NX-592E-GSM Wireless Gateway

Installation Manual

4

Before installation

Before installing any Wireless Gateway, you must:

Create the Alarm.com customer account prior to installing the Wireless Gateway. 

E-mail 

[email protected]

 to become a registered Alarm.com dealer/installer. 

Create the account at least 24 hours before installation to ensure that the wireless module is activated properly 
on the wireless network.

Create a new account

To create a new account, do the following:

1. Open a web browser and enter the Alarm.com dealer website URL:

https://www.alarm.com/dealer

2. Enter your dealer login and password and press 

Go

.

3. Go to the 

Coverage/FAQ

 page to check wireless coverage at the install location. If the location has full 

coverage, proceed with the next steps. If coverage is uncertain, you may contact Alarm.com for more 
details.

4. Click the 

Customers

 link on the menu bar. Then click 

Create Customer

.

5. Enter the required customer information

6. Ensure the customer e-mail address is entered correctly. Alarm.com sends a confirmation message, and 

a list of account changes, to the customer via e-mail.

7. Click 

Next

Step Two, Create Customer’s Login

 will appear. Follow the directions as stated. You may 

click on 

Automatically Generate Login

 to have a login assigned to you.

8. Click 

Next

Step Three, System Location

 will appear. If the system is installed at the address provided 

at 

Step One Customer Information

, click 

Yes

. If the system is installed at an address different from the 

one provided in 

Step One Customer Information

, click 

No

 and enter the correct address and time zone 

where the system is to be installed. It is important that you enter the correct system location address at 
this step.

9. Click 

Next

Step Four Panel Information

 will appear. In the 

Modem Serial #

 dialog box, enter the 

10-character ID found on the gateway you purchased. If you are unable to proceed with the modem 
serial number, contact Alarm.com.

10. Select 

NX

 in the 

Panel Type

 list box.

11. Click 

Next

. The 

Confirmation

 screen will appear. Review the customer information. If you need to 

change any of the information, click the 

Edit

 link next to the field you want to update.

CAUTION:  

The website will issue a warning about the number of zones attached to the panel. Unlike Concord and Simon, 

the Alarm.com gateway cannot learn the number of zones from the panel. By default, the gateway will assume that 
eight zones are installed. If the number of zones is different, you will have to send a command to the panel later via the 
Customer Support page of the Dealer website. 

Summary of Contents for NX-592E-GSM

Page 1: ...g NX 592E GSM Wireless Gateway Installation Manual ...

Page 2: ...ctual businesses or persons is entirely coincidental Trademarks and patents GE and the GE monogram are registered trademarks of General Electric Company Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Intended use Use this product only for the purpose it was designed for refer to the data sheet and user d...

Page 3: ...n 6 Installation guidelines 6 Tools and supplies needed 6 Mounting locations 6 Mounting 7 Wiring connections 8 Case tamper switch installation 9 Power up 9 Enrolling the module 9 Programming using the keypad 10 Status LEDs 11 Specifications 12 Troubleshooting 12 Contacting us 13 Online resources 13 Creating a new subscriber account 14 Customer information 15 System operation from Alarm com 15 FCC ...

Page 4: ...NX 592E GSM Wireless Gateway Installation Manual iv ...

Page 5: ...n page 13 for instructions on accessing our online publication library Note A qualified service person complying with all applicable codes should perform all required hardware installation Conventions used in this document The following conventions are used in this document Safety terms and symbols These terms may appear in this manual Bold Menu items and buttons Italic Emphasis of an instruction ...

Page 6: ... from the Alarm com website Through a wireless two way paging network your customer has limited controls on such features as security notifications history and authentication see System operation from Alarm com on page 15 for further details Figure 1 NX 592E GSM Using the wireless paging network NetworX owners may also be notified of system events by e mail pager or phone ...

Page 7: ...le 1 Module component descriptions Component Function Bus LED Indicates data bus activity between panel and module Status LEDs Indicate communications status with two way pager network see Status LEDs on page 11 Wiring terminals Panel wiring connections see Wiring connections on page 8 Antenna jack Antenna connection for wireless data transceiver Bus LED Status LEDs Antenna jack Wireless data tran...

Page 8: ... the directions as stated You may click on Automatically Generate Login to have a login assigned to you 8 Click Next Step Three System Location will appear If the system is installed at the address provided at Step One Customer Information click Yes If the system is installed at an address different from the one provided in Step One Customer Information click No and enter the correct address and t...

Page 9: ...s section describes how to program the number of zones into the gateway To program the number of zones into the gateway do the following 1 Once the account is created log on to the Alarm com Dealer website at https www alarm com dealer 2 Click the Customers tab and then click the Customer Support subtab 3 Enter the name of the account in the Customer Search field and click Submit Search 4 Select t...

Page 10: ...hen using panel power for bus devices and hardwired sensors refer to your panel documentation Tools and supplies needed Slotted and Phillips screwdrivers Drill 3 8 drive and drill bits Wire cutter stripper Four conductor 22 gauge or larger stranded wire Modem Modem antenna and mounting screws included 6 panhead screws and wall anchors four each included Mounting locations Use the following guideli...

Page 11: ...re it is level and mark the three mounting holes and the wire access area see Figure 2 on page 3 Be sure to leave at least 12 to 18 in 30 to 45 cm above the backplate for the antenna 4 Drill holes at the mounting hole and wire access area locations 5 Install wall anchors and secure the module backplate to the wall with 6 panhead screws CAUTION You must be free of static electricity before handling...

Page 12: ...gure 4 Wiring connections CAUTION To prevent damage to the panel or module you must remove panel AC power and disconnect the backup battery prior to changing any wire connections Table 3 Terminal descriptions Terminal Description POS Connect to the KP POS terminal of the NetworX panel COM Connect to the KP COM terminal of the NetworX panel DATA Connect to the KP DATA terminal of the NetworX panel ...

Page 13: ... following 1 Verify that all wiring between the panel and module are correct 2 Reconnect the backup battery and restore panel AC power Enrolling the module The NetworX control panels automatically find and store in memory the presence of all keypads zone expanders wireless receivers output modules and any other device on the keypad bus allowing these devices to be supervised by the control panel T...

Page 14: ...he above procedure pressing the key without entering data first If you attempt to program an invalid entry for a particular segment the keypad sounder will emit a triple error beep beep beep beep and remain in that segment waiting for a valid entry 8 Press the Exit key to exit this programming level Press the Exit key again to exit Program Mode While in programming mode and not in a location the n...

Page 15: ...e Yellow ACK LED The yellow ACK LED indicates the module s message status On After the first message has been sent to and received by Alarm com services Off Until a message has been sent by the module Flashing While the first message is being sent by the module Green XMT LED The green XMT LED indicates the module s message status Off Iimmediately after Alarm com services has received a message Fla...

Page 16: ...ces The touchpads sirens are beeping even though the system is not armed Press 2 to display the trouble condition Refer to your touchpad documentation for details Compatibility NetworX panels Power requirements 9 5 to 15 VDC 12 V nominal 65 mA continuous 1600 mA instantaneous peak maximum from panel or auxiliary power supply Cellular network Quad Band GSM GPRS Power data bus One 3 wire NetworX pow...

Page 17: ...ms and Conditions Policy Statement Customer service and technical support From the Customer Support menu select Customer Service or Technical Application Select the appropriate product category for the contact information or use the menu to select a location outside the US Table 6 Technical support North America Latin America T 888 GE Security 888 437 3287 Toll free in the US Puerto Rico and Canad...

Page 18: ...ome Letter Confirmation number sent from Alarm com to your customer s e mail Complete list of system sensors and touchpads A phone number and e mail address for Alarm com to send notifications to After you have gathered the required information log on to the following address https www alarm com Log on by entering the correct login name and temporary password A New Subscriber Setup Wizard appears ...

Page 19: ...ns see the Alarm com website and click on the help tab in the category you have questions about FCC notice This device complies with parts 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Changes or modifications not ...

Page 20: ...NX 592E GSM Wireless Gateway Installation Manual 16 ...

Reviews: