The display shows
Learn Sensor
.
4. Press
OK.
The display shows
Trip Sensor ##
, with the
number signs flashing.
If you wish to use a sensor number other than the next
one available, use the number keys to enter a two-digit
sensor number immediately.
5. Press the sensor program button or release the sensor
tamper switch.
The display shows
SN ## Grp10 <Front Door>
,
with Grp 10 flashing.
6. Use the number or scroll buttons if you want to enter a
new group number; press OK to accept the group
number displayed.
The sensor text flashes.
7. Scroll through the text list. Press OK to accept the first
text segment.
8. You may enter more text or press OK again to finish
adding the sensor.
The display shows
Trip Sensor ##
(with the next
available sensor number).
9. Press Status repeatedly to exit.
Sensor testing
Test the sensors after all programming is completed and
whenever a sensor-related problem occurs.
Note:
While the sensor test is a valuable installation and
service tool, it only tests sensor operation for the current
conditions. You should perform a sensor test after any
change in environment, equipment, or programming.
Notify the central station you will be performing a test prior
to starting the test.
To test the sensors:
1. Place all sensors in their secured (non alarm) state.
2. Scroll to Sensor Test options under the System Tests
menu, and then press OK.
The panel will prompt you to trip each sensor one at a
time. You may follow the panel prompting or test the
sensors in any order. See Table 7 below for specific
instructions on how to trip each sensor type.
Interior sirens sound transmission beeps, and the
display identifies the tripped sensor and the number of
RF packets received. The system will continue to
prompt for sensors that have not yet been tested.
When all sensors have been tested, the display shows
SN Test Complete Press Status
.
3. Press
Status.
The display shows
Sensor Test OK
.
If you press Status and the panel has not heard from all
sensors, the display shows
SN Test Fail or
Aborted
.
Table 7: Sensor tripping instructions
Sensor Do
this
Door/window
Open the secured door or window.
Freeze
Remove the sensor cover. Apply ice in a plastic bag to
the sensor (for 10 to 15 minutes). Do not allow the
sensor to get wet.
Water
Press a wet rag or wet finger over both of the round,
gold-plated terminals on the underside of the sensor.
Carbon
monoxide alarm
Unplug the CO alarm. Plug it back in, wait five seconds,
then press the Test/Reset button until the unit beeps
eight times.
Glassbreak
Test with an appropriate glass break sensor tester.
Motion sensor
Avoid the motion sensor field of view for 5 minutes,
and then enter its view.
Rate-of-rise heat
detector
Rub your hand together until warm, and then place
one hand on the detector for 30 seconds.
Shock
Tap the glass twice, away from the sensor. Wait at
least 10 seconds before testing again.
Smoke
Press and hold the test button until the system sounds
transmission beeps.
Personal help
button
Press and hold the appropriate help button until the
light blinks and the panel sounds for at least seven
beeps.
Key fob
Press and hold the Lock and Unlock buttons
simultaneously for 3 seconds.
Remote
touchpad
Press and hold the two Emergency buttons
simultaneously for 3 seconds.
Central station communication
After performing sensor tests, check that the system is
reporting alarms successfully to the central station.
To test communication with the central station:
1. Call the central station and tell the operator that you
will be testing the system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least
one sensor of each type (fire, intrusion, etc.) to verify
that the appropriate alarms are working correctly.
6