background image

Safety 

Instructions

Operating 

Instructions

Care 

and 
Cleaning

Troubleshooting 

Tips

Consumer 

Support

27

Vertical Zoneline Warranty.

n

  

Service trips to your site to teach you how to use 

the product.

n

 

 Improper installation, delivery or maintenance.

n

 

 If you have an installation problem, or if the air 

conditioner is of improper cooling or heating capacity 

for the intended use, contact your dealer or installer. 

You are responsible for providing adequate electrical 

connecting facilities.

n

  

In commercial locations, labor necessary to move 

the unit to a location where it is accessible for service 

by an individual technician.

n

  

Failure or damage resulting from corrosion due 

to installation in an environment containing corrosive 

chemicals.

n

  

Replacement of fuses or resetting of circuit breakers.

n

 

Filters.

n

 

 Failure of the product resulting from modifications 

to the product or due to unreasonable use including 

failure to provide reasonable and necessary 

maintenance.

n

  

Failure or damage resulting from corrosion due 

to installation in a coastal environment, except  

for models treated with special factory-applied  

anti-corrosion protection as designated  

in the model number.

n

 

 Damage to product caused by improper power supply 

voltage, accident, fire, floods or acts of God.

n

 

 Incidental or consequential damage caused 

by possible defects with this air conditioner.

n

  

Damage caused after delivery.

n

  

Product not accessible to provide required service.

What GE Will Not Cover:

This warranty is extended to the original purchaser and any succeeding owner for products purchased  

for use within the USA and Canada. If the product is located in an area where service by a GE Authorized 

Servicer is not available, you may be responsible for a trip charge or you may be required to bring  

the product to an Authorized GE Service location for service. In Alaska, the warranty excludes  

the cost of shipping or service calls to your site.
Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages.  

This warranty gives you specific legal rights, and you may also have other rights which vary from state  

to state or province to province. To know what your legal rights are, consult your local, state or provincial 

consumer affairs office or your state’s Attorney General.

Warrantor: General Electric Company. Louisville, KY 40225

For The Period Of:

GE Will Replace:

One Year

 

Any part

 of the Zoneline which fails due to a defect in materials or workmanship. During this 

From the date of the

limited one-year warranty

, GE will also provide, 

free of charge,

 all labor and related service 

original purchase

 

to replace the defective part.

Five Years

Any part of the sealed refrigerating system 

(the compressor, condenser, evaporator 

From the date of the

 

and all connecting tubing) which fails due to a defect in materials or workmanship.

original purchase

During this 

four-year limited additional warranty

, GE will also provide, 

free of charge

all labor and related service to replace the defective part.

Five Years

For the 

second through the fifth year

 from the date of original purchase, GE will replace 

From the date of the

 

certain parts

 that fail due to a defect in materials or workmanship. Parts covered are fan 

original purchase 

motors, switches, thermostats, electric resistance heater, electric resistance heater protectors, 

compressor overload, solenoids, circuit boards, auxiliary controls, thermistors, frost controls,  

ICR pump, capacitors, varistors and indoor blower bearing. During this 

four-year limited 

additional warranty

, you will be responsible for any labor or on-site service costs.

All warranty service provided by our Factory Service Centers, or an 

authorized Customer Care

®

 technician. To schedule service, on-line, visit 

us at GEAppliances.com, or call 800.GE.CARES (800.432.2737). For service 

in Canada, contact Gordon Williams Corp. at 1.888.209.0999. Please have 

serial number and model number availa ble when calling for service.

Staple your receipt here.  

Proof of the original purchase 

date is needed to obtain service 

under the warranty.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this Limited Warranty. 

Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited  

to one year or the shortest period allowed by law.

Summary of Contents for Appliances Zoneline 8500 series

Page 1: ...and Heat Pump Models 8500 Series Owner s Manual and Installation Instructions GEAppliances com Zoneline Vertical Printed in China Write the model and serial numbers here Model ________________________...

Page 2: ...th or at either the plug or connector end n Product must be operated with the electrical plug supplied with the product Do not replace the electrical plug supplied with the product n If the receptacle...

Page 3: ...if present NOTE The owner is responsible for setting the appropriate dip switches and connecting terminals Controls Dip Switches Dip Switches All Electric Heat Heat pump models only When this switch i...

Page 4: ...usly Occupancy Sensor Field Supplied When this switch is enabled UP it allows the unit to utilize an infrared motion sensor and a door switch for occupancy detection This feature combined with field d...

Page 5: ...to select the cooling limits The next three switches are used to control the heating limits Temperature limiting during COOL mode all temperatures shown in F UP DOWN Minimum Maximum NONE 1 2 3 60 85 1...

Page 6: ...Zoneline operation No common busing is permitted A separate wire pair must be run from each separate controlling switch to each individual Zoneline Room Air Sensor Requires room air sensor kit RAVRMS...

Page 7: ...ogether to automatically cycle the unit between normal and energy management operations Central Desk Control When connected the unit lock out is released and it can be turned ONor OFF with a switch lo...

Page 8: ...ructions Other features of your Zoneline About Heat Pumps on some models Heat pumps can reduce operating costs by exchanging heat from the outside air even when the outside temperature is below freezi...

Page 9: ...e filter at least every 30 days Air Filters The most important thing you can do to maintain the Zoneline is to change the filter at least every 30 days Dirty filters reduce cooling heating and air flo...

Page 10: ...led by a qualified electrician Follow the National Electrical Code NEC and or local codes and ordinances For personal safety this Zoneline unit and case must be properly grounded Protective devices fu...

Page 11: ...ordance with the NEC and local codes ordinances and regulations Power supply kit Recommended branch circuit wire sizes Nameplate maximum circuit AWG Wire breaker size size 15A 14 20A 12 30A 10 AWG Ame...

Page 12: ...TION CHART on page 13 to select the appropriate kit It is the responsibility of the installer to ensure the connection of components is done in accordance with electrical codes Direct connection to br...

Page 13: ...240 VAC When connecting the Zoneline to a single phase circuit for 230V applications Connect the white and black leads of the Zoneline power supply kit to the branch circuit L1 and L2 leads The white...

Page 14: ...12 D x 193 4 W x 32 H RAVWP15 15 D x 193 4 W x 32 H Cutout Dimensions 20 W x 321 4 H Access Panel with Return Air Grille RAVRG1 Return Air Grille RAVRG2 Cutout Dimensions 28 W x 48 H Cutout Dimensions...

Page 15: ...Filter bracket Secure platform to the floor Platform 231 4 x 231 4 square Min load capacity 175 lbs 4 min from front of case Unit installed through FRONT of case 5 min from front of case Unit installe...

Page 16: ...epth 231 8 D Case height 31 E Condensate drains 3 4 connector Primary Drain Centerline of cutout is approximately 51 4 from left case wall and 81 2 from back case wall Secondary Drain Centerline of cu...

Page 17: ...the option that best suits your installation requirements Follow the Installation Instructions provided with the return air grille accessory for installation details NOTE Use only one filter in the in...

Page 18: ...4 W x 32 H RAVWP12 12 D x 193 4 W x 32 H RAVWP15 15 D x 193 4 W x 32 H 2 Make drain hole cutout s Primary Drain Centerline of drain is approximately 51 4 from left platform edge and 81 2 from back pl...

Page 19: ...Flex duct can collapse and cause airflow restrictions Do not use flex duct for 90 bends or unsupported runs of 5 ft or more 3 Installation Instructions Your airflow should be balanced based on many f...

Page 20: ...the unit to be slid into the case 2 Ground the unit to the case by installing the front case to unit hex bolt and discard the two case to unit side screw 5a Hex bolt Air discharge outlet Rigid ductwo...

Page 21: ...tions as appropriate of this manual for proper connections 3 Replace the case front panel by replacing the four front screws and the two top screws 6 Installation Instructions Thermostat Unit Connecti...

Page 22: ...at connections 3 Raise the top duct by turning all four case top duct adjusting screws counterclockwise 4 Remove the front and or side case to unit grounding screw if present 5 Slide the unit out of t...

Page 23: ...ve a minimum of 65 free area Non GE grilles may be too restrictive for proper performance Consult your salesperson for assistance The air filter is dirty Change the filter at least every 30 days See t...

Page 24: ...el is set at fan cycle up This will cause the fan to cycle on and off with the compressor You may also hear a fan noise stop and start You may notice a few minutes delay in starting if you try to rest...

Page 25: ...Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Notes GEAppliances com 25...

Page 26: ...Notes 26 Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions...

Page 27: ...and you may also have other rights which vary from state to state or province to province To know what your legal rights are consult your local state or provincial consumer affairs office or your stat...

Page 28: ...t our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories GEAppliances com Individuals qualified to service their own appliances can have parts or access...

Reviews: