GE Security Simon XT V2 Installation Manual Download Page 6

The display shows 

Learn Sensor

4. Press 

OK. 

The display shows 

Trip Sensor ##

, with the 

number signs flashing. 

If you wish to use a sensor number other than the next 
one available, use the number keys to enter a two-digit 
sensor number immediately. 

5.  Press the sensor program button or release the sensor 

tamper switch. 

The display shows 

SN ## Grp10 <Front Door>

with Grp 10 flashing.  

6.  Use the number or scroll buttons if you want to enter a 

new group number; press OK to accept the group 
number displayed. 

The sensor text flashes. 

7.  Scroll through the text list. Press OK to accept the first 

text segment.  

8.  You may enter more text or press OK again to finish 

adding the sensor. 

The display shows

 Trip Sensor ##

 (with the next 

available sensor number). 

9.  Press Status repeatedly to exit. 

Sensor testing 

Test the sensors after all programming is completed and 
whenever a sensor-related problem occurs. 

Note: 

While the sensor test is a valuable installation and 

service tool, it only tests sensor operation for the current 
conditions. You should perform a sensor test after any 
change in environment, equipment, or programming. 

Notify the central station you will be performing a test prior 
to starting the test.  

To test the sensors: 

1.  Place all sensors in their secured (non alarm) state. 

2.  Scroll to Sensor Test options under the System Tests 

menu, and then press OK. 

The panel will prompt you to trip each sensor one at a 
time. You may follow the panel prompting or test the 
sensors in any order. See Table 7 below for specific 
instructions on how to trip each sensor type. 

Interior sirens sound transmission beeps, and the 
display identifies the tripped sensor and the number of 
RF packets received. The system will continue to 

prompt for sensors that have not yet been tested. 
When all sensors have been tested, the display shows 

SN Test Complete Press Status

3. Press 

Status. 

The display shows 

Sensor Test OK

If you press Status and the panel has not heard from all 
sensors, the display shows 

SN Test Fail or 

Aborted

Table 7: Sensor tripping instructions 

Sensor Do 

this 

Door/window 

Open the secured door or window. 

Freeze 

Remove the sensor cover. Apply ice in a plastic bag to 
the sensor (for 10 to 15 minutes). Do not allow the 
sensor to get wet. 

Water 

Press a wet rag or wet finger over both of the round, 
gold-plated terminals on the underside of the sensor. 

Carbon 
monoxide alarm 

Unplug the CO alarm. Plug it back in, wait five seconds, 
then press the Test/Reset button until the unit beeps 
eight times. 

Glassbreak 

Test with an appropriate glass break sensor tester. 

Motion sensor 

Avoid the motion sensor field of view for 5 minutes, 
and then enter its view. 

Rate-of-rise heat 
detector 

Rub your hand together until warm, and then place 
one hand on the detector for 30 seconds. 

Shock 

Tap the glass twice, away from the sensor. Wait at 
least 10 seconds before testing again. 

Smoke 

Press and hold the test button until the system sounds 
transmission beeps. 

Personal help 
button 

Press and hold the appropriate help button until the 
light blinks and the panel sounds for at least seven 
beeps. 

Key fob 

Press and hold the Lock and Unlock buttons 
simultaneously for 3 seconds. 

Remote  
touchpad 

Press and hold the two Emergency buttons 
simultaneously for 3 seconds. 

 

Central station communication 

After performing sensor tests, check that the system is 
reporting alarms successfully to the central station. 

To test communication with the central station: 

1.  Call the central station and tell the operator that you 

will be testing the system. 

2.  Arm the system. 

3.  Test each of the wireless panic buttons and trip at least 

one sensor of each type (fire, intrusion, etc.) to verify 
that the appropriate alarms are working correctly. 

Simon XT V2 Installation Guide 

Summary of Contents for Simon XT V2

Page 1: ... intrusion protection Table 1 below describes the recommended sensor groups Table 1 Recommended sensor groups Device Recommended sensor group Indoor motion sensor 17 a Outdoor motion sensor 25 chime only group b Entry exit door 10 Interior door 14 Window sensor 13 Smoke sensor 26 c Key fob 01 ELM key fob 01 Remote handheld touchpad 01 CO alarm 34 b Freeze sensor 29 b Water sensor 38 b Personal hel...

Page 2: ...nect hardwired reed switches normally closed loop only to HW1 I O if not being used for a hardwired siren an or HW2 in terminal 3 Connect only normally closed NC reed switches to HW1 I O and or HW2 in Other types of hardwired detectors should not be used The total resistance of the wired loop must not exceed 3 ohms This allows you to use up to 200 ft 61 m of two conductor 22 gauge stranded wire Co...

Page 3: ... end of the red battery lead to the red battery tab 2 Connect the lug end of the black battery lead to the black battery tab 3 Align the red battery terminal with the right end of the terminal strip The logo and specification information should be readable 4 Insert the front end of the battery under the forward battery compartment latch 5 Push forward and rotate the battery downward until it seats...

Page 4: ...vity if no access code has been entered yet After an access code has been entered to access a code protected area of the system menu the timeout is four minutes Menu navigation Each menu contains a list of options and or submenus Press the scroll buttons to navigate up and down the list of options and submenus in that menu Pressing OK after navigating to an option selects that option for editing a...

Page 5: ...panel memory The panel recognizes a sensor when you press a sensor program button press and release a tamper switch press a sensor test button or put a sensor into alarm Table 6 below describes the programming method for each device Note If you are installing a sensor on a gun case jewelry box or a similar case and the sensor is active in level one you must subdisarm to avoid putting the panel int...

Page 6: ...en all sensors have been tested the display shows SN Test Complete Press Status 3 Press Status The display shows Sensor Test OK If you press Status and the panel has not heard from all sensors the display shows SN Test Fail or Aborted Table 7 Sensor tripping instructions Sensor Do this Door window Open the secured door or window Freeze Remove the sensor cover Apply ice in a plastic bag to the sens...

Page 7: ... set to 5 minutes or more Trouble beeps set to on RF jam detect set to on Hardwired siren supervision set to on Exit extension set to off Quick exit set to off Household fire warning system UL 985 basic system plus the following Wireless smoke sensor 60 848 02 95 TX 6010 01 1 learned into sensor group 26 Panel piezo beeps turned on Control panel alarms set to on Siren timeout set to 4 minutes or m...

Page 8: ...allations Canadian standards CSA certified accessories Standard Class 2 9 VAC 3 34 A power transformer GE Security model 22 153 CN Residential burglary alarm system unit ORD C1023 1974 basic system as described for UL 1023 listed installations plus Hardwired magnetic contact 13 068 or 13 071 or wireless learn mode door window sensor 60 670 Siren timeout set to six minutes or more Residential fire ...

Reviews: