Operation Procedure

Operation Pr

ocedur

e

9

OPERATION FOR MECHANICAL MODEL

1. Main Control Knob

Set to Low Cool,

 High

 Cool or 

Turbo

 Cool as desired (FAN setting operates the fan only.)

CAUTION: If the main control knob is turned off o

r

 changed to a fan setting from a cooling operation

setting. WAIT at teast 3 minutes before resetting to cooling operation.

2. Thermostat control Knob

Set the thermostat control knob to your desired setting (Usually 6-7 is recommended), If the room
temperature is not as desired after a reasonable period, turn the thermostat. When the thermostat
control kno

b

 is set to 10 moisture may freeze onto evaporator fins and the thermostat control knob

counter clockwise, This will quickly defrost the evaporator fins so that mormal cooling can be resumed.

HIGH

COOL

TURBO

COOL

3. Air Swing Switch

(Airflow direction adjustment Side-to Side)
To obtain a fix airflow direction, set the air swing switch to “ON” for the
vanes to swing from side to side until the desired flow direction is
reached, then switch it to “OFF”. For continuous side-to-side air
circulation, set the air swing switch to “ON”.

OPERATION OF CONTROL PANEL FOR ELECTRONIC MODEL

Note:
Open the surface panel and operate manually.

1

POWER BUTTON
Under OFF mode, press the ON/OFF
button to turn on the unit. and stops
when pressing this button again.

2

SWING BUTTON
Activate the automatic air swing
function.

3

FAN SPEED BUTTTON
Select the fan speed LOW, HIGH,
TURBO, AUTO in sequence.

Summary of Contents for AEV07KP

Page 1: ...GE Window Type Air Conditioner AEV07KP AEV09KP AEV12KP AEV18KP AEV24KP AEE07KP AEE09KP AEE12KP AEE18KP AEE24KP Use Care Manual GE Appliances...

Page 2: ......

Page 3: ...eration for Mechanical Model 9 Operation of Control Panel for Electronic Model 9 Operation of Remote Control for Electronic Model 10 Operation Tips 13 To get the full benefit from your new Window Type...

Page 4: ...sed in residence shop hotel office library and laboratory and so on Cooling in summer In hot summer Air conditioner can cool down the room air by transferring heat out Dehumidifying in rainy or humid...

Page 5: ...l vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not work Earth wire To ensure the reliable earthing please do not connect earth wire to the...

Page 6: ...tact the seller before use Avoid a place where is possible for in flammable gas to leak out Avoid other heat sources or direct sun light Avoid a place where is easy for children to touch Don t use the...

Page 7: ...he cabinet with sponge or foam Installation assistance Use iron support The installation hole should be strong enough to support the air conditioner If it cannot iron support has to be used outdoors I...

Page 8: ...dure whichmay however cause a small loss of performance 1 Slide out the chassis from the cabinet 2 Remove the rubber plug from the body base plate 3 Install the drain pan to the corner of the cabinet...

Page 9: ...sive circuit must be used But removable socket can t be used because poor contact of it can cause over heat or fire Don t pull the power cord strongly In fixed circuit there must be electricity leakag...

Page 10: ...Lever When the slider at the OPEN position the ventilation door opens to allow air smoke or odors to be expelled from the room When the slider at the CLOSE position the ventilation door is closed and...

Page 11: ...porator fins and the thermostat control knob counter clockwise This will quickly defrost the evaporator fins so that mormal cooling can be resumed HIGH COOL TURBO COOL 3 Air Swing Switch Airflow direc...

Page 12: ...out a beep if remote control turbo speed by remote controller NOTE Control panel is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other Press an...

Page 13: ...r button on the unit or the Delay button on the remote control Use the Increase Decrease buttons on the unit or the Increase Decrease button on the remote control to set a new time if desired During p...

Page 14: ...or Normal Cooling Select the Cool mode and High or Turbo fan with a middle set temperature For Maximum Cooling Select the Cool mode and Turbo fan with a lower set temperature For Quieter Nighttime Coo...

Page 15: ...uniform temperature in the room Air can t be discharged to the direction of air in Make sure that the doors and windows are tightly closed Avoid opening doors and windows as much as possible to keep...

Page 16: ...T h i s c a u s e s l o w e r e d performance and irregular operation Do not insert sticks or other objects into these vents as it is dangerous to touch the electric components and the fan Select the...

Page 17: ...et If the cabinet is very dirty dip cloth into warm water below 40 C dry the cloth and then rub off the dirt Vacuum cleaner Air lock could result in bad efficiency 2 Vacuum the filter on the dusty sid...

Page 18: ...ng from air conditioner Air conditioner dose not operate for about 3minutes when restart Is air inlet or outlet locking Is there any other heat cool source in room Are air filters dirty very much Is i...

Page 19: ...ything else please contact the service center of GE Indoor Side DB WB Outdoor Side DB WB Maximum Cooling 32 23 43 26 Minimum Cooling 21 15 Maximum Heating 27 24 18 Minimum Heating 20 5 6 Working tempe...

Page 20: ...66129910152...

Reviews: