background image

„

 

You may hear a pinging noise caused by 

water being picked up and thrown against the 

condenser on rainy days or when the humidity  

is high. This design feature helps remove 

moisture and improve efficiency.

„

You may hear the thermostat click when the 

compressor cycles on and off.

„

Water will collect in the base pan during 

high humidity or on rainy days. The water 

may overflow and drip from the outdoor side 

of the unit.

„

 

The fan may run even when the compressor  

does not.

Normal Operating Sounds

 

Troubleshooting Tips.

 GEAppliances.com

Problem 

Possible Causes 

What To Do

Air conditioner

 

The air conditioner

 

• Make sure the air conditioner plug is pushed 

does not start

 

is unplugged.

 

  completely into the outlet.

 

The fuse is blown/circuit

 

• Check the house fuse/circuit breaker box and replace 

 

breaker is tripped.

 

  the fuse or reset the breaker.

 

Power failure.

 

•The unit will automatically re-start in the settings last  

 

 

  used after the power is restored.

 

 

•There is a protective time delay (approximately   

 

 

 

  3 minutes) to prevent tripping of the compressor  

 

 

 

  overload. For this reason, the unit may not start  

 

 

 

  normal cooling for 3 minutes after it is turned    

 

  

back 

on.

 

The current interrupter

 • 

Press 

the 

RESET

 button located on the power cord plug.

 

device is tripped.

 • 

If 

the 

RESET

 button will not stay engaged, discontinue  

 

 

  use of the air conditioner and contact a qualified  

  

 

service 

technician.

Air conditioner does

 

Airflow is restricted.

 

• Make sure there are no curtains, blinds or furniture 

not cool as it should

 

 

  blocking the front of the air conditioner.

 

The temp control may

 

• On models with touch pads: In the

 Cool 

mode, press the 

 

not be set correctly.

 

 

Decrease

 

ź

 pad.

 

 

• On models with control knobs, turn the temperature 

 

 

  knob to a higher number.

 

The air filter is dirty.

 

• Clean the filter at least every 30 days. 

 

 

  See the Care and Cleaning section.

 

The room may have been hot.

 

• When the air conditioner is first turned on, you need  

 

 

  to allow time for the room to cool down.

 

Cold air is escaping.

 

• Check for open furnace registers and cold air returns.

 

Cooling coils have iced up.

 • 

See 

“Air conditioner freezing up”

 below.

Air conditioner

 

Ice blocks the air flow

 

• On models with control knobs, set the mode control at  

 

freezing up

 

and stops the air conditioner

 

 

High Fan

 or 

High Cool 

with the

 Temp 

at 

or 

2

.

 

from cooling the room.

 

• On models with touch pads, set the controls at 

High Fan

    

  

 

or 

High Cool 

and set the thermostat to a higher    

 

  

 

temperature.

The remote control

   

The batteries are inserted

 

• Check the position of the batteries. They should be  

is not working

 

incorrectly.

 

  inserted in the opposite (+) and (–) direction.

 

The batteries may be dead.

 

• Replace the batteries.

Water drips outside

 

Hot, humid weather. 

 

• This is normal.

Water drips indoors

 

The air conditioner is not

 

• For proper water disposal, make sure the air conditioner 

 

tilted to the outside.

 

  slants slightly from the case front to the rear.

Water collects in 

 

Moisture removed from air

  

• This is normal for a short period in areas with little 

base pan

 

and drains into base pan.

 

  humidity; normal for a longer period in very humid areas.

11

Summary of Contents for AEZ10AVL1

Page 1: ...k Cover Warranty 14 49 7748 10 15 GE AEW10 AEZ10 AEW12 AEZ12 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Serial _______________...

Page 2: ...safety do not store or use combustible materials gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance All air conditioners contain refrigerants which under fede...

Page 3: ...ectrician to make sure the outlet is properly grounded Where a 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 prong...

Page 4: ...onditioner is off it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings HOD 2 When the air conditioner is on it can be set to automatically turn off in 1 to 24...

Page 5: ...y set to the speed needed to provide optimum comfort settings with the set temperature If the room needs more cooling the fan speed will automatically increase If the room needs less cooling the fan s...

Page 6: ...iding it back into position NOTES Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long...

Page 7: ...mizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet So...

Page 8: ...ation Instructions Right accordion panel Foam top window gasket Left accordion panel Screw 6 Window sash seal Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Frame locking...

Page 9: ...ls if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord...

Page 10: ...ly constructed windows attach the window locking bracket to the window side jamb with one screw B C Wood Vinyl 3 Screws C 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the...

Page 11: ...sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may On models with touch pads In the Cool mode press the not be set corr...

Page 12: ...12 Notes...

Page 13: ...Notes GEAppliances com...

Page 14: ...KY 40225 Properly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sale...

Page 15: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...

Reviews: