background image

Consumer Support

Troubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

4

About the controls on the air conditioner.

Features and appearance will vary.

Controls

Mode Controls

HIGH COOL, MED COOL

and 

LOW COOL

provide

cooling with different fan speeds.

LOW FAN

or 

HIGH FAN

provides air circulation

and filtering without cooling.

NOTE: 

If you move the switch from a cool setting to 

OFF

or to

a fan setting, wait at least 3 minutes before switching back to
a cool setting.

Cooling Descriptions

For Normal Cooling

—Select 

HIGH COOL

or 

MED

COOL

with the temp control at midpoint.

For Maximum Cooling

—Select 

HIGH COOL

with the

temp control at the highest number available on

your knob.

For Quieter & Nighttime Cooling

—Select 

LOW COOL

with the temp control at midpoint.

Temp Controls

The temp control is used to maintain the

room temperature. The compressor will cycle

on and off to keep the room at the same level

of comfort. When you turn the knob to a

higher number the indoor air will become

cooler. Turn the knob to a lower number and

the indoor air will become warmer.

MODE CONTROLS

Your model will have one of the above type controls. 

TEMP CONTROLS

Your model will have one of the above type controls. 

OFF

LOW

FAN

LOW

COOL

HIGH

FAN

HIGH

COOL

MED

COOL

OFF

LOW

FAN

LOW

COOL

HI

FAN

HI

COOL

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

1

2

3

4

5

6

OFF

LOW

FAN

LOW

COOL

HI

FAN

HI

COOL

MED COOL

Summary of Contents for Appliances ASP05

Page 1: ...e Wall Installation Optional 12 Window Installation 8 11 Troubleshooting Tips 13 Normal Operating Sounds 13 Consumer Support Consumer Support Back Cover Product Registration 17 18 Warranty 19 49 7399 JR 10 00 ASP05 ASV05 AST05 AST06 Air Conditioners Owner s Manual Installation Instructions www GEAppliances com Write the model and serial numbers here ______________________________ _________________...

Page 2: ... in the vicinity of this or any other appliance SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazar...

Page 3: ... made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug...

Page 4: ...nt For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls The temp control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the indoor air w...

Page 5: ...ontal louvers adjusts the air direction up or down OR Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions 5 www GEAppliances com Additional controls and important information Vent Control on some models To open the vent push the lever to the right To close it push it to the left Air Direction Side to Side On some models the side to side air di...

Page 6: ...and pull it down To remove on some models 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water and a mi...

Page 7: ...e power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you pla...

Page 8: ...cordion panel Foam top window gasket Window sash seal Left accordion panel Type B 8 Window Installation Instructions 8 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Air conditioner Top mounting rail seal strip ...

Page 9: ...than the top of the storm window frame Attach securely with nails or screws provided by the installer 2 Read completely then follow step by step Window Requirements These instructions are for a standard double hung window You will need to modify them for other types of windows The air conditioner can be installed without the accordion panels if needed to fit in a narrow window See the window openi...

Page 10: ...bracket on each side Tighten the screws to secure the brackets in place Insert the frames of the accordion panels into the top and bottom mounting rails Attach the accordion panels to the side of the case using 6 type A screws B A 3 10 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Window Installation Instructions C Top mounting rail Bott...

Page 11: ...bout a 1 3 bubble will be the correct case slant to the outside Extend the left and right accordion panels to the vertical window sashes and attach with 4 type B screws Attach the top mounting rail to the sash with a type B screw Attach the brackets to the stool on both sides using two type B screws C B A Install the Security Bracket and the Foam Top Window Gasket Attach a security bracket with a ...

Page 12: ...e certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and secure with 12 1 long 10 wood screws NOTE Drill pilot holes if necessary for proper installation If the frame is oversized use shims to prevent case distortion C B A 1 The case may be installed through the wall in both existing and new construction...

Page 13: ...o prevent tripping of the compressor overload Air conditioner does Airflow is restricted Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may Turn the temperature knob to a higher number not be set correctly The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The r...

Page 14: ...14 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes ...

Page 15: ...15 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes ...

Page 16: ...16 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes ...

Page 17: ...otection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all y...

Page 18: ...uct detach and return the form below to ensure that your product is registered or register online at www GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe ...

Page 19: ... to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God ...

Page 20: ...nts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Di...

Reviews: