3.
Disarm to Level 1 to exit Test Mode.
Phone Communication Test
The purpose of this weekly test is to verify that the connection between the central monitoring
station and your system are working properly.
Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to
establish a connection.
To perform a phone communication test:
1. Disarm the system.
2. Press
8
+ System or Partition Master
CODE
+
2
.
touchpads display, “
]
PHONE TEST” or “System Armed to PHONE TEST.”
3. If the phone test is successful:
the optional voice module will announce, “Phone Test OK.”
Within a few minutes, the display should return to the Level 1 display. If it does not return in
three minutes, note how long before the Level 1 display returns and contact the installer.
After the test has started, the arming level can be changed to 1—Off, then to 2—Stay or 3—
AWAY, if you wish.
Keychain Touchpad
Press and hold the Lock
and Unlock
buttons
simultaneously for 3 seconds.
•
Zones
nn
OK
•
TOUCHPAD
nn
OK
Press and hold the Star
and Light
buttons
simultaneously for 3 seconds.
•
Touchpad Panic AUXILIARY OK
•
AUXILIARY PANIC OK
Panic button
Press and hold the appropriate panic button(s) for 3
full seconds.
•
Zones
nn
OK
•
SENSOR
nn
OK
Door/window sensor
Open the secured door or window.
•
Zones
nn
OK
•
SENSOR
nn
OK
Smoke detector
Press and hold the test button until the system sounds
transmission beeps.
•
Zones
nn
OK
•
SENSOR
nn
OK
Motion detector
Avoid the motion detector view for 5 minutes, then
enter its view.
•
Zones
nn
OK
•
SENSOR
nn
OK
Rate-of-Rise Heat Detec-
tor (Not UL investigated)
Rub your hands together until warm, then place one
hand on the detector for 30 seconds.
•
Zones
nn
OK
•
SENSOR
nn
OK
Shock sensor
(Not UL investigated)
Tap the glass twice, away from the sensor. Wait at
least 30 seconds before testing again.
•
Zones
nn
OK
•
SENSOR
nn
OK
Phone Interface and
Voice Module
Activate a Police panic by accessing the system using
the phone and pressing
*
+
*
+
*
+
*
+
*
+
*
.
•
POLICE PANIC OK
Supervised wireless siren Unplug the siren and check the touchpad display.
Plug the siren in.
•
SENSOR
nn
OK
•
Zones
nn
OK
Glass guard sensor
(Not UL investigated)
Tap the glass 3 or 4 inches from the sensor.
•
Zones
nn
OK
•
SENSOR
nn
OK
Freeze sensor
(Not UL investigated)
Apply an ice cube wrapped in plastic to the sensor. Do
not allow the sensor to get wet.
•
Zones
nn
OK
•
SENSOR
nn
OK
•
If you need more time to complete testing, restart the timer by pressing
8
+
CODE
+
3
.
•
Check to see that all sensors have been tested by pressing
*
. Touchpads display a list of untested sensors.
•
You will know that you have finished testing when touchpads display, “SENSOR TEST OK” or “ZONES ALL
TESTED.”
Device
Test Procedure
Touchpad Result(s)
Summary of Contents for 60-792-01-95R