background image

Leader cable to LED fixture

Gray (-0-10V)

Blue (+0-10V)

Black (+)

White (-)

Green (ground)

120-277V 

AC Line

Dimmer

Leader cable to LED fixture

Gray (-0-10V)

Black (+0-10V)

Brown (+)

Blue (-)

Green/yellow 
(ground)

240 VAC 

Line

Dimmer

Snap in LED fixture

Install mounting track inside the 

wall cavity using a minimum 

of two #10 (M5) self-tapping 

flathead screws per section. If 

required, cut mounting track to 

desired length.

Assemble the LED fixture and 

the bracket by pressing them 

together.

Connect the leader cable to the power source and dimmer.

OPTIONAL:

 If dimming is not used, cap the purple and gray wires with UL approved wire connectors. Do not connect the 

wires together.

Continue placing fixtures, being 

sure to join plugs male to female. 

Attach jumper cables as needed 

to work around any obstacles, 

corners or separations. 

1

2

Snap the first LED fixture into the 

mounting track.

4

Connect the leader cable to the 

male plug on the first LED fixture.

3

5

6

Leader cable

Installation

Electrical Connections

Orient plugs male to female

Place end cap from leader cable 

on the electrical plug of the last 

fixture in the run.

Summary of Contents for 62191

Page 1: ...mpletely and carefully Save These Instructions This product is intended solely for the use of non residential architecture lighting and is not intended for use in any other application Prepare Electrical Wiring Electrical Requirements Do not use in wet locations The grounding and bonding of the LED system shall be done in accordance with National Electric Code NEC Article 600 Follow all National E...

Page 2: ...ds Mounting surface Mounting track can be installed at 0 and 30 degree angles Fixture has three positions at 10 degree increments 0 10 10 20 30 40 50 20 30 40 50 1 2 3 4 5 6 6 GE LED Wall Washer Fixtures Leader Cable with End Cap 62208 62211 Mounting track with bracket 65467 UL approved 18 14 AWG 0 82 2 08 mm2 wire connectors or In Line Splice Connector 75545 10 M5 self tapping flathead screws Opt...

Page 3: ...them together Connect the leader cable to the power source and dimmer OPTIONAL If dimming is not used cap the purple and gray wires with UL approved wire connectors Do not connect the wires together Continue placing fixtures being sure to join plugs male to female Attach jumper cables as needed to work around any obstacles corners or separations 1 2 Snap the first LED fixture into the mounting tra...

Page 4: ...ts Ensure leader cable is securely connected to the female plug connector on the first LED fixture Some LED fixtures are not illuminated Check plug connectors on the LED fixtures for improper connections or short circuits Ensure any jumper cables are securely connected between the male female plug connectors of the LED fixtures Shadows within application Re position LED fixtures along mounting sur...

Reviews: