20
31-5000560 Rev. 5
Installation Instructions
Step 3 - Installation of the Outdoor Unit (Cont.)
Model:
ASH436NCDDA
ASH542JCDDA
Outdoor unit
Power Wiring
3
2
1
)
(N
)
(L
)
(C
2
1
)
(N
)
( L
Indoor unit A
Control Wiring
4 Wire - 14 AWG
Stranded
To Service Disconnect
1
2
3
=White
=Black
=Red
=Green
A
B
C
D
Sugested Colors
230 Volt Supply. 1 to L1, 2 to L2.
Indoor unit B
Indoor unit C
Indoor unit D
3
2
1
)
(N
)
(L
)
(C
3
2
1
)
(N
)
(L
)
(C
3
2
1
)
(N
)
(L
)
(C
Strain Relief
Brackets
E
3
2
1
)
(N
)
(L
)
(C
Model Number
Factory
Charge
Total Pipe Length
of factory charge
Additional
charge rule
Branch Maximum
pipe length
System Maximum
pipe length
Minimum pipe length
Unit
oz
ft
oz/ft
ft
ft
ft
ASH218JCDDA
60
50
0.2
65
98
10’ per indoor
ASH324JCDDA
67
100
82
197
ASH436JCDDA
90
131
82
230
ASH220NCDDA
69
66
82
165
ASH324NCDDA
82
100
82
197
ASH436NCDDA
102
131
82
230
ASH542JCDDA
113
164
82
262
Refrigerant Charge and Pipe Length Information