INST

ALLA

TION INSTRUCTIONS

Installation Instructions

Security Brackets Installation
(It is important to install these brackets 

to prevent the chassis from being 

pushed into the room from the outside.)

Ŷ

The brackets must be installed so the flanges are 
hooked behind the inside flanges of the wall sleeve. 

8VLQJWKHVFUHZVSURYLGHGDWWDFKWKHEUDFNHWVRQ

the sides of the chassis. 

To install the security bracket without fully removing 
the front grille:
1.  Grasp the front grille louvers on both sides at the 

recess and pull forward.

2.  Remove the filter by pulling forward and out.
3.  Remove the two Phillips head screws located in 

the upper corners of the grille louver opening. Do 
not discard screws.

4.  Grasp the left and right rear edges of the front 

grille about 6” from the top and pull outward to 
release the tabs on the inside of the grille from 
the slots in each side of the metal chassis cover. 
When released pull out both bottom corners of the 

IURQWJULOOHDERXW´WRH[SRVHWKHWZRVFUHZKROHV

on the lower area of the metal chassis cover. 

5.  Locate the 2 metal brackets stamped 26” that were 

included with the air conditioner. Hook the short 
flange of the bracket behind the sleeve inside edge 
and rotate it so the long side can be pressed flat 
against the metal chassis cover. Adjust so the 
bracket can be secured to the metal chassis cover 
by 2 screws included with the bracket. Only one 
bracket will be needed and can be installed on 
either side of the chassis.

6.  To reinstall the front grille, push the lower corners 

to toward the sleeve until the side tabs click into 
the mating slots. Reinstall the two screws removed 
earlier and replace the filter and louvers. 

For 26” sleeves, hook the short flange of the 26” 
bracket behind the sleeve inside edge and secure 
to the unit with the two screws provided. Repeat 
on the opposite side.

Hook inside 

sleeve edge 

and secure 

to unit 

Hook inside 
sleeve edge 
and secure 
to unit 

Summary of Contents for AJCQ06LCH

Page 1: ...www GEAppliances com FRANÇAIS For a French version of this manual visit our Website at www GEAppliances ca Pour un version français de ce manuel d utilisation veuillez visiter notre site web à l adresse www GEAppliances ca SAFETY INFORMATION 3 USING THE AIR CONDITIONER 4 CARE AND CLEANING 7 INSTALLATION INSTRUCTIONS 8 TROUBLESHOOTING TIPS 17 CONSUMER SUPPORT Warranty 19 Consumer Support 20 OWNER S...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...ditioner HOW TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO NOT use an adapter plug with this appliance The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of elec...

Page 4: ... Mode 8VH WR VHW 22 7 RQ VRPH PRGHOV 5 872 or FAN modes Indicator lights on the controls will show the mode selected 4 Temp Increase Decrease Pads 8VH WR VHW WHPSHUDWXUH ZKHQ LQ XWR RRO U RU HDW on some models mode 5 Fan Speed 8VH WR VHW WKH IDQ VSHHG DW 2 0 80 25 872 QGLFDWRU OLJKWV ZLOO VKRZ WKH VSHHG VHOHFWHG 6 Timer ON 8VH WR VHW WKH DLU FRQGLWLRQHU WR DXWRPDWLFDOO WXUQ ON from 5 to 24 hours l...

Page 5: ...en the time of TIMER ON is displayed press the Timer button again the TIMER OFF indicator light illuminates It indicates the Auto Stop program is initiated Ŷ 3UHVV RU KROG WKH 83 RU 2 1 EXWWRQ WR FKDQJH WKH Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start Ŷ The selected time will register in 5 second...

Page 6: ...t To open the ventilation port pull the lever forward The lever will lock in place To replace the air discharge louvers reverse the above procedure Remote Wall Thermostat Heat Cool models only All heat cool models are capable of being controlled by a 24 VAC remote wall thermostat The thermostat control connection board is located behind a metal cover on the right side of the metal chassis cover To...

Page 7: ... from the user interface press the rear of the tab and gently pull apart Front Grille Re installation 1 Reconnect the multi pin low voltage connector 2 Before engaging the 4 tabs on the inside top of the grille align the ventilation lever on the chassis into the mating slot on the inside of the discharge opening in the grille After ensuring proper alignment of the ventilation lever push the grille...

Page 8: ...sing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician ELECTRICAL REQUIREMENTS Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this ai...

Page 9: ...e slots in each side of the metal chassis cover When released pull out both bottom corners of the IURQW JULOOH DERXW WR H SRVH WKH WZR VFUHZ KROHV on the lower area of the metal chassis cover 5 Locate the 2 metal brackets stamped 26 that were included with the air conditioner Hook the short flange of the bracket behind the sleeve inside edge and rotate it so the long side can be pressed flat again...

Page 10: ...vers for better air distribution Front of unit is blocked by drapes blinds furniture etc which restricts air distribution Clear blockage in front of unit Doors windows registers etc may be open Close doors windows registers Unit recently turned on in hot room Allow additional time to remove stored heat from walls ceiling floor and furniture Air conditioner turns on and off rapidly Dirty air filter...

Page 11: ...ZDUUDQW H FOXGHV WKH FRVW RI VKLSSLQJ RU VHUYLFH calls to your home 6RPH VWDWHV GR QRW DOORZ WKH H FOXVLRQ RU OLPLWDWLRQ RI LQFLGHQWDO RU FRQVHTXHQWLDO GDPDJHV 7KLV OLPLWHG ZDUUDQW gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General W...

Page 12: ...UFKDVH D SSOLDQFHV H WHQGHG ZDUUDQW DQG OHDUQ DERXW VSHFLDO GLVFRXQWV WKDW DUH DYDLODEOH ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty or call 800 626 2224 during normal business hours CONSUMER SUPPORT Parts and Accessories Individuals qualified to service t...

Reviews: