Product Code Description Code

Voltage

IP Rating

Maximum Run Length

62199

(LWW1-HO12-012-827)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

For 120 VAC: 70 Fixtures 

(~73.5 feet/22.41m)  

For 240 VAC: 140 Fixtures 

(~147 feet/44.82m)

For 277 VAC: 165 Fixtures 

(~173.3 feet/52.84m)

62202

(LWW1-HO12-030-827)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62191

(LWW1-HO12-110-827)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

65444

(LWW1-HO12-012-830)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

65445

(LWW1-HO12-030-830)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62192

(LWW1-HO12-110-830)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62200

(LWW1-HO12-012-840)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62203

(LWW1-HO12-030-840)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62195

(LWW1-HO12-110-840)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62204

(LWW1-MO12-012-827)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

For 120 VAC: 140 Fixtures 

(~147 feet/44.82m)

For 240 VAC: 290 Fixtures 

(~304.5 feet/92.84m)

For 277 VAC: 300 Fixtures 

(~315 feet/96.04m)

62206

(LWW1-MO12-030-827)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62196

(LWW1-MO12-110-827)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

65446

(LWW1-MO12-012-830)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

65447

(LWW1-MO12-030-830)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

65448

(LWW1-MO12-110-830)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62205

(LWW1-MO12-012-840)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

62207

(LWW1-MO12-030-840)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

65449

(LWW1-MO12-110-840)

120 VAC-277 VAC, 50-60Hz

IP51: Dry or Damp Location

Specifications

Troubleshooting

ARCH053-100213

Symptom

Solution

All LED fixtures are not 

illuminated

• Check leader cable connection and/or check circuit breaker.

• Check plug connectors on the LED fixtures for improper connections or short circuits.

• Ensure leader cable is securely connected to the female plug connector on the first LED fixture.

Some LED fixtures are 

not illuminated

• Check plug connectors on the LED fixtures for improper connections or short circuits.

• Ensure any jumper cables are securely connected between the male/female plug connectors of the 

LED fixtures.

Shadows within 

application

• Re-position LED fixtures along mounting surface ensuring architectural elements are not directly in 

front of any LEDs.

• Adjust layout of LED fixtures to ensure uniformity of illumination.

• Adjust leader cable and/or jumper cable orientation to ensure cables do not cover any LEDs.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harm-

ful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This 

Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme á la NMB-003 du Canada.

Note: 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial 

environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to 

cause harmful interference in which case the user will be required to correct the interference at his own expense.

(1- 888 - 69 - 43-533)

GE Lighting  •  1-888-MY-GE-LED

GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company.

© 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

•  www.gelighting.com

Summary of Contents for 62191

Page 1: ...mpletely and carefully Save These Instructions This product is intended solely for the use of non residential architecture lighting and is not intended for use in any other application Prepare Electrical Wiring Electrical Requirements Do not use in wet locations The grounding and bonding of the LED system shall be done in accordance with National Electric Code NEC Article 600 Follow all National E...

Page 2: ...ds Mounting surface Mounting track can be installed at 0 and 30 degree angles Fixture has three positions at 10 degree increments 0 10 10 20 30 40 50 20 30 40 50 1 2 3 4 5 6 6 GE LED Wall Washer Fixtures Leader Cable with End Cap 62208 62211 Mounting track with bracket 65467 UL approved 18 14 AWG 0 82 2 08 mm2 wire connectors or In Line Splice Connector 75545 10 M5 self tapping flathead screws Opt...

Page 3: ...them together Connect the leader cable to the power source and dimmer OPTIONAL If dimming is not used cap the purple and gray wires with UL approved wire connectors Do not connect the wires together Continue placing fixtures being sure to join plugs male to female Attach jumper cables as needed to work around any obstacles corners or separations 1 2 Snap the first LED fixture into the mounting tra...

Page 4: ...ts Ensure leader cable is securely connected to the female plug connector on the first LED fixture Some LED fixtures are not illuminated Check plug connectors on the LED fixtures for improper connections or short circuits Ensure any jumper cables are securely connected between the male female plug connectors of the LED fixtures Shadows within application Re position LED fixtures along mounting sur...

Reviews: