wall
in both existing and new construction.

Read completely, then follow step-by-step.

NOTE: Obtain all materials locally for
mounting the air conditioner through-
the-wall.

IMPORTANT

Through-the-wall installation is not
appropriate if any of the side or top louvers
in the case will be obstructed by the wall.

All side and top louvers in the case must
project on the outdoor side of the wall.

The room side of the case must project 
into the room far enough to maximize the
balance of the unit.

The case must be installed level from side-
to-side and with a slight tilt from front to
rear. Use a level; no more than a 1/2 bubble
will be the correct case slant to the outside.

Lintel angle is required to support bricks or
blocks above opening.

Flashing is required and should extend the
length of the opening to ensure no inside
cavity leakage occurs.

Remove the air conditioner from the case.
For specific instruction, refer to the Window
Installation Instructions.

Make certain that a wall receptacle is
available close to the hole location or make
arrangements to install a receptacle.

Place the case in the wall opening and 
place wood support strips between the case
bottom and the flashing on both sides of the
bottom rail. They should be the same height
as the bottom rail and the same length as
the wall opening.

1

A

B

FINISH THE WALL OPENING

Caulk all four sides on the outdoor side of
the case to prevent moisture from getting
through to the interior wall. Use of flashing
(drip rail) will further prevent water from
dripping inside the wall and down the
outside of the building.

Place the air conditioner into the case. 
For specific instruction, refer to the Window
Installation Instructions.

2

IMPORTANT 

(cont.)

Secure with 14 wood screws anchored at
least an inch into the wall support structure.

NOTE:

Drill pilot holes, if necessary, for

proper installation. If the frame is oversized,
use shims to prevent case distortion.

1

D

A

B

Lintel angle

Plaster line

Trim molding
(if desired)

INSIDE

Bottom rail

Wood filler and
caulking (above
and below the
flashing)

Air louvers
(top and
sides must
project on the
outdoor side
of the wall)

OUTSIDE

Flashing 
(Drip rail)

Case 
bottom

Bottom
rail

Flashing 
(Drip rail)

Wood support strips

Caulking

C

Summary of Contents for ASM08*

Page 1: ...Support Consumer Support 20 Product Registration 17 18 Warranty 19 49 7581 11 07 JR ASD06 ASM08 ASM10 ASM12 ASQ10 ASQ12 ASQ14 ASV10 ASV12 ASV14 Air Conditioners Owner s Manual and Installation Instru...

Page 2: ...moved prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances c...

Page 3: ...if you must use an extension cord it is absolutely necessary that it be a UL listed 14 gauge 3 wire grounding type appliance extension cord having a grounding type plug and outlet and that the electr...

Page 4: ...Energy Saver Controls the fan On The fan and compressor cycle on and off This results in wider variations of room temperature and humidity Normally used when the room is unoccupied Note The fan will...

Page 5: ...er and the indoor air will become warmer NOTE If the air conditioner is off and is then turned on while set to Cool it will take approximately 3 minutes for the compressor to start and cooling to begi...

Page 6: ...ard the larger blue area For Quieter Nighttime Cooling Select a Cool mode with the Mode Temp knob set toward the smaller blue area NOTE If you move the Mode Temp control knob from a Cool setting to th...

Page 7: ...OSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside Air Direction Side to Side On some models the side to side air direction is ad...

Page 8: ...itioner off and remove the plug from the wall outlet before cleaning To clean use water and a mild detergent Do not use bleach or abrasives Care and cleaning of the air conditioner 8 Consumer Support...

Page 9: ...ve these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical skills Completion time Approx...

Page 10: ...structions Sill support 2 Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 8 3 4 screws Type C bolt 2 Security bracket 1 Top mounting rail se...

Page 11: ...roperly To adjust for this attach a piece of wood to the sill WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the si...

Page 12: ...on panels to the side of the case using 6 type A screws Window Installation Instructions 12 REMOVE THE AIR CONDITIONER FROM THE CASE Remove the 2 or 4 screws depending on model on each side of the cas...

Page 13: ...accessory kit RAK87 to properly install this air conditioner Call 800 626 2002 or visit ge com 6 A B INSTALL THE SECURITY BRACKET AND THE FOAM TOP WINDOW GASKET Attach the security bracket with a type...

Page 14: ...nds on both sides and push them in Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case Push the grille in until it snaps into place Secure t...

Page 15: ...ertain that a wall receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and place wood support strips between the case bot...

Page 16: ...On models with control knobs turn the temperature knob to a higher number The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The room may have been...

Page 17: ...tection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more...

Page 18: ...t here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the regist...

Page 19: ...ed after delivery Product not accessible to provide required service What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home us...

Page 20: ...ble while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expir...

Page 21: ...ales de operaci n 18 Apoyo al consumidor Apoyo al consumidor 20 Garant a 19 49 7581 11 07 JR ASD06 ASM08 ASM10 ASM12 ASQ10 ASQ12 ASQ14 ASV10 ASV12 ASV14 Acondicionadores de Aire Manual del propietario...

Page 22: ...planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indiquen qu hacer PRECAUCIONES DE SEGURIDAD Bajo ningu...

Page 23: ...sar un cable el ctrico de extensi n es absolutamente necesario que el mismo est listado bajo UL sea calibre 14 del tipo de 3 tomas con conexi n a tierra para electrodom sticos y el ndice el ctrico deb...

Page 24: ...ocupada Nota El ventilador continuar funcionando por un corto tiempo despu s de que el compresor haya entrado en el ciclo de apagado Off Apagado El ventilador funciona todo el tiempo mientras que el...

Page 25: ...iclo entre apagado y encendido para mantener la habitaci n a la temperatura deseada Ajuste el termostato a un n mero menor y el aire interno se enfriar m s Si lo ajusta a un n mero mayor la temperatur...

Page 26: ...enfriamiento normal Seleccione un modo Cool Enfriado con el bot n Mode Temp en la posici n del centro Para enfriamiento m ximo Seleccione un modo Cool Enfriado con el bot n Mode Temp apuntando hacia...

Page 27: ...ocalizado al interior de las persianas en la esquina derecha inferior Cuando est ajustado en CLOSE CERRADO solamente el aire en el interior de la habitaci n circular y se acondicionar Cuando est ajust...

Page 28: ...bater as nuevas cercior ndose de que los polos positivos y negativos est n orientados correctamente Coloque la cubierta otra vez desliz ndola en su lugar NOTAS Use 2 bater as AAA de 1 5 voltios No use...

Page 29: ...conexi n a tierra REQUISITOS ELECTRICOS Algunos modelos requieren 230 208 voltios de corriente alterna protegidos por un fusible de dilataci n de tiempo o un cortacircuitos Estos modelos deber an ins...

Page 30: ...ior de espuma de la ventana Sello del marco de la ventana Panel de acorde n izquierdo Tornillos 3 4 tipo B 8 Perno tipo C 2 Soporte de seguridad 1 Cinta de sellado del riel de montaje superior Empaque...

Page 31: ...n algunas ventanas Marco vinilo Madera Instrucciones para la instalaci n en una ventana REQUISITOS PARA LA VENTANA Estas instrucciones son para una ventana est ndar de dos pliegues Usted necesitar mod...

Page 32: ...a parrilla presione en los lados de la caja y tire para liberar NOTA No tire los extremos de la parte inferior hacia usted m s de 3 o podr a da ar las orejillas de la parrilla Levante la parrilla y li...

Page 33: ...VENTANA Corte el sello del marco de la ventana de acuerdo con el ancho de la ventana y pegue el lado adhesivo al fondo del marco Enrosque dos pernos tipo C en los soportes de apoyo Deslice la caja ha...

Page 34: ...A B C D Empaque inferior de la caja Frente del acondicionador de aire Gu e la palanca cuidadosamente a trav s de la parrilla mientras la empuja INSTALE EL SOPORTE DE SEGURIDAD Y LA PARTE SUPERIOR DE...

Page 35: ...buja Es necesaria una escuadra de lintel para dar soporte a los ladrillos o bloques que se encuentran por encima de la abertura Se necesitan tapajuntas que deben extenderse a lo largo de la abertura p...

Page 36: ...ci n Coloque el acondicionador de aire hacia el interior de la caja Para instrucciones espec ficas refi rase a las Instrucciones para la instalaci n en una ventana 2 ngulo del lintel L nea del yeso Mo...

Page 37: ...a ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamiento Ver Acondicionador de aire se est congelando m s adelante se congelaron El acondicionador de aire El hielo bl...

Page 38: ...as lluviosos o cuando la humedad es alta Esta caracter stica de dise o ayuda a remover la humedad y mejora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre...

Page 39: ...acilitar el servicio requerido Lo que no est cubierto Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unid...

Page 40: ...uier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Piezas y accesorios ge com Aquellos individuos con la califica...

Reviews: