background image

49-5000437  Rev. 2

15

LIMITED W

ARRANTY

GE Appliances Air Conditioner

 - One-Year Limited Warranty

EXCLUSION OF IMPLIED WARRANTIES - Your sole and exclusive remedy is product repair as provided in this Limited 
Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, 
are limited to one year or the shortest period allowed by law.

For US Customers: This limited warranty is extended to the original purchaser and any succeeding owner for products 
purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized 
Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized 
GE Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your 
home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty gives you 
specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, 
consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor US:  

GE Appliances, Haier company 

Louisville KY 40225

Ŷ

  Customer instruction. This owner’s manual provides 

information regarding operating instructions and  user 

controls.

Ŷ

  Improper installation. If you have an installation problem, 

or if the air conditioner is of improper capacity, contact 

your dealer or installer.  You are responsible for providing 

adequate electrical connecting facilities.

Ŷ

  Failure of the product resulting from modifications to the 

product or due to unreasonable use including failure to 

provide reasonable and necessary maintenance.

Ŷ

  Replacement of house fuses or resetting of circuit breakers.

Ŷ

  Failure due to corrosion on models not corrosion-protected.

Ŷ

  Damage to the product caused by improper power supply 

voltage, accident, fire, floods or acts of God.

Ŷ

 Incidental or consequential damage caused by possible 

defects with this air conditioner.

Ŷ

  Damage caused after delivery.

What Will Not Cover:

For The Period Of:

Will Replace:

One Year

From the date of the 

original purchase

Replacement, repair, or refund of the original retail price for any product which fails due 

to a defect in materials or workmanship.  If the unit is exchanged, the replacement unit 

is warranted for the remainder of your product’s original one-year warranty period.  GE 

Appliances will, at its sole discretion, replace the product with a product of the same or 

comparable functionality and quality or refund the original retail price.

Ŷ

 

 Properly pack your unit. We recommend using the original 

carton and packing materials.

Ŷ

Return the product to the retail location where it was 

purchased.

Ŷ

  Include in the package a copy of the sales receipt or other 

evidence of date of original purchase. Also print your name 

and address and a description of the defect.

In Order to Make a Warranty Claim During the First 90 Days from the Date of Original Purchase:

Ŷ

  Locate your original sales receipt and make a note  of your 

model and serial number.

Ŷ

 Call  866.907.1655

 (in the United States)

 to initiate the 

product replacement process. 

Ŷ

You will be asked to provide your name, address, date of 

purchase, model and serial number.

Ŷ

GE Appliances will arrange for a carton to be sent to your 

home to recover the product.

Ŷ

  

Please return all requested materials (postage pre-paid) 

in the carton provided.  Please include a description of the 

defect.

Ŷ

You should receive your replacement product or refund 

within 7 to 10 business days after your package is received. 

In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty: 

Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty.

Summary of Contents for AKQ06

Page 1: ...neral Electric Company Manufactured under trademark license OWNER S MANUAL AND INSTALLATION INSTRUCTIONS AIR CONDITIONER Room 49 5000437 Rev 2 01 22 GEA SAFETY INFORMATION 3 USING THE AIR CONDITIONER Controls 5 CARE AND CLEANING Air Filter 8 Outdoor Coils 8 INSTALLATION INSTRUCTIONS 9 TROUBLESHOOTING TIPS 14 Normal Operating Sounds 15 LIMITED WARRANTY 17 CONSUMER SUPPORT 18 AKQ06 ...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...cinity of this or any other appliance Ŷ If the receptacle does not match the plug the receptacle must be changed out by a qualified electrician Ŷ R QRW XVH PHDQV WR DFFHOHUDWH WKH GHIURVWLQJ SURFHVV or to clean other than those recommended by the manufacturer Ŷ The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance...

Page 4: ... contact a qualified service technician Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded Where a 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 prong wall outlet The air conditioner should always be plugged into its own individual electrical outlet wh...

Page 5: ...e user interface on the unit will then illuminate for 5 seconds when any button is pressed on the user interface or on the remote control Press the Display pad on the remote control again the display on the unit will revert back to the default behavior Temp Increase Decrease Pads 8VH WR FKDQJH WKH WHPSHUDWXUH VHWWLQJ XS RU down Press or hold either the Increase Decrease pads until the desired temp...

Page 6: ... speed to AUTO In COOL mode the fan will stay in the AUTO speed setting for 8 hours from the time the SLEEP mode pad was pressed The air conditioner will also raise the set point 2 F in 30 minutes and 2 F more in another 30 minutes where it will remain for the next 7 hours After 8 hours the air conditioner will resume the settings that were in place before the SLEEP mode pad was pressed While the ...

Page 7: ...t provide cooling a Set temperature cannot be entered The room temperature will appear in the display Dry Mode In this mode the air conditioner will generally operate in the form of a dehumidifier Since the conditioned space is a closed or sealed area some degree of cooling will continue On Dry mode the fan speed is controlled at Low automatically Auto Mode KHQ RX VHW WKH DLU FRQGLWLRQHU LQ 872 PR...

Page 8: ...te the air conditioner without a filter because dirt and lint will clog it and reduce performance Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water and a mild detergent Do not use bleach or abrasives Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or s...

Page 9: ...60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet TOOLS YOU WILL NEED CAUTION Do not under any circumstances cut or remove the third ground ...

Page 10: ...panel Foam top window gasket Left accordion panel Top mounting rail and seal strip Air conditioner PARTS INCLUDED Appearance may vary Window sill and sash seal Type A 4 VFUHZV Type B 7 RU VFUHZV Frame lock 2 For wooden windows Sash lock 1 Frame Lock 2 For Vinyl Clad windows on some models ...

Page 11: ...ow frame THICKNESS To determine the thickness place D SLHFH RI ZRRG RQ WKH VLOO WR PDNH LW Ǝ KLJKHU than the top of the storm window frame or the vinyl frame Attach securely with nails or screws provided by the installer PLQ With accordion panels Ǝ KLJKHU than storm window frame Storm window frame Wood Sill Ǝ KLJKHU than vinyl frame on some windows Vinyl frame 3 PREPARE THE AIR CONDITIONER A Insta...

Page 12: ...DOW Cont C Place the Frame lock between the frame extensions and the window sill as shown 4 PREPARE THE WINDOW Cut the window seal 2 long strips to the proper length Peel off the backing and attach the seal to the underside of the window sash Sealing Strip with adhesive 6 INSTALL SASH LOCK AND FOAM TOP WINDOW GASKET A CAUTION To prevent broken glass or damage to windows on vinyl or other similarly...

Page 13: ... the temperature knob to a higher number The air filter is dirty Clean the filter at least every 30 days See the Care and Cleaning section The room may have been hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace registers and cold air returns Cooling coils have iced up See Air conditioner freezing up below A...

Page 14: ...Ŷ DWHU ZLOO FROOHFW LQ WKH EDVH SDQ GXULQJ KLJK KXPLGLW or on rainy days The water may overflow and drip from the outdoor side of the unit Ŷ 7KH IDQ PD UXQ HYHQ ZKHQ WKH FRPSUHVVRU GRHV QRW Ŷ DWHU GURSOHWV EHLQJ WKURZQ DJDLQVW WKH RXWVLGH coils can make a pinging noise This helps cool the condenser You can reduce this noise by opening the water hole seal located on the lower right side of the unit...

Page 15: ...ymaintenance Ŷ Replacementofhousefusesorresettingofcircuitbreakers Ŷ Failureduetocorrosiononmodelsnotcorrosion protected Ŷ Damagetotheproductcausedbyimproperpowersupply voltage accident fire floodsoractsofGod Ŷ Incidentalorconsequentialdamagecausedbypossible defectswiththisairconditioner Ŷ Damagecausedafterdelivery What Will Not Cover For The Period Of Will Replace One Year From the date of the or...

Page 16: ...DFNLQJ PDWHULDO Q WKH 86 GEAppliances com register Parts and Accessories Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day Q WKH 86 GEApplianceparts com or by phone at 877 959 8688 during normal business hours Instructions contained in this manual co...

Page 17: ...mpany Fabricado bajo licencia de marca MANUAL DEL PROPIETARIO Y INSTRUCCIONES DE INSTALACIÓN 49 5000437 Rev 2 01 22 GEA INSTRUCCIONES DE SEGURIDAD 3 USO DEL ACONDICIONADOR DE AIRE Controle 5 CUIDADO Y LIMPIEZA Filtro de aire 8 Bobinas para exteriores 8 INSTRUCCIONES DE INSTALACIÓN 9 SOLUCIONAR PROBLEMAS 14 Sonidos de operación normales 15 GARANTÍA LIMITADA 17 SERVICIO AL CONSUMIDOR 18 AKQ06 ACCOND...

Page 18: ...s y creemos que usted también Entre otras cosas el registro de su electrodoméstico asegura que podamos entregarle información importante del producto y detalles de la garantía cuando los necesite Registre su electrodoméstico GE ahora a través de Internet Sitios Web y números telefónicos útiles están disponibles en la sección de Soporte para el Consumidor de este Manual del Propietario También pued...

Page 19: ...ro electrodoméstico Ŷ 6L HO UHFHSWiFXOR QR FRLQFLGH FRQ HO HQFKXIH HO FDPELR GHO mismo deberá ser realizado por un electricista calificado Ŷ ILQ GH DFHOHUDU HO SURFHVR GH GHVFRQJHODFLyQ R para limpiar no use ningún método que no sea el recomendado por el fabricante Ŷ VWH HOHFWURGRPpVWLFR GHEHUi VHU JXDUGDGR HQ XQD sala donde no haya fuentes de encendido continuas SRU HMHPSOR OODPDV DELHUWDV XQ HOH...

Page 20: ...ole el tomacorriente y el circuito eléctrico para asegurar que el enchufe esté correctamente conectado a tierra En caso de contar con un tomacorriente de pared de 2 cables es su responsabilidad y obligación reemplazarlo por un tomacorriente de pared de 3 cables correctamente conectado a tierra El acondicionador de aire debería estar siempre conectado a un enchufe específico con un índice de voltaj...

Page 21: ...drá automáticamente en cualquier WHPSHUDWXUD HQWUH 6L GHVHD que la pantalla lea la temperatura real de la sala consulte OD VHFFLyQ DQ 2QO 6yOR 9HQWLODGRU Fan Pad 3UHVLRQH OD WHFOD DQ 9HQWLODGRU SDUD VHOHFFLRQDU OD YHORFLGDG XWR XWRPiWLFD RZ DMD 0HG 0HGLD R LJK OWD GHO YHQWLODGRU DGD YH TXH OD WHFOD VH presiona el modo de velocidad del ventilador cambia En algunos modelos la velocidad del ventilado...

Page 22: ...HQWHV KRUDV XHJR GH KRUDV HO DFRQGLFLRQDGRU GH DLUH reanudará las configuraciones que fueron ajustadas antes de que se presionara la tecla del modo SLEEP RUPLU Mientras la unidad se encuentre en el modo SLEEP QDFWLYLGDG SUHVLRQDU OD WHFOD 6 3 QDFWLYLGDG nuevamente hará que regrese a las configuraciones que estaban en funcionamiento antes de que se presionara la WHFOD GHO PRGR 6 3 QDFWLYLGDG Tecla ...

Page 23: ...gresiva Es posible que usted necesite ajustar un tiempo nuevo si así lo desea Dirección del aire 8VH OD SDODQFD SDUD DMXVWDU OD GLUHFFLyQ GHO DLUH KDFLD OD izquierda y la derecha solamente Modo Seco En este modo el acondicionador de aire normalmente IXQFLRQDUi FRPR GHVKXPLGLILFDGRU HELGR D TXH HO HVSDFLR acondicionado es un área cerrada o sellada continuará KDELHQGR FLHUWR JUDGR GH UHIULJHUDFLyQ Q...

Page 24: ...ERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruirán y reducirán su rendimiento Cuidado y Limpieza Rejilla y caja Apague el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar 3DUD OLPSLDU XVH DJXD XQ GHWHUJHQWH VXDYH 1R XVH FORUR R materiales abrasivos Bobinas para exteriores Se deben inspeccionar con frecuencia las...

Page 25: ...usible GH GLODWDFLyQ GH WLHPSR GH DPSHULRV R XQ cortacircuitos El enchufe de tres púas con conexión a tierra minimiza la posibilidad de descargas eléctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad hacer que un técnico lo reemplace por uno de tres tomas con conexión a tierra Herramientas que necesitará PRECAUCIÓN DMR QLQJXQD FLUFXQVWDQFLD ...

Page 26: ...el de montaje superior y tira de sellado Acondicionador de aire Sello de la banda GH OD YHQWDQD Instrucciones de instalación PARTES INCLUIDAS Apariencia puede variar Tornillos de 7LSR 7RUQLOORV GH ô R ò 7LSR ORTXHR GHO PDUFR SDUD YHQWDQDV GH madera 3DVDGRU JLUDWRULR ORTXHR GHO PDUFR SDUD YHQWDQDV FRQ revestimiento de vinilo HQ DOJXQRV PRGHORV ...

Page 27: ... determinar el grueso coloque un SHGD R GH PDGHUD HQ HO XPEUDO SDUD KDFHUOD Ǝ PiV alta que la parte superior del marco de la ventana de tormentas o del marco vinilo Péguelo firmemente con clavos o con tornillos proporcionados por el instalador Ǝ PiV DOWR que el marco de ventana de tormentas Marco de ventana de tormentas Madera 8PEUDO Ǝ PDV DOWR TXH HO PDUFR YLQLOR HQ DOJXQDV YHQWDQDV Marco vinilo ...

Page 28: ... OD ORQJLWXG DSURSLDGD HVSHJXH OD SDUWH SRVWHULRU y pegue el sello a la parte inferior de la banda de la ventana 6 INSTALE EL PASADOR GIRATORIO Y LA JUNTA DE GOMAESPUMA DE LA PARTE SUPERIOR DE LA VENTANA A PRECAUCIÓN Para evitar la rotura de vidrios o daños sobre las ventanas sobre el vinilo u otras ventanas de construcción similar ajuste el pasador giratorio sobre la jamba lateral de la ventana c...

Page 29: ...o de aire está sucio LPSLH HO ILOWUR FDGD GtDV SRU OR PHQRV 9HU OD VHFFLyQ GH Cuidado y limpieza La habitación podría haber estado caliente Cuando el acondicionador de aire se enciende usted necesita darle tiempo para que enfrié la habitación El aire frío se está escapando Cerciórese de que los registros de la calefacción no están abiertos y se encuentran retornando el aire frío Las bobinas de enf...

Page 30: ...GH OD EDVH FXDQGR HO QLYHO de humedad sea alto o en días lluviosos Es posible que el agua se desborde y gotee desde el lado externo de la unidad Ŷ V SRVLEOH TXH HO YHQWLODGRU FRQWLQ H IXQFLRQDQGR LQFOXVR cuando el compresor no esté en funcionamiento Ŷ V SRVLEOH TXH ODV JRWLWDV GH DJXD DUURMDGDV FRQWUD ODV bobinas externas produzcan un ruido metálico Esto ayuda a enfriar el condensador Este ruido s...

Page 31: ...roductocomoresultadodemodificaciones sobreelmismoodebidoaunusoirrazonable incluyendo lafaltademantenimientorazonableonecesario Ŷ Reemplazodefusiblesdelhogaroreiniciodedisyuntores Ŷ Fallascomoconsecuenciadecorrosiónenmodelossin proteccióncontraésta Ŷ Dañosocasionadossobreelproductopornivelde suministrodevoltajeinadecuado accidente incendio inundacionesocatástrofesnaturales Ŷ Dañosconsecuentesoincid...

Page 32: ...o Q 88 GEAppliances com register Piezas y Accesorios Aquellos individuos calificados para realizar el servicio técnico de sus propios electrodomésticos podrán solicitar el envío de SLH DV R DFFHVRULRV GLUHFWDPHQWH D VXV KRJDUHV VH DFHSWDQ ODV WDUMHWDV 9 6 0DVWHU DUG LVFRYHU 2UGHQH KR D WUDYpV GH QWHUQHW GXUDQWH ODV KRUDV WRGRV ORV GtDV Q 88 GEApplianceparts com R GH IRUPD WHOHIyQLFD DO GXUDQWH el ...

Reviews: