background image

Please read this operation manual before using the air conditioner.

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09HEK03

HSU-09LEK03

HSU-12HEK03

HSU-12LEK03

0010518786

HSU-09LEK13
HSU-12LEK13

HSU-07LEK03

HSU-07HEK03

Summary of Contents for 10518786

Page 1: ...d this operation manual before using the air conditioner SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU 09HEK03 HSU 09LEK03 HSU 12HEK03 HSU 12LEK03 0010518786 HSU 09LEK13 HSU 12LEK13 HSU 07LEK03 HSU 07HEK03 ...

Page 2: ... disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s Guide contains very impor tant observations relating to the assembly operation and maintenance of the air conditioner The manufacturer does not accept respon sibility for any damages that may arise du...

Page 3: ...anufacturer or its service agent or a similar qualified person 4 The wiring method should be in line with the local wiring standard 5 After installation the power plug should be easily reached 6 The waste battery should be disposed properly 7 The appliance is not intended for use by young children or infirm persons without supervision 8 Young children should be supervised to ensure that they do no...

Page 4: ...se Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a inadequate place may cause accidents Do not install in the following place Connect the earth cable earthing Do not install in the place where there is any possibility of inflammable gas leakage around t...

Page 5: ...cially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION 4 PROHIBITION PROHIBITION PROHIBITIO...

Page 6: ...e Power plug Outlet Anion generator inside adjust left and right air flow Vertical blade Power indicator Timer mode indicator Operation mode indicator Lights up when unit starts Lights up whenTimer operation is selected lights up when the compressor is on Remote signal receiver A beeping sound is generated when a signal from remote controller isreceived 4 5 Ambient temp display When receiving the ...

Page 7: ... Used to select sleep mode 17 LOCK Used to lock buttons and LCD display 18 TEMP SETTING Used to select your desired temp 19 SET Used to confirm timer and clock settings 20 TIMER Used to select TIMER ON TIMER OFF TIMER ON OFF 21 CLOCK Used to set correct time 22 RESET normal condition Used to reset the controller back to LO MED HI AUTO Clock set When unit is started for the first time and after rep...

Page 8: ...K Used to lock buttons and LCD display 18 TEMP SETTING Used to select your desired temp 19 SET Used to confirm timer and clock settings 20 TIMER Used to select TIMER ON TIMER OFF TIMER ON OFF 21 CLOCK Used to set correct time 22 RESET normal condition Used to reset the controller back to LO MED HI AUTO Clock set When unit is started for the first time and after replacing batteries in remote contro...

Page 9: ...t as illustrated Put on the cover again Confirmation indicator In disorderation reload the batteries or load the new batteries after 6mins Note Use two new same typed batteries when loading If the remote controller can t run normally or doesn t work at all use a sharp pointed item to press the reset key Hint Remove the batteries in case unit won t be in usage for a long period If there are any dis...

Page 10: ...automatically adjusts the fan speed according to room temperature 1 3 Select temp setting Press TEMP button Every time the button is pressed temp setting increases 1 o C Every time the button is pressed temp setting decreases 1 o C Unit will start running to reach the temp setting on LCD In FAN operation mode the unit will not operate in COOL mode but only in FAN mode AUTO is not available in FAN ...

Page 11: ...on on remote controller display as follows according to different operation modes Pos 1 Pos 2 Pos 3 Pos 4 The horizontal flap will swing according to the above positions Cautions Hints As cold air flows downward in COOL mode adjusting air flow horizontally will be much more helpful for a better air circulation Do not try to adjust the flap by hand When adjusting the flap by hand turn off the unit ...

Page 12: ...ator on indoor unit lights up 4 Confirming your setting After setting correct time press SET button to confirm ON or OFF stops flashing Time displayed Unit starts or stops at x hour x min TIMER ON or TIMER OFF To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears Hints After replacing batteries or a power failure happens Time setting should be reset Remote controll...

Page 13: ...TIMER ON After time setting press TIMER button to confirm ON stops blinking While OFF starts blinking Time displayed Unit starts at x hour x min 5 Time setting for TIMER OFF Follow the same procedures in Time setting for TIMER ON 6 Time confirming for TIMER OFF After time setting press SET button to confirm OFF stops flashing Time displayed Unit stops at X hour X min Just press TIMER button severa...

Page 14: ...and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room Brief introduction to health anion function 3 To Cancel HEALTH Model is displayed on the remote HEALTH ON OFF FAN MODE SWING TIMER CLOCK SET SLEEP LOCK RESET Press HEALTH button controller When indoor fan motor is running it has healthy process function It s available under any mode 13 NOTE I...

Page 15: ...ing sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function When TIMER function is set the quiet sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on if the two modes are set up at the same time either of their operati...

Page 16: ...e system back to the normal operation mode Press the emergency operation switch once more or manipulate through the ON OFF button of remote controller after you heard the Pi sound the eme rgency or test operation will be terminated It is impossible to change the settings of temp and fan speed It is also not possible to operate in timer or dry mode Test operation switch is the same as emergency swi...

Page 17: ...ation If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Proper temperature During cooling operation prevent the penetration of direct sunlight with curtain or blind 16 OFF ...

Page 18: ...letely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the controller with a dry cloth Do not use glass cleaner or chemical cloth Gasoline benzine thinner or cleanser may damage the coating of the unit Hot water over 40 O C 104 O F may cause discoloring or deformat...

Page 19: ... This noise is generated by the casing expanding or shrinking because of temperature changes Should there be a big noise from air flow in unit operation air filter may be too dirty This is because the system circulates smells from the interior air such as the smell of furniture paint cigarettes During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of indoor a...

Reviews: