background image

49-5000565   Rev. 0

9

INST

ALLA

TION INSTRUCTIONS

Installation Instructions

3.  PREPARE THE AIR 

CONDITIONER

A. 

Remove three screws on each side of the case, 

and two screws from the top. Save the screws 
for use later..

B.

 Insert a flat head screw driver between the front 

grille and the metal case along the sides. Gently 

pry the grille from the case.  

NOTE: 

Cover the flat head screw driver with 

tape to prevent scratching the case.

C.

 The front panel of the air conditioner is corded to 

the air conditioner.  They cannot be separated.

D.

 While one person holds the front panel, have a 

second person pull the air conditioner out of the 
case using the handle on the bottom front of the 
air conditioner.

E.

 The air conditioner is very heavy so make sure 

that it will be resting on a sturdy surface.

1.  WINDOW REQUIREMENTS

•  These instructions are for a standard 

double-hung window. You will need to modify 
them for other types of windows.

•  The air conditioner can be installed without the 

side curtain panels if needed to fit in a narrow 
window. See the window opening dimensions.

•  All supporting parts must be secured to firm 

wood, masonry or metal.

•  The electrical outlet must be within reach of 

the power cord.

•  Follow the dimensions in the table and 

illustration for your model.

2.  STORM WINDOW 

REQUIREMENTS

A storm window frame will not allow the air 
conditioner to tilt toward the outside, and will 
keep it from draining properly. To adjust for 
this, attach a piece of wood to the sill.

WOOD PIECES
WIDTH: 2

Ǝ

LENGTH: 

Long enough to fit inside the window 

frame.

THICKNESS: 

To determine the thickness, 

SODFHDSLHFHRIZRRGRQWKHVLOOWRPDNHLWƎ

higher than the top of the storm window frame 
or the vinyl frame.
Attach securely with nails or screws provided 
by the installer.

A

(With side curtain panels)

B

ƎKLJKHU

 

than storm 
window 
frame

Storm window 
frame

Wood

Sill

ƎKLJKHU

 

than vinyl frame  
(on some windows)

9LQ\OIUDPH

Models

A

B

AHSK24AA
AHFK18AA
AHFK24AA

´PLQ

´´

Front Panel  

or Grill

Case

Air  

Conditioner

Save these screws 

for later use.

Summary of Contents for AHSK24AAH1

Page 1: ...NFORMATION 3 USING THE AIR CONDITIONER Controls 4 Remote Control 5 Cool Mode 5 Energy Saver Mode 5 Air Direction 6 CARE AND CLEANING Grille and Case 6 Air Filter 6 Outdoor Coils 6 Install Batteries in...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...ndow Air Conditioner HOW TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO...

Page 4: ...l until the set time is zero 7 Sleep Pad set by air conditioner controls only The SLEEP mode sets the unit to gradually change settings over an 8 hour period to allow for some increased energy efficie...

Page 5: ...High or Med fan with a middle set temperature For Maximum Cooling Select the Cool mode and High fan with a lower set temperature For Quieter and Nighttime Cooling Select the Cool mode and Low fan wit...

Page 6: ...filter Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher CAUTION DO NOT operate the air conditioner without a filter beca...

Page 7: ...ding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong...

Page 8: ...Remote Control Top Mounting Rail may be installed already Foam Seal UDFNHW Screws 6 RRG Screws 8 ODW HDG ROW DQG Lock Nut 2 A B C D DELAY MODE ON OFF SPEED TEMP TIME TEMP TIME PARTS INCLUDED Appearanc...

Page 9: ...pes of windows The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm w...

Page 10: ...mounting rail if not already installed with four type A screws B Slide left hand curtain assembly into left end of top and bottom mounting rail Repeat for right hand curtain assembly C Fasten curtain...

Page 11: ...WKUHH W SH VFUHZV WR VHFXUH WKH FDVH WR the window sill Drill pilot holes if necessary Bottom rail Top rail Window sash SILL About RRG 6FUHZV RRG Screws 6 INSTALL OUTER CASE IN WINDOW D Thread nut ont...

Page 12: ...pe C screw to secure the window in place A B A Top of lower window sash B Foam seal 9LQ O Wood 8 RETURN CHASSIS TO THE OUTER CASE A Once the case is securely attached to the window reinstall the air c...

Page 13: ...e there are not curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set properly Turn the temperature control to a higher number The air filter is dirty...

Page 14: ...RSHUO LQVHUWHG This plug may be removed during operation to minimize water in the back of the unit however removing it will lower the efficiency of your unit NOTE Do not drill hole in the base pan Bas...

Page 15: ...s been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfere...

Page 16: ...16 49 5000565 Rev 0 Notes NOTES...

Page 17: ...t Cover 7KLV OLPLWHG ZDUUDQW LV H WHQGHG WR WKH RULJLQDO SXUFKDVHU DQG DQ VXFFHHGLQJ RZQHU IRU SURGXFWV SXUFKDVHG IRU KRPH XVH ZLWKLQ WKH 86 I WKH SURGXFW LV ORFDWHG LQ DQ DUHD ZKHUH VHUYLFH E D SSOLF...

Page 18: ...H ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended warranty or call 80...

Reviews: