11
Troubleshooting Tips.
GEAppliances.com
Normal Operating Sounds
<RXPD\KHDUDSLQJLQJQRLVHFDXVHGE\ZDWHUEHLQJ
picked up and thrown against the condenser on rainy
days or when the humidity
is high. This design feature helps remove moisture and
improve efficiency.
<RXPD\KHDUWKHWKHUPRVWDWFOLFNZKHQWKH
compressor cycles on and off.
Water will collect in the base pan during
high humidity or on rainy days. The water
may overflow and drip from the outdoor side
of the unit.
The fan may run even when the compressor
does not.
Problem
Possible Causes
What To Do
Air conditioner
The air conditioner
Make sure the air conditioner plug is pushed
does not start
is unplugged.
completely into the outlet.
The fuse is blown/circuit
Check the house fuse/circuit breaker box and replace
breaker is tripped.
the fuse or reset the breaker.
Power failure.
The unit will automatically restart in the settings last
used after the power is restored.
There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling for 3 minutes after it is turned
back
on.
The current interrupter
Press the
RESET
button located on the power cord plug.
device is tripped.
If the
RESET
button will not stay engaged, discontinue
use of the air conditioner and contact a qualified
service
technician.
Air conditioner does
Airflow is restricted.
Make sure there are no curtains, blinds or furniture
not cool as it should
blocking the front of the air conditioner.
The temp control may
On models with touch pads: In the
Cool
mode, press the
not be set correctly.
Decrease
–
pad.
2QPRGHOVZLWKFRQWURONQREVWXUQWKHWHPSHUDWXUH
knob to a higher number.
The air filter is dirty.
Clean the filter at least every 30 days.
See
the
Care and Cleaning
section.
The room may have been hot.
When the air conditioner is first turned on, you need
to allow time for the room to cool down.
Cold air is escaping.
Check for open furnace registers and cold air returns.
Cooling coils have iced up.
See
“Air conditioner freezing up”
below.
Air conditioner
Ice blocks the air flow
On models with control knobs, set the mode control at
freezing up
and stops the air conditioner
High Fan
or
High Cool
with the
Temp
at
1
or
2
.
from cooling the room.
2QPRGHOVZLWKWRXFKSDGVVHWWKHFRQWUROVDW
High Fan
or
High Cool
and set the thermostat to a higher
temperature.
The remote control
The batteries are inserted
Check the position of the batteries. They should be
is not working
incorrectly.
inserted in the opposite (+) and (–) direction.
The batteries may be dead.
Replace the batteries.
Water drips outside
Hot, humid weather.
This is normal.
Water drips indoors
The air conditioner is not
For proper water disposal, make sure the air conditioner
tilted to the outside.
slants slightly from the case front to the rear.
Water collects in
Moisture removed from air
This is normal for a short period in areas with little
base pan
and drains into base pan.
humidity; normal for a longer period in very humid areas.