GE Security Simon XT V2 Installation Manual Download Page 1

GE

 

Security 

Simon XT V2 Installation Guide 

Content 

Contact information   1

 

Description   1

 

Installation   1

 

Connecting hardwired devices   2

 

Wiring phone lines   2

 

Wiring the power transformer   3

 

Programming   3

 

Sensor testing   6

 

Specifications   7

 

Regulatory information   7

 

 

Contact information 

For contact information see our Web site: 
www.gesecurity.com. 

Description 

 

© 2010 GE Security, Inc. 

P/N 466-2375 • REV A • ISS 24FEB10 

This is the Installation Guide for the Simon XT control panel 
(model 600-1054-95R-V2). 

The system can monitor up to 40 sensors including: 

• Door/Window 

sensor 

(60-670) 

•  Indoor motion sensor (60-639) 
• Outdoor 

motion 

sensor (60-639) 

•  Remote handheld touchpad (60-671) 

Contact your GE representative for a more complete list.

Caution: 

Do not use outdoor motion sensors for intrusion 

protection 

 

 

 

Table 1 below describes the recommended sensor groups. 

Table 1: Recommended sensor groups 

Device 

Recommended sensor group 

Indoor motion sensor 

17 

a

  

Outdoor motion sensor 

25 (chime only group) 

b

Entry/exit door 

10 

Interior door 

14 

Window sensor  

13 

Smoke sensor 

26 

c

Key fob 

01 

ELM key fob 

01 

Remote handheld touchpad 

01 

CO alarm 

34 

b

Freeze sensor 

29 

b

Water sensor 

38 

b

Personal help button 

01 

a. 

Not certified as a primary protection circuit for UL-listed 
systems and is for supplementary use only. 

b. 

Has not been investigated by UL. 

c. 

Required for UL-listed residential fire alarm applications. 

Installation 

Tabs at the top of the panel secure and release the front 
cover and the chassis. The plastic hinges on the panel 
bottom allow the cover and chassis to swing down and out 
of the way. 

To mount the panel on a wall: 

1.  Choose a panel location. 

2.  Run all necessary power, phone, siren, and hardwired 

contact wires to the desired panel location. 

Summary of Contents for Simon XT V2

Page 1: ... intrusion protection Table 1 below describes the recommended sensor groups Table 1 Recommended sensor groups Device Recommended sensor group Indoor motion sensor 17 a Outdoor motion sensor 25 chime only group b Entry exit door 10 Interior door 14 Window sensor 13 Smoke sensor 26 c Key fob 01 ELM key fob 01 Remote handheld touchpad 01 CO alarm 34 b Freeze sensor 29 b Water sensor 38 b Personal hel...

Page 2: ...nect hardwired reed switches normally closed loop only to HW1 I O if not being used for a hardwired siren an or HW2 in terminal 3 Connect only normally closed NC reed switches to HW1 I O and or HW2 in Other types of hardwired detectors should not be used The total resistance of the wired loop must not exceed 3 ohms This allows you to use up to 200 ft 61 m of two conductor 22 gauge stranded wire Co...

Page 3: ... end of the red battery lead to the red battery tab 2 Connect the lug end of the black battery lead to the black battery tab 3 Align the red battery terminal with the right end of the terminal strip The logo and specification information should be readable 4 Insert the front end of the battery under the forward battery compartment latch 5 Push forward and rotate the battery downward until it seats...

Page 4: ...vity if no access code has been entered yet After an access code has been entered to access a code protected area of the system menu the timeout is four minutes Menu navigation Each menu contains a list of options and or submenus Press the scroll buttons to navigate up and down the list of options and submenus in that menu Pressing OK after navigating to an option selects that option for editing a...

Page 5: ...panel memory The panel recognizes a sensor when you press a sensor program button press and release a tamper switch press a sensor test button or put a sensor into alarm Table 6 below describes the programming method for each device Note If you are installing a sensor on a gun case jewelry box or a similar case and the sensor is active in level one you must subdisarm to avoid putting the panel int...

Page 6: ...en all sensors have been tested the display shows SN Test Complete Press Status 3 Press Status The display shows Sensor Test OK If you press Status and the panel has not heard from all sensors the display shows SN Test Fail or Aborted Table 7 Sensor tripping instructions Sensor Do this Door window Open the secured door or window Freeze Remove the sensor cover Apply ice in a plastic bag to the sens...

Page 7: ... set to 5 minutes or more Trouble beeps set to on RF jam detect set to on Hardwired siren supervision set to on Exit extension set to off Quick exit set to off Household fire warning system UL 985 basic system plus the following Wireless smoke sensor 60 848 02 95 TX 6010 01 1 learned into sensor group 26 Panel piezo beeps turned on Control panel alarms set to on Siren timeout set to 4 minutes or m...

Page 8: ...allations Canadian standards CSA certified accessories Standard Class 2 9 VAC 3 34 A power transformer GE Security model 22 153 CN Residential burglary alarm system unit ORD C1023 1974 basic system as described for UL 1023 listed installations plus Hardwired magnetic contact 13 068 or 13 071 or wireless learn mode door window sensor 60 670 Siren timeout set to six minutes or more Residential fire ...

Reviews: