BOARD INSTALLATION

 

 

Inside the can, several 2-holed insertion points have been
constructed. This allows for either vertical or horizontal placement of
the modules. Notice that each insertion point has two sizes of holes -
a larger hole and a smaller hole.

Diagram 1: The black plastic PCB guides are grooved on one edge
where the PC board will be seated. The end with the half-moon
protrusion fits into the larger hole. The smaller hole is for the screw.

Diagram 2: Place the first black plastic PCB guide in the top insertion
point, grooved edge downward. The half-moon protrusion will be in
the large hole. It does not require force. Insert one of the provided
screw into the smaller hole (from inside the can) to secure it in place.
A screwdriver should reach through the notch that runs the length of
the guide to tighten the screw. The second PBC guide should be
positioned opposite the first (grooved edge up) and placed in the
lower insertion point, using the same procedures described above.
Once mounted, screw it in securely.

Diagram 3: The PC Board should slide freely in the grooves of both
guides.

K

 

IMPORTANT!
1.

If separate power supplies are necessary to accommodate additional devices, safety
standards require that each power supply be prominently marked with adequate instructions
for removing all power from the unit.

2.

Dispose of used batteries according to the manufacturer’s instructions and/or local
government authorities.

3.

Installation personnel should thoroughly read and understand the installation instructions and
the users manuals for the panel and all the accessories to be included with the system
before attempting to install a security system.

 

WARNING!
Replace only with Panasonic #LC12V4BP or Yuasa #NP4-12 battery. Observe polarity when
installing a new battery. Installing the battery backwards may cause damage to the panel. There
is a risk of explosion if the battery is replaced with an incorrect type.

 

NOTE
Electrical codes will vary depending upon the country and city where the system is installed. It is
the installer’s responsibility to ensure that the electrical installation is safe and conforms to all
applicable codes, laws, or regulations. Only qualified persons should connect this device to the
mains supply.

Summary of Contents for NetworX NX-8

Page 1: ...a 9 11 Enrolling the Modules Keypads 11 L Quick Start Installations 11 Communicator Formats 12 Reporting Events to Phone 1 2 3 12 15 Default Zone Types 18 Zone Doubling 21 Programming the Outputs 23 24 Programming Worksheets 37 50 SIA and Contact ID Formats 51 52 Expander Trouble Reporting Information 53 Wiring Diagram 54 Terminal Description 55 Telephone Interface Information 56 CE Notice Declara...

Page 2: ...ad 16 5V 25VA Transformer NX 8 NX 8 Control Only NX 108E 8 Zone LED Keypad NX 116E 16 Zone LED Keypad NX 124E 24 Zone LED Keypad NX 148E Alphanumeric LCD Keypad NX 200 Zone Doubling Kit Includes 100 3 74k and 100 6 98k resistors NX 216 16 Zone Expander Module NX 320 Smart Power Supply and Buss Extender NX 408E 8 Zone Wireless Expansion Module UL LISTED PART 60 904 NX 416E 16 Zone Wireless Expansio...

Page 3: ... 55 pages 17 and 25 NOTE For UL installations this feature shall be disabled Auto Cancel Abort If enabled the Cancel and or Abort features will be automatic pressing the Cancel button is not required The Cancel and Abort features in locations 23 and 40 respectively must be enabled to permit this Auto feature to work For proper operation of these features ADialer Delay must be enabled in the AChara...

Page 4: ...ing of any zones designated as Entry Guard zone will initiate the keypad sounder and start the entry delay before creating an alarm All other zones will function as normal This arming mode will encourage system owners to use their system more frequently when the premises are occupied See locations 111 149 pages 33 36 NOTE For UL installations this feature shall be disabled Exit Error If enabled th...

Page 5: ...mming of all locations or specified locations from the keypad See location 21 page 16 Log Full Report A report can be sent to the central station when the event log is full See location 37 page 21 Lost Clock Service Light The NX 8 can be programmed to illuminate the Service LED when the internal clock has an invalid time due to power loss See location 37 page 21 Manual Test The NX 8 can be program...

Page 6: ...ill be temporal See location 37 page 21 NOTE For UL installations do NOT disable Tone Sniff Answering Machine Defeat If enabled only one call is required to defeat the answering machine To use this feature you must have a Hayes 1200 Smart Modem or a Caddx 1200 module From the computer call the panel as normal When the answering machine answers the panel will hear the tones from the modem and seize...

Page 7: ...ble Armed Status Suppression will not allow the keypad to display faulted or bypassed zones when the system is armed 6 Enable Panic Fire Medical Beeptone will sound a short beep to verify that the keypress was accepted 7 Suppresses the Service LED NOTE For UL installations the Service LED shall not be suppressed will not allow the Service LED to illuminate for any reason If there is a system troub...

Page 8: ...7 Open Close Reporting 8 If this LED is on LEDs 1 7 will use the chart to the right 8 If this LED is off LEDs 1 7 use the chart to the left 3 Enter r The Instant LED will illuminate steady This moves you to the partition enable This tells the system what partition this user can arm disarm LEDs 1 8 illuminate for each partition that the user has authorization for To change any of these numbers pres...

Page 9: ...y to enter another programming location If an attempt is made to program an invalid entry for a particular segment the keypad sounder will emit a triple error beep beep beep beep and remain in that segment awaiting a valid entry EXITING THE PROGRAM MODE When all the desired changes in programming have been made it is time to exit the program mode Pressing the Exit key will exit this programming le...

Page 10: ...Page 10 PROGRAMMING EXAMPLE TO BE INSERTED HERE ...

Page 11: ...peaker is attached to the NX 8 it will click at this time If a siren or bell is attached to the NX 8 it will sound for about 1 second Once a module is enrolled if it is not detected by the control the Service LED will illuminate L QUICK START INSTALLATION For most routine installations the Quick Start option will allow for enabling a majority of the options available with the NX 8 when communicati...

Page 12: ... 1400hz handshake single round w parity 40 p p s hex capability 11 4 2 express 2 digit event code DTMF transmission 12 4 2 fast Two digit event code 1900hz transmit 1400hz handshake double round parity 20 p p s 13 Ademco Contact ID DTMF see pages 51 52 14 SIA FSK see pages 51 52 15 Custom format See location 18 page 16 REPORTING EVENTS TO PHONE NUMBER 1 Phone 1 has two programming locations that a...

Page 13: ... phone number is dialed L LOCATION 8 COMMUNICATOR FORMAT FOR PHONE 2 1 segment numerical data Location 8 contains the communicator format used to transmit to the receiver connected to Phone 2 Consult the instruction manual for your central station receiver to determine which format is compatible and select from the 15 formats listed on page 12 If you require a format other than those listed review...

Page 14: ...o Communicate 7 Reserved 8 Reserved LOCATION 11 PARTITIONS REPORTED TO PHONE 2 1 segment feature selection data Location 11 is used when events to be reported to a phone number are based upon the partition regardless of the event If this location is used location 10 should be 0 Segment 1 1 Partition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Partition 8...

Page 15: ...ocation 16 and location 17 should be left at the factory default of 0 If multi reporting or split reporting is desired and the split is based on the event type such as alarm open close etc then location 16 should be used to select only those events that should be reported to Phone 3 and location 17 should be left at the factory default of 0 If dual or split reporting is desired and the split is ba...

Page 16: ...ation See the feature definitions beginning on page 3 Segment 1 1 On enables two call answering machine defeat 2 On enables tone sniff answering machine defeat 3 On requires call back before download session 4 Shutdown can only be viewed from the keypad must be changed through downloading 5 On locks all local programming can only be viewed from the keypad must be changed through downloading 6 On l...

Page 17: ... feature 2 On enables the Require Code for Bypassing feature 3 On enables the Zone Bypassed Sounder Alert feature 4 On enables the AC Power Low Battery Sounder Alert feature 5 On enables Bypass toggle 6 On enables Silent Auto Arm 7 On enables the Automatic Instant feature 8 Reserved Segment 3 1 On enables Opening and Closing reports 2 On enables Zone Bypass reporting 3 On enables Zone Restore repo...

Page 18: ...ABLED This zone will be instant when the system is armed and no entry or exit delay is being timed It is delayed during entry and exit delay times If a Cross Zone is not being timed it will start a Cross Zone timer If a Cross Zone is being timed it will create an instant alarm This zone will automatically bypass when enabled in Segment 1 of Location 23 13 INSTANT ENTRY GUARD This zone creates an i...

Page 19: ...8 PARTITION SELECT ZONES 9 16 8 segments feature selection data Location 28 is used to select the partition s that zones 9 16 reside in A zone may reside in any combination of the 8 partitions If a burglary zone resides in more than 1 partition it will only be active when all partitions are armed A zone that resides in more than 1 partition will be reported to its lowest partition Location 28 has ...

Page 20: ...ion 34 is used to select the partition s that zones 33 40 reside in A zone may reside in any combination of the 8 partitions If a burglary zone resides in more than 1 partition it will only be active when all partitions are armed A zone that resides in more than 1 partition will be reported to its lowest partition Segment 1 corresponds to zone 33 and Segment 8 corresponds to zone 40 Segments 1 8 1...

Page 21: ... 6 On if Telephone Line Cut report enabled 7 On if Ground Fault Detection report enabled 8 On if Expander Trouble reporting enabled Segment 4 1 On if Fail To Communicate report enabled 2 On if Log Full report enabled 3 On if Autotest report enabled 4 On if Start End programming report enabled 5 On if End Download report enabled 6 On if Sensor Low Battery report enabled 7 On if Sensor Missing repor...

Page 22: ...CODE BEFORE EXITING PROGRAMMING 2 On requires code entry for r 9 8 perform call back download and r 9 9 answer incoming call for download functions 3 Enable Auto Cancel Abort Refer to feature definitions beginning on page 3 4 Enable Walk Test Mode Refer to feature definitions beginning on page 3 5 8 Reserved L LOCATION 42 GO TO PROGRAM CODE 6 segments numerical data Location 42 contains the Go To ...

Page 23: ... should be timed 3 On if output should stop timing upon code entry Off if the output should continue to time upon code entry 4 On if output should only activate between the closing and opening time in loc 52 and 53 5 On if output should only activate between the opening and closing time in loc 52 and 53 6 On if output should be inverted 0 volts going to 12 volts when activated 7 Reserved 8 Reserve...

Page 24: ...er current 15 Keypad Tamper 41 Box Tamper 16 Autotest 42 Siren Tamper 17 Alarm Memory 43 Any Open 18 Entry 44 Any Short 19 Exit 45 Any Fault Open Short on Non Fire Zone 20 Entry or Exit 46 Any Alarm 21 Armed State 47 Beeping Keypad 22 Disarmed State 48 Code Entry See note below 23 Ready 49 Key FOB Function 1 24 Not Ready 50 Key FOB Function 2 25 Fire Events 49 50 require NX 408 NX 416 or NX 448 wi...

Page 25: ...ime for Auto Arm Aux Outputs or Code Authorization to function properly Segment 1 Program the hour of the closing auto arm time Segment 2 Program the minutes after the hour of the closing auto arm time LOCATION 54 DAYS OF THE WEEK EACH PARTITION IS OPEN 8 Segments feature selection data Location 54 selects which days of the week each partition is open On these days Aarm only after close window cod...

Page 26: ...contains the event code for a zone Bypass for a 4 2 format The digit programmed in this location will be sent as the tens digit The zone ID will always be reported as the ones digit of the zone number i e 9 for zone 29 This location contains 8 segments Any segment left as 0 will follow the Segment 1 selection Segment 1 Partition 1 Bypass Code Segment 2 Partition 2 Bypass Code Segment 3 Partition 3...

Page 27: ... MISSING COMMUNICATOR CODE SLOW SPEED FORMATS ONLY 8 segments numerical data Location 61 contains the event code for a zone Sensor Missing for a 4 2 format The digit programmed in this location will be sent as the tens digit The zone ID will always be reported as the zone number i e 9 for zone 29 Any segment left as 0 will follow the Segment 1 selection Segment 1 Partition 1 Sensor Missing Code Se...

Page 28: ...t of the Low Battery Restore Segment 4 contains the ones digit of the Low Battery Restore LOCATION 70 AUX POWER OVERCURRENT AUX POWER OVERCURRENT RESTORE COMMUNICATOR CODES SLOW SPEED FORMATS ONLY 4 segments numerical data Location 70 contains the tens and ones digits for a 4 2 format that will be sent if Aux Power Overcurrent Reporting is enabled Segment 1 contains the tens digit of the Aux Power...

Page 29: ...4 Opening Code for Partition 4 Segment 5 Opening Code for Partition 5 Segment 6 Opening Code for Partition 6 Segment 7 Opening Code for Partition 7 Segment 8 Opening Code for Partition 8 LOCATION 78 CLOSING COMMUNICATOR CODE SLOW SPEED FORMATS ONLY 8 segments numerical data Location 78 contains the tens digit of a 4 2 format if the Closing Reporting is enabled The ones digit is the ones digit of t...

Page 30: ...er the last digit of the account code If the account code is 6 digits long program all 6 segments LOCATION 89 ACCOUNT CODE FOR PARTITION 2 6 segments numerical data Location 89 contains the account code sent when partition 2 is reported If location 89 is left unprogrammed all A10 s then the account code corresponding to the Phone number dialed will be used If the account code is less than six digi...

Page 31: ...lank nothing enabled the features for partition 1 will be used LOCATION 97 PARTITION 4 ENTRY EXIT TIMERS 4 segments numerical data Location 97 is used to enter in seconds the Entry and exit times There are 2 separate entry and exit times Valid entries are 10 255 seconds If all segments are A0 the entry and exit times for partition 1 will be used Segment 1 Entry time 1 Entry time that will be used ...

Page 32: ...unt code is 6 digits long program all 6 segments LOCATION 105 PARTITION 7 FEATURE AND REPORTING SELECTIONS 3 segments feature selection data Location 105 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system In addition certain communicator reports are enabled in this location Each of these features can be enabled by partition This locatio...

Page 33: ...uld Automatically Bypass or Bypass for Stay Arming 8 Local only turn on if this zone should not be reported Segment 2 1 On if Zone Type will beep the keypad for alarm 2 On if Zone Type will sound the yelping siren for alarm 3 On if Zone Type will sound the temporal siren for alarm 4 On if Zone Type will chime 5 On if Zone Type can be bypassed 6 On if Zone Type is included in the group shunt 7 On i...

Page 34: ...ata Location 122 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 52 The zone ID will be that zone that is in alarm If 4 2 format is being used the number programmed in this location will be sent as the tens digit When using 4 2 the digit in location 122 should be from 1 15 The zone ID for 4 2 formats will be the ones digit o...

Page 35: ...f the zone that is in alarm LOCATION 135 ZONE TYPE 13 CHARACTERISTIC SELECT 3 segments feature selection data Use Zone Type Characteristic Selections described in Location 111 page 33 LOCATION 136 ZONE TYPE 14 ALARM EVENT CODE 1 segment numerical data Location 136 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 52 The zone I...

Page 36: ...egments feature selection data Use Zone Type Characteristic Selections described in Location 111 page 33 LOCATION 146 ZONE TYPE 19 ALARM EVENT CODE 1 segment numerical data Location 146 contains the event code sent for a Contact ID or SIA report The desired event code should be chosen from the list on page 52 The zone ID will be that zone that is in alarm If 4 2 format is being used the number pro...

Page 37: ... Fault Sensor Lost Sensor Low Battery Expander Trouble Failure To Communicate Reserved Reserved PHONE 1 SELECTING WHICH PARTITIONS REPORT TO PHONE 1 Segment 1 Circle Numbers To Program 5 13 1 2 3 4 5 6 7 8 Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 L 6 13 PHONE 2 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 __ __ __ __ __ __ __ __...

Page 38: ...ouble AC Failure or Low Battery Siren Telephone Fault Test Reports Program Download Log Full 1 2 3 4 5 6 7 8 Tampers Short Circuit Ground Fault Sensor Lost Sensor Low Battery Expander Trouble Failure To Communicate Reserved Reserved PHONE 3 SELECTING WHICH PARTITIONS REPORT TO PHONE 3 Segment 1 Circle Numbers To Program 17 15 1 2 3 4 5 6 7 8 Partition 1 Partition 2 Partition 3 Partition 4 Partitio...

Page 39: ...5 6 7 8 Quick Arm Re Exit Auto Bypass Silent Panic Audible Panic Auxiliary 1 Auxiliary 2 Multi Keypress Tamper 1 2 3 4 5 6 7 8 LED extinguish enable Require user code for bypassing zones Bypass sounder alert AC power low battery sounder alert Enables bypass toggle Enables silent auto arm Enables automatic instant Reserved 1 2 3 4 5 6 7 8 Open Close Bypass Restore Trouble Tamper Cancel Recent Closi...

Page 40: ...2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L 31 20 ZONES 25 32 ZONE TYPES 6 6 6 6 6 6 6 6 _ _ _ _ _ _ _ _ ZONES 25 32 PARTITION SELECTION Segment 1 Zone 25 thru Segment 8 Zone 32 Segments 1 2 3 4 5 6 7 8 32 20 Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 1 2 3 4 5 6...

Page 41: ...for keyswitch arming two times for disarming Segment 2 Circle numbers to program 1 2 3 4 5 6 7 8 Convert siren driver to voltage out Siren sounds for expander trouble required for U L Immediate Restore by zone Dynamic battery test performed upon arming Battery missing test performed every 12 seconds Manual bell test performed during r 4 test function Manual communicator test performed during r 4 t...

Page 42: ...me Keypad sounds for Tamper Alarm Reserved Keypad sounds for expander trouble required for UL SYSTEM TIMERS Segment 1 Dynamic Battery Test duration 0 255 minutes 0 _ Segment 2 AC Failure report delay 0 255 minutes 5 _ Segment 3 Power Up Delay 0 60 seconds 0 _ Segment 4 Siren Time 1 255 minutes 8 _ Segment 5 Telephone Line Cut delay 0 255 seconds 0 _ Segment 6 Cross Zone Time 0 255 minutes 5 _ Segm...

Page 43: ...3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 46 23 AUXILIARY OUTPUTS 1 4 SPECIAL TIMING Segments 1 2 3 4 Auxiliary output timed in minutes Auxiliary output to latch Auxiliary output to stop timing upon user code entry Auxiliary output to activate only between closing and opening time Auxiliary output to activate only ...

Page 44: ...YS OF THE WEEK EACH PARTITION IS OPEN Segments 1 2 3 4 5 6 7 8 54 25 Sunday Monday Tuesday Wednesday Thursday Friday Saturday Reserved 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 DAYS OF THE WEEK AUTO ARMING WILL OCCUR IN PARTITIONS 1 8 Segments 1 2 3 4 5 6 7 8 55 25 Sunday Monday Tuesday Wednesday Thursday Friday ...

Page 45: ...uble Code 0 _ Segment 4 Partition 4 Trouble Code 0 _ Segment 5 Partition 5 Trouble Code 0 _ Segment 6 Partition 6 Trouble Code 0 _ Segment 7 Partition 7 Trouble Code 0 _ 59 27 Segment 8 Partition 8 Trouble Code 0 _ SENSOR LOW BATTERY COMMUNICATOR CODE SLOW SPEED FORMATS ONLY Segment 1 Partition 1 Sensor Low Battery Code 0 _ Segment 2 Partition 2 Sensor Low Battery Code 0 _ Segment 3 Partition 3 Se...

Page 46: ... Opening Code for Partition 2 0 _ Segment 3 Opening Code for Partition 3 0 _ Segment 4 Opening Code for Partition 4 0 _ Segment 5 Opening Code for Partition 5 0 _ Segment 6 Opening Code for Partition 6 0 _ Segment 7 Opening Code for Partition 7 0 _ 77 29 Segment 8 Opening Code for Partition 8 0 _ CLOSING COMMUNICATOR CODE Segment 1 Closing Code for Partition 1 0 _ Segment 2 Closing Code for Partit...

Page 47: ...nable Require user code for bypassing zones Bypass sounder alert AC Power Low Battery sounder alert Enables Bypass toggle Enables Silent Auto Arm Enables Automatic Instant Reserved 1 2 3 4 5 6 7 8 Open Close Bypass Restore Trouble Tamper Cancel Recent Closing Exit Error PARTITION 3 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Time 1 0 _ Segment 3 Entry Time 2 0 _ 94 31 Segment 4 Exi...

Page 48: ...able Require user code for bypassing zones Bypass sounder alert AC Power Low Battery sounder alert Enables Bypass toggle Enables Silent Auto Arm Enables Automatic Instant Reserved 1 2 3 4 5 6 7 8 Open Close Bypass Restore Trouble Tamper Cancel Recent Closing Exit Error PARTITION 6 ENTRY EXIT TIMERS Segment 1 Entry Time 1 0 _ Segment 2 Exit Time 1 0 _ Segment 3 Entry Time 2 0 _ 103 32 Segment 4 Exi...

Page 49: ...2 Entry Exit times Interior Enable for auto bypass or stay arming Local Only enable if zone is not to be reported Segment 2 Circle numbers to program 1 2 3 4 Keypad audible on alarm Yelping siren on alarm Temporal siren on alarm Chime 5 6 7 8 Bypassable Group Shunt Force armable Entry Guard Segment 3 Circle numbers to program 1 2 3 4 Fast Loop Response Double End of Line Tamper zone Trouble zone D...

Page 50: ...ONE TYPE 14 CHARACTERISTIC SELECT 5 12456 5678 138 35 ZONE TYPE 15 ALARM EVENT CODE 5 _ 139 35 ZONE TYPE 15 CHARACTERISTIC SELECT 457 1256 5678 140 35 ZONE TYPE 16 ALARM EVENT CODE 4 _ 141 35 ZONE TYPE 16 CHARACTERISTIC SELECT 0 12456 5678 142 36 ZONE TYPE 17 ALARM EVENT CODE 7 _ 143 36 ZONE TYPE 17 CHARACTERISTIC SELECT 5 1245 25678 144 36 ZONE TYPE 18 ALARM EVENT CODE 5 _ 145 36 ZONE TYPE 18 CHA...

Page 51: ...device number 309 YT LOW BATTERY RESTORE device number 309 YR AC FAIL device number 301 AT AC RESTORE device number 301 AR BOX TAMPER device number 137 TA BOX TAMPER RESTORE device number 137 TR KEYPAD TAMPER 137 TA KEYPAD PANIC audible 120 PA KEYPAD PANIC silent 121 HA DURESS 121 HA KEYPAD AUXILIARY 1 110 FA KEYPAD AUXILIARY 2 100 MA RF SENSOR LOST zone number 381 T RF SENSOR RESTORE zone number ...

Page 52: ...Periodic Test 15 GA Gas Alarm 16 KA Heat Alarm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm The NX 8 has the ability to report Ademco Contact ID transmissions Each report in Contact ID consists of an Event Code and a Zone ID The zone ID is the zone that created the alarm The event code will come from the chart below and be programmed in the zone type event code ...

Page 53: ... 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 HARDWIRE EXPANDER NX 216 OUTPUT MODULE NX 508 NX 508E Starting zone number Expander reported Address Dip Switch Setting Zone 9 All switches off 22 24 Switch 1 2 on Zone 9 Switch 1 on 23 25 Switch 3 on Zone 17 Switch 2 on 16 26 Switch 1 3 on Zone 25 Switch 1 2 on 17 27 Switch 2 3 on Zone 33 Switch 3 on 18 28 Switch 1 2 3 on Zone 41 ...

Page 54: ...Page 54 NX 8 WIRING DIAGRAM For CE labeled products please refer to page 57 for specific electrical requirements ...

Page 55: ...y zone to be used with smoke detectors COM Connect negative wire of powered devices such as motion detectors and smoke detectors AUX PWR Connect positive wire of all powered devices except smoke detectors and keypads This terminal and KP POS are limited to 1 amp total current when added together ZONE 8 Connect to one side of zone 8 loop Connect the other side to com terminal Open or short causes a...

Page 56: ...orrect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communications facilities equipment operations or procedures where such action is reasonably required and proper in its business Should any such change render the custom...

Page 57: ...the countries marked with a check and may have interworking problems with the countries that are not checked Due to the inherent differences in the individual PSTNs certain software settings may need to be adjusted on a country to country basis If it is desired to use this equipment on a network other than the one on which it was originally installed you should contact your equipment supplier Aust...

Page 58: ...l burglary applications the maximum entry and exit delay times shall be 45 and 60 seconds respectively The exit delay time shall not exceed 60 seconds for commercial burglar alarm applications The keyswitch option shall not be used The telephone line monitor shall be enabled The Telephone Line Cut delay shall not exceed 90 seconds 24 hour communicator test transmission is required For 24 hours of ...

Page 59: ...curely Diagram 3 The PC Board should slide freely in the grooves of both guides K IMPORTANT 1 If separate power supplies are necessary to accommodate additional devices safety standards require that each power supply be prominently marked with adequate instructions for removing all power from the unit 2 Dispose of used batteries according to the manufacturer s instructions and or local government ...

Page 60: ...Page 60 SYSTEM NOTES ...

Page 61: ... DRIVER 2 tone Temporal and Yelp LOOP RESPONSE Selectable 50mS or 500mS OPERATING TEMPERATURE 32 to 120 degrees F LED KEYPAD Current Draw 130 mA max Zones Normal w o Sounder 55 mA Dimensions 6 4 Wide 4 0 High 1 1 Deep NX 148 LCD KEYPAD Current Draw 110 mA max w o Sounder 75 mA Dimensions 6 4 Wide 5 3 High 1 0 Deep METAL ENCLOSURE DIMENSION 11 25 Wide 11 25 High 3 50 Deep SHIPPING WEIGHT 9 lbs 1420...

Reviews: