Instillation Instructions
these instructions with the appliance.
OWNER: Keep these instructions for future use.
Electrical
Please Read Carefully.
How to connect electricity
For personal safety, this
appliance must be properly
grounded.
Electrical requirement
models
require a
volt a.c., 60
grounded outlet
protected with a 15 amp time delay
fuse or circuit breaker.
The power cord on these models has
a three-prong (grounding) plug that
mates with a standard three-prong
(grounding) wall outlet (Fig. 1) to
minimize the possibility of electric
shock hazard from these appliances.
230/208-volt models
require their
own single branch circuit supplying
230/208-volt a.c., protected with a
time delay fuse or circuit breaker.
This is recommended for best
performance and to prevent
overloading house wiring circuits,
which could cause a possible fire
hazard from overheating wires.
The power cord on these models
has a 230/208-volt perpendicular,
tandem or large tandem type plug
that mates respectively with a
230/208-volt perpendicular,
tandem or large tandem type wall
outlet. These types of outlets are
available at most hardware stores.
PREFERRED
METHOD
Fig. 1
—
.
‘@q
.
INSURE PROPER
EXISTS BEFORE USE
Where a standard two-prong wall
outlet is encountered, it is your
MATCHING
PERPENDICULAR TYPE WALL OUTLET
LINE CORD PLUG
REQUIRES 20 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER PROTECTION
230/208-VOLT
MATCHING
TANDEM TYPE
WALL OUTLET
LINE CORD PLUG
REQUIRES 15 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER PROTECTION
\
●
230/208-VOLT
MATCHING
LARGE TANDEM TYPE
WALL OUTLET
LINE CORD PLUG
REQUIRES 30 AMP TIME
FUSE
OR CIRCUIT BREAKER PROTECTION
Whether your air conditioner is a
or a 230/208-volt unit, it
is important to have the wall
outlet and circuit checked by a
qualified electrician if there is
personal
and
any doubt as to whether a proper
to have it replaced with a properly
ground exists.
grounded three-prong wall outlet.
DO NOT,
OR
THIRD
PRONG FROM
POWER CORD.
8