There is a 30 second delay.
4. When you finish testing the system, call the central
station to verify that the alarms were received.
Specifications
Power
9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid.
The battery will last 24 hours with no AC and
specified standby load of 250 mA. Maximum
battery charging current is 45 mA. With loss of
AC, panel will continue to operate normally to a
minimum of 5.1 VDC.
Radio frequency
319.5 MHz
Storage temperature
-29 to 140ºF (-34 to 60ºC)
Operating
temperature
32 to 120ºF (0 to 49ºC)
Maximum humidity
85% relative humidity, noncondensing
Auxiliary power
Unregulated 5.3 to 12.3 VDC, with a maximum of
250 mA
Regulatory information
UL listed installations
Some installation may require configurations dictated by
city/state codes, insurance, or Underwriter’s Laboratories
(UL). This section describes the various component and
configuration listings.
Basic system:
• Control panel: Backup battery 6 V 1.2 Ah (34-025)
(Portalac model # PE6V1.2)
• Standard class 2, 9 VAC, 3.34 A power transformer (GE
Security part 22-153). Alternate transformer for US
installations: MG Electronics model MGT925, 9 VAC, 25
VA, (GE Security part 22-155)
• Hardwired siren (13-374)
Household burglary alarm system unit (UL 1023), basic
system plus the following:
• Hardwired magnetic contact (13-068 or 13-071) or
wireless learn mode door/window sensor (60-670)
• Panel piezo beeps set to on
• Entry delay set to 45 seconds or less
• Exit delay set to 60 seconds or less
• RF time-out set to 24 hours
• Control panel alarms turned on
• Auto arm set to on
• Siren timeout set to 5 minutes or more
• Trouble beeps set to on
• RF jam detect set to on
• Hardwired siren supervision set to on
• Exit extension set to off
• Quick exit set to off
Household fire warning system (UL 985), basic system plus
the following:
• Wireless smoke sensor 60-848-02-95, TX-6010-01-1
learned into sensor group 26.
• Panel piezo beeps turned on
• Control panel alarms set to on
• Siren timeout set to 4 minutes or more
• Trouble beeps set to on
• RF jam detect set to on
• Hardwired siren supervision set to on
• Smoke supervision set to on
UL 1023 and 985 24-hour backup:
• For 24-hour backup, the total current draw for all
connected devices is limited to 240 mA (during normal
standby conditions) using a 1.2 AH battery.
UL 1635 digital alarm communicator system (same as UL
1023 and 985) plus the following settings are in addition to
UL 1023 and 985 and are required only if the system is set
up for central station reporting:
• Phone mod 1 set to 0 or 1
• Automatic phone test set to 001
• RF timeout set to 4 hours
• AC power failure report set to on
• CPU low battery report set to on
• Fail to communicate set to on
• Entry delay plus the dialer delay must not exceed 60
seconds
SIA system requirements
SIA system requirements are the same as those described
for a UL-listed basic system, plus if multiple annunciations
are required, use hardwired siren 13-046.
Note:
For UL 1635 installations, entry delay plus dialer abort
delay must not exceed 60 seconds.
Table 8 below describes programming requirements to
meet ANSI-SIA CP-01.
Table 8: SIA setting requirements
Function Default
setting
Required
setting
Entry delay
30 seconds
30 to 240 seconds
Exit delay
60 seconds
45 to 240 seconds
Dialer delay
30 seconds
15 to 45 seconds
Auto arm
On
On
Unvacated premises
On
On
Simon XT V2 Installation Guide