background image

Arize

®

 Factor 

Installation Guide

6

LED Driver Bracket Mount

LED Driver Suspended Mount

ML 900 LED Driver Mounting Option A Installation

After placing driver on mounting bracket, secure driver by tightening the screws shown.

Components required: GEHAK-NN-NE-N0 

Driver universal 1’ remote mount kit (95047411),

2 required.

Insert each toggle into the hole in the top of 

each driver bracket.

Wrap the two toggle cables around the support 

structure. Thread the toggle through the loop in 

each toggle cable.

Hang the driver from the support structure.

ML300 LED Driver Mounting Option A Installation

Support 

structure

8

1

3

2

4

Summary of Contents for Arize Factor

Page 1: ...longevity of the luminaire ensure that the lightbar and driver are clean and free of dirt dust oil or any other debris Do not apply any kind of film on the lens or otherwise cover the driver or light...

Page 2: ...77 347VAC 2 5 2A GEPSC210 600G AGJNA D17A1 NEMA L7 15P 3 48 kg 7 33lbs 277 VAC 2 5A Product Code Detailed Description Weight Series Load per Driver System Watts per Lightbar GEHF HPKRW1 ML900 PKR 2 6...

Page 3: ...etween Lightbars 15 Mounting Accessories SKU Description Detailed Description Weight 95051690 GEMB BANE Factor suspended mount wireform support 0 012 kg 0 026lbs 95051689 GEMB BAW1 Factor rolling rack...

Page 4: ...wo screws located at each end of the bracket After the horizontal bracket is attached to the strut secure the bracket to the struts by tightening the two screws located each end of the bracket ML300 R...

Page 5: ...Series lightbar can suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar A Adjust screws to le...

Page 6: ...he screws shown Components required GEHAK NN NE N0 Driver universal 1 remote mount kit 95047411 2 required Insert each toggle into the hole in the top of each driver bracket Wrap the two toggle cables...

Page 7: ...be secured such that it does not touch the light bar Shorting Cap Installation ML900 Electrical Connection 2 Lightbars only ML 300 Electrical connection 4 5 or 6 Lightbars only For all configurations...

Page 8: ...e key guides from Male to Female connector Driver Output and Lightbar Electrical Connections Connection Schematic 1 2 DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED Driver Input Wir...

Page 9: ...Replacement Ensure gasket is sitting in place on the inner edge of the junction box cover Fasten all 6 screws to ensure water tight seal NOTE Be careful not to strip out the junction box enclosure by...

Page 10: ...dress these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on are aware of these risks and that appropriate safeguards are in place Ces aver...

Reviews: