Summary of Contents for 49-90383

Page 1: ...ly crushed and traplint Theseconditions will obstruct drger airflow and increase the risk of fire Do not install or store this appliance in ang location where it could be exposed to water andlor weather Save these instructions Installers Be sure to leave these instructions with the customer This appliance must be properlg grounded and installed as described in these instructions IMPORTANT Exhousti...

Page 2: ...shipping clips that secure the drain hose to the left side of the washer bocksheet DO NOT REMOVETHE PLASTICCLAMPSon the right side of the washer These clamps form o standpipe to prevent water siphoning Dryer support pads UNPACKING SPACEMAKER CONT NOTE The tub blocking pod shipping bolt and plastic spacer should be retained for use if the appliance is transported at o later dote I 8 1 Form the end ...

Page 3: ...etermine which water faucet is the HOT water faucet carefully connect the bottom inlet hose to the HOTwater faucet tighten by hand and then tighten another 2 3 turn with pliers Carefully connect the top inlet hose to the COLDwater faucet tighten by hand and then tighten another 2 3 turn with pliers _A CAUTION DO NOT CROSS THREAD OR OVERTIGHTENTHESECONNECTIONS CONNECTING TO PLUMBING FACILITIES CONT...

Page 4: ...n an area where the temperature will fall below freezing If appliance is stored or transported in freezing temperatures be sure all water from the fill and drain sgstems has been removed DRAIN REQUIREMENTS DRAINRATE The drain or standpipe must be capable of accepting a discharge at the rate of 16 gallons per minute DRAINHEIGHT The drain height must be 33 minimum and 96 maximum STANDPIPE DIAMETER T...

Page 5: ...urce circuit breaker fuse box r_ Plug power cord into electrical outlet _ Return to Step 15 on page 3 NOTE THISAPPLIANCEISNOTAPPROVEDFOR120 VOLT OPERATION 3 WIRE CONNECTION UNGROUNDED NEUTRAL This appliance is manufactured with the neutral connected to the frame If local codes do not ermit neutral grounding proceed as follows Remove the terminol block occess cover Disconnect the green ground wire ...

Page 6: ...y 4 rigid metal ducting for the home exhaust duct Use only 4 rigid metal or UL listed flexible metal semi rigid or foil type duct to connect the dryer to the home exhaust duct It must be installed in accordance with the instructions found in Connecting the Dryer to House Vent on page 7 of this manual Do not terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an enclose...

Page 7: ...ONT UL Listed Flexible Metal Foil Type Transition Duct In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLYin installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the t...

Page 8: ...mum clearances shown above CONSIDERATION MUST BE GIVEN TO PROVIDE ADEQUATE CLEARANCES FOR INSTALLATION AND SERVICE ACAUTION DO NOT INSTALL THIS APPLIANCE IN A CLOSET WITH A SOLID DOOR DOOR VENTILATION OPENING A minimum of 120 square inches of opening equally divided at top and bottom is required Air openings are required to be unobstructed when a door is installed A Iouvered door with equivalent a...