background image

11

Installation Instructions

ELECTRICAL REQUIREMENTS

230/208 VOLT  

ELECTRICAL SUPPLY

Tandem

15 Amp

230/208 volt receptacle configuration

Perpendicular

20 Amp

Large Tandem

30 Amp

  •   Use ONLY the wiring size recommended for single 

outlet branch circuit.

  •   Proper current protection is the responsibility  

of the owner.

A power supply kit must be used to supply power  

to the Zoneline unit. The appropriate kit is determined  

by the voltage, the means of electrical connection  

and the amperage of the branch circuit. See the 

POWER CONNECTION CHART on page 13 to select the 

appropriate kit.

 

All wiring, including installation of the receptacle,  

must be in accordance with the NEC and local codes, 

ordinances and regulations.

Power supply kit

Recommended branch circuit wire sizes*

 

Nameplate 

 

 

maximum circuit  

AWG Wire 

 

 

breaker size 

size**

 

15A 

14 

 

20A 

12 

 

30A 

10

    AWG –  American Wire Gauge 
    *  Single circuit breaker from main box 
 

**  Based on copper wire, single insulated conductor at 60° C

NOTE: 

Use copper conductors only.

 

FOR 230/208 VOLT CORD 

CONNECTIONS ONLY

    1.   Remove the front panel by taking out the four  

front screws, the upper two screws from the top  

of the panel and the shipping screws on each side,  

if present. (Discard the four side shipping screws,  

if present.)

    2.   Remove the junction box cover and the junction box 

and discard. 

 

3.   Connect the power cord, with a loop, through  

the strain relief.

Strain relief

IMPORTANT:

Power cord must 

have a loop.

Remove 

junction box 

and cover

Side 

shipping 

screw

Side 

shipping 

screw

Summary of Contents for Appliances Zoneline 8500 series

Page 1: ...and Heat Pump Models 8500 Series Owner s Manual and Installation Instructions GEAppliances com Zoneline Vertical Printed in China Write the model and serial numbers here Model ________________________...

Page 2: ...th or at either the plug or connector end n Product must be operated with the electrical plug supplied with the product Do not replace the electrical plug supplied with the product n If the receptacle...

Page 3: ...if present NOTE The owner is responsible for setting the appropriate dip switches and connecting terminals Controls Dip Switches Dip Switches All Electric Heat Heat pump models only When this switch i...

Page 4: ...usly Occupancy Sensor Field Supplied When this switch is enabled UP it allows the unit to utilize an infrared motion sensor and a door switch for occupancy detection This feature combined with field d...

Page 5: ...to select the cooling limits The next three switches are used to control the heating limits Temperature limiting during COOL mode all temperatures shown in F UP DOWN Minimum Maximum NONE 1 2 3 60 85 1...

Page 6: ...Zoneline operation No common busing is permitted A separate wire pair must be run from each separate controlling switch to each individual Zoneline Room Air Sensor Requires room air sensor kit RAVRMS...

Page 7: ...ogether to automatically cycle the unit between normal and energy management operations Central Desk Control When connected the unit lock out is released and it can be turned ONor OFF with a switch lo...

Page 8: ...ructions Other features of your Zoneline About Heat Pumps on some models Heat pumps can reduce operating costs by exchanging heat from the outside air even when the outside temperature is below freezi...

Page 9: ...e filter at least every 30 days Air Filters The most important thing you can do to maintain the Zoneline is to change the filter at least every 30 days Dirty filters reduce cooling heating and air flo...

Page 10: ...led by a qualified electrician Follow the National Electrical Code NEC and or local codes and ordinances For personal safety this Zoneline unit and case must be properly grounded Protective devices fu...

Page 11: ...ordance with the NEC and local codes ordinances and regulations Power supply kit Recommended branch circuit wire sizes Nameplate maximum circuit AWG Wire breaker size size 15A 14 20A 12 30A 10 AWG Ame...

Page 12: ...TION CHART on page 13 to select the appropriate kit It is the responsibility of the installer to ensure the connection of components is done in accordance with electrical codes Direct connection to br...

Page 13: ...240 VAC When connecting the Zoneline to a single phase circuit for 230V applications Connect the white and black leads of the Zoneline power supply kit to the branch circuit L1 and L2 leads The white...

Page 14: ...12 D x 193 4 W x 32 H RAVWP15 15 D x 193 4 W x 32 H Cutout Dimensions 20 W x 321 4 H Access Panel with Return Air Grille RAVRG1 Return Air Grille RAVRG2 Cutout Dimensions 28 W x 48 H Cutout Dimensions...

Page 15: ...Filter bracket Secure platform to the floor Platform 231 4 x 231 4 square Min load capacity 175 lbs 4 min from front of case Unit installed through FRONT of case 5 min from front of case Unit installe...

Page 16: ...epth 231 8 D Case height 31 E Condensate drains 3 4 connector Primary Drain Centerline of cutout is approximately 51 4 from left case wall and 81 2 from back case wall Secondary Drain Centerline of cu...

Page 17: ...the option that best suits your installation requirements Follow the Installation Instructions provided with the return air grille accessory for installation details NOTE Use only one filter in the in...

Page 18: ...4 W x 32 H RAVWP12 12 D x 193 4 W x 32 H RAVWP15 15 D x 193 4 W x 32 H 2 Make drain hole cutout s Primary Drain Centerline of drain is approximately 51 4 from left platform edge and 81 2 from back pl...

Page 19: ...Flex duct can collapse and cause airflow restrictions Do not use flex duct for 90 bends or unsupported runs of 5 ft or more 3 Installation Instructions Your airflow should be balanced based on many f...

Page 20: ...the unit to be slid into the case 2 Ground the unit to the case by installing the front case to unit hex bolt and discard the two case to unit side screw 5a Hex bolt Air discharge outlet Rigid ductwo...

Page 21: ...tions as appropriate of this manual for proper connections 3 Replace the case front panel by replacing the four front screws and the two top screws 6 Installation Instructions Thermostat Unit Connecti...

Page 22: ...at connections 3 Raise the top duct by turning all four case top duct adjusting screws counterclockwise 4 Remove the front and or side case to unit grounding screw if present 5 Slide the unit out of t...

Page 23: ...ve a minimum of 65 free area Non GE grilles may be too restrictive for proper performance Consult your salesperson for assistance The air filter is dirty Change the filter at least every 30 days See t...

Page 24: ...el is set at fan cycle up This will cause the fan to cycle on and off with the compressor You may also hear a fan noise stop and start You may notice a few minutes delay in starting if you try to rest...

Page 25: ...Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Notes GEAppliances com 25...

Page 26: ...Notes 26 Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions...

Page 27: ...and you may also have other rights which vary from state to state or province to province To know what your legal rights are consult your local state or provincial consumer affairs office or your stat...

Page 28: ...t our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories GEAppliances com Individuals qualified to service their own appliances can have parts or access...

Reviews: