![background image](http://html.mh-extra.com/html/ge/ame18/ame18_use-and-care-and-installation-manual_2198672004.webp)
Operating Your Air Conditioner Controls
FAN
MED
ONLY
COOL
OFF=
SELECTOR
Selector Switch
OFF turns air conditioner off.
FAN ONLY provides
circulation without cooling.
Fan
Switch
in
NORMAL
LO COOL provides cooling with
low fan speed operation.
MED COOL provides cooling
with medium fan speed operation.
HI COOL provides cooling with
high fan speed operation.
THERMOSTAT
2 3 4 5 6 7 8 910
■
-w-n-n-m-m-n-n-m-m
❑
Thermostat Control
When you move the Thermostat
Control to the desired setting, the
thermostat will
control
the temperature
the indoor air.
The higher the number selected, the
cooler the indoor air
become.
Energy Saver Fan
Cycle Switch
This switch
controls the
operation.
NORMAL
setting allows
Freezing up
continuous
fan function,
circulating air
even when the
compressor has
cycled off and
the thermostat
setting has been
ENERGY SAVER
SAVE
This
Outside air
setting is
recommended for
temperature
maximum comfort.
dropping
SAVE setting
the fan cycle on
and off with the compressor during
cooling. The fan stops when the
If
notice that your air
setting is-satisfied. This
conditioner is not-cooling as it
setting results in
off time
should, it may be that ice has formed
and wider variations of room
on the cooling coils. The ice blocks
temperature and humidity. This
air flow and stops the unit from
setting is normally used when the
cooling the room. This “freezing up”
room is unoccupied.
is a temporary condition that most
often occurs at night when the
Thermostat is set at a higher number
and the Selector is set on LO COOL.
To correct the condition, set the
Selector at HI FAN or HI COOL
move the Thermostat to the
warmest setting.
4
TIMER
Timer Control
(on models so equipped)
When you turn the Timer Control
to the MANUAL setting, the air
conditioner starts immediately and
operates continuously if the
Selector Switch is at any setting
other than OFF.
When used with the
Switch, the Timer
Control turns the air conditioner
on or off at preset times.
To delay the start of the air
conditioner anywhere from
1 to 12 hours:
1. Set the Timer Control for the
number of hours you want to delay
the start of the air conditioning
operation.
2. Set the Delay
Switch
at DELAY START.
3. Turn the
Selector Switch to
—
the desired setting.
DELAY START
DELAY STOP
To stop the air conditioning from
1 to 12 hours later:
1. Set the Timer Control for the
number hours you want the air ‘
conditioner to operate before
shutting off automatically.
2. Set the Delay
Switch at
DELAY STOP.
3. Turn the Selector Switch to the
desired setting.