background image

4

About the controls on the air conditioner.

Features and appearance will vary.
Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Fan

Fan

     Delay  1–24hr

  Delay  timer 

Decrease

Mode select

Fan speed  

Decrease
Temperature  

set Increase 

and Decrease

  Delay 

timer  

Increase 
  Auto Fan  

on
Fan speed  

Increase
 Unit  power  

on/off

Air Conditioner Controls

Controls

Power Pad

 

Turns air conditioner on and off. When 

turned on, the display will show the room 

temperature.

Display

 

Shows the room temperature or time 

remaining on the Delay timer. Shows the

 Set 

temperature while setting the temperature in 

Cool 

or 

Energy Saver 

modes. The

 Set

 light will 

turn on while setting.

Temp Increase 

Ÿ

 

/Decrease 

ź

 

Pads

 

Use to set temperature when in

 Cool 

or 

Energy Saver

 mode. The 

Set

 light will turn on 

while setting.

Delay Timer Increase

Ÿ

 (+) /Decrease 

ź

(–) Pads

 

Each touch of the 

Increase

 

Ÿ

 / 

Decrease 

ź

 

pads on the unit or the

 Increase 

+

 

Decrease 

 pads on the remote control will set the delay 

time when using the 

Delay 1–24hr

 

timer. The 

Set

 light will turn on while setting.

Fan Speed Pads

 

Use to set the fan speed to

 Low, Med, High 

 

or 

Auto

 on the unit. 

NOTE:

 On the remote 

control, use the fan speed

 Increase 

Decrease 

 

pads to set the fan speeds to 

Low, 

Med 

or 

High

. Use the 

Auto

 pad to turn 

Auto

  

fan on.

 

Mode Pad

Use to set the air conditioner to 

Cool, Energy 

Saver

 or 

Fan Only

 mode.

Delay Pads/Delay 1-24hr Pad

'HOD\21³

When the air conditioner is off, it can 

be set to automatically come on in 1 to 24 hours 

at its previous mode and fan settings. 

'HOD\2))³

When the air conditioner is on,  

it can be set to automatically turn off in 1 to  

24 hours. 

How to set:

Press the 

Delay 1–24hr

 pad on the unit or the 

Delay pad 

on the remote control.  Each touch 

of the 

Increase

 

Ÿ

 

Decrease

ź

pads on the 

unit or the 

Increase 

Decrease 

 

pads on 

the remote control will set the timer in 1-hour 

intervals. The 

Set

 light will turn on while setting.

To review the remaining time on the 

Delay 

1–24hr

 timer, press the 

Delay 1–24hr

 pad on 

the unit or the 

Delay pad 

on the remote control. 

Use the 

Increase

 

Ÿ

 / 

Decrease

 

ź

 pads on the 

unit or the 

Increase 

+

 

Decrease 

 

pads on the 

remote control to set a new time if desired.

To cancel the timer,

 press the 

Delay 1–24hr 

pad 

until the light on the

 Delay 1–24hr

 pad goes off.

Reset Filter

 

LED will turn on when fan has accumulated 250 

hours of run time as a reminder to clean filter. 

Press 

Reset Filter

 to turn off the LED and reset 

the accumulated run time.

Note:

 The default temperature reading on the display is degree Fahrenheit ( °F).  To change the display to 

degree Celcius (°C), press the Temp Increase 

Ÿ

 and Temp Decrease 

ź

 buttons together and hold for 3 

seconds.  Repeat the process to change back to degree Fahrenheit (°F)

NOTE: 

The display always shows the room temperature except 

when setting the Set temperature or the Delay timer.

Power

On/Off

Fan

Mode

Auto

Reset

Filter

High
Med
Low

Cool
Fan Only
Energy Saver

Delay

1-24 Hrs

Set

+

-

8

Light indicates the 

delay timer is set.

Light indicates the unit is in the 

temperature or delay time Set mode.

Remote Control

Summary of Contents for AEN08LS

Page 1: ...15 49 7729 11 13 GE AEN08 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Serial __________________________ Find these numbers on a...

Page 2: ...0A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R22 refrigerant on...

Page 3: ...injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Conditioner USE OF EXTENSION CORDS READ AND FOLL...

Page 4: ...onditioner is off it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings HOD 2 When the air conditioner is on it can be set to automatically turn off in 1 to 24...

Page 5: ...y set to the speed needed to provide optimum comfort settings with the set temperature If the room needs more cooling the fan speed will automatically increase If the room needs less cooling the fan s...

Page 6: ...iding it back into position NOTES Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long...

Page 7: ...equire 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloading house or...

Page 8: ...anel Window sash seal thin adhesive backed Foam top window gasket Window locking bracket 1 Left accordion panel Top mounting rail Installation Instructions PARTS INCLUDED appearance may vary Type C 5...

Page 9: ...window sill or if you have a window without a sill you must order accessory kit RAK87 to properly install this air conditioner Call 800 626 2002 or visit GEAppliances com The air conditioner can be i...

Page 10: ...width and stick the adhesive side to the bottom of the sash 7 Window sash seal INSIDE 4 ATTACH THE TOP MOUNTING RAIL SEAL STRIP Remove the backing from the top mounting rail seal strip and attach the...

Page 11: ...ordion panels to each window sash track Attach them on each side to the window sash and the window sill using 4 Type C screws 8 A B C D E 11 9 INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET Attach...

Page 12: ...10 D INSTALL THE AIR CONDITIONER IN THE CASE Slide the air conditioner into the case by the base pan Do not push on the controls styrofoam air discharge housing or the finned coils Make sure the air c...

Page 13: ...ir conditioner and contact a qualified service technician Air conditioner does Airflow is restricted Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the...

Page 14: ...14 Notes...

Page 15: ...essible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by i...

Page 16: ...lable while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty exp...

Page 17: ...7729 11 13 GE AEN08 Acondicionador de aire GEAppliances com Habitaci n Escriba los n meros de modelo y serie aqu de Modelo_________________ de Serie___________________ Puede encontrar estos n meros en...

Page 18: ...de acondicionadores de aire R410A requieren quelos contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con estere frigerante NO use equipamiento certifica...

Page 19: ...aves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples tomacorrientes con este Acondicionador de Air...

Page 20: ...rol remoto Cada toque de las teclas Aumento Reducci n en la unidad o las teclas Aumento Reducci n en el control remoto definir el temporizador en intervalos de 1 hora La luz de Ajuste se encender dura...

Page 21: ...ocidad de ventilador autom tica No use en las condiciones externas debajo el punto de congelaci n Este acondicionador de aire no es dise ado para usar en temperaturas externas debajo el punto de conge...

Page 22: ...ab n Enju guelo y permita que se seque antes de colocarlo otra vez en su lugar No lave el filtro en un lavavajillas PRECAUCI N NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad...

Page 23: ...mpleta y cuidadosamente IMPORTANTE Guarde estas instrucciones para uso del inspector local IMPORTANTE Observe todos los c digos y rdenes de ley Nota al instalador Aseg rese de dejar estas instruccione...

Page 24: ...oqueo de ventana 1 Panel de acorde n izquierdo Riel de montaje superior PARTES INCLUIDAS aspecto pueden variar Instrucciones para la instalaci n Tipo C 5 Tipo D 2 HERRAMIENTAS QUE NECESITAR Un destorn...

Page 25: ...y lev ntela NOTA No hale el borde inferior hacia usted m s de 3 o podr a da ar las leng etas de la rejilla Cuando se retire la parrilla del frente el panel de control a n se encontrar adjunto por un a...

Page 26: ...ntaje superior Tornillos tipo A Riel de montaje superior Riel de montaje inferior Panel de acorde n POSTERIOR REMUEVA EL ACONDICIONADOR DE AIRE DE LA CAJA CONT FRENTE No tire o levante en esta iUHD po...

Page 27: ...da paso del marco de la ventana nalos a cada lado del marco de la ventana y el umbral de la ventana usando 4 tornillos tipo C 8 A B C D E 11 9 INSTALE UN SOPORTE DE CIERRE Y LA JUNTA DE ESPUMA SUPERIO...

Page 28: ...NDICIONADOR DE AIRE EN LA CAJA Deslice el acondicionador de aire hacia el interior de la caja mediante la rejilla base No empuje por los controles la carcasa de descarga de aire de espuma de poliestir...

Page 29: ...cnico calificado El acondicionador de aire El flujo de aire est restringido Cerci rese de que no existe ninguna cortina persiana o no enfr a como deber a mueble bloqueando el frente del acondicionador...

Page 30: ...14 Notas...

Page 31: ...que lleve el producto a una centro de servicio de GE autorizado para realizar la reparaci n En Alaska la garant a excluye el costo de env o o las visitas de servicio a su casa Algunos estados no perm...

Page 32: ...s manden las piezas o accesorios directamente a sus hogares aceptamos las tarjetas VISA MasterCard y Discover Haga su pedido en l nea hoy 24 horas cada d a o llamar por tel fono al 800 626 2002 durant...