12
Set Temperature Compensation:
:LWKWKHGLVSOD\RႇSUHVVDQGKROGWKH)$1EXWWRQIRUVHFRQGV
The display will then show 0 (default) or current compensation set-
ting. Use TEMP+/- buttons to adjust the compensation. Compensa-
tion can be set in 1° increments
+/- 8°F (0.5°C increments up to +/-4°C).
• Temperature compensation changes the ambient temperature
reading. If the system is sensing the ambient temperature at 72°F
and the compensation is set to -2° then the system will use 70°F in
its operation to heat or cool.
Forced Defrost:
• Set to Heating mode, high fan, and 86°F (30°C), or highest
temperature if ECO is on. Press TEMP+ 6 times within 5 seconds.
7KUHHWRQHVZLOOFRQ¿UPWKDWWKHXQLWLVLQIRUFHGGHIURVWPRGH
Forced Cooling:
• Set mode to Cool. Tap ON/OFF. Tap any button, except ON/OFF,
to light the display. Press and hold ON/OFF for 5 seconds. LL will
GLVSOD\DQGWKHFRQWUROZLOOEHHSWZLFH7RH[LWWXUQRႇFRQWURODQG
turn it on again.
Forced Heating:
• Set mode to Heat. Tap ON/OFF. Tap any button, except ON/OFF,
to light the display. Press and hold ON/OFF for 5 seconds. HH will
GLVSOD\DQGWKHFRQWUROZLOOEHHSWZLFH7RH[LWWXUQRႇFRQWURODQG
turn it on again.
Temperature Compensation