29
Programming the Panel
The following describes how to program the settings that
appear under SIREN OPTIONS—PARTITION 1
Sensors Menu
The SENSORS menu gives you access to the following:
LEARN SENSORS—lets you learn hardwire zones and
wireless sensors into panel memory and assign zones/
sensors to specific partitions.
SENSOR TEXT—lets you program sensor text for
zone/sensor identification.
DELETE SENSORS—lets you delete zones/sensors
from panel memory.
EDIT SENSORS—lets you view and/or change sensor/
zone group assignment, view sensor number and text
assignments of learned sensors/zones, identify whether
zone is wireless or hardwire, and indicates sensor/zone/
touchpad input N/C or N/O configuration.
The following describes how to program the sensor settings
that appear under LEARN SENSORS.
Ìi
If 2-wire smoke detectors are connected to hardwire
zone input 6, the TWO-WIRE SMOKE setting must be
turned on
before
entering the LEARN SENSORS
menu. See
ONBOARD OPTIONS—INPUTS
later in
this section.
.
Siren Verify
(Siren Options—Partition 1)
(0610)
(Default = off) This setting determines whether or not the
panel monitors sirens connected to panel terminal 7
(OUT1/+12V).
When this feature is on, sirens connected to panel terminals
3 (GND) and 7 (OUT1/+12V) require a 2k end-of-line
resistor. Refer to “Installing the System—Connecting
Sirens” for complete details.
Ìi
For UL Listed systems, this feature must be on.
To turn Siren Verify off or on:
With the display showing SIREN VERIFY OFF/ON
(current setting), press
1
(off) or
2
(on). The display
flashes the entered setting. Press
ƒ
and the display
shows the new setting.
Learn Sensors
(Sensors)
(070)
(Default = none) The following describes how to learn
hardwire zones and wireless devices into panel memory.
The panel comes with six factory programmed onboard
harwire zones. The factory programmed setting are listed
below:
Zone 1: 10-Entry/Exit
Zone 2: 17-Instant Interior Follower
Zone 3: 13-Instant Perimeter
Zone 4: 13-Instant Perimeter
Zone 5: 13-Instant Perimeter
Zone 6: 13-Instant Perimeter
Ìi
Clearing panel memory also clears all factory pro-
grammed zones.
Install an end-of-line resistor on all unused, factory
programmed, onboard panel zones
OR
Delete the unused zone from panel memory (see
“Delete Sensors (Sensors)” on page 30).
To Learn Sensors into panel memory:
1.
With the display showing SENSORS, press
ƒ
and the
display shows LEARN SENSORS.
2.
Press
ƒ
and the display shows SENSOR GROUP 0.
3.
Enter the desired 2-digit sensor group +
ƒ
(see
Appendix A for a description of all sensor group char-
acteristics). The display shows TRIP SENSOR nn,
where nn is the displayed (next available) sensor num-
ber.
4.
To change the displayed sensor number, enter the
desired 2-digit sensor
ƒ
.
5.
With the desired sensor number displayed, trip the sen-
sor or zone as follows:
q
Hardwire Zones—trip the zone into the alarm state.
q
Wireless Sensors—follow the instructions included
with each sensor.
Wireless Door/Window Sensors with External Con-
tacts—place the external contact in the alarm condi-
tion, then activate the sensor tamper switch.
q
Handheld Wireless Touchpads—press and hold the
BYPASS button until the touchpad LED flashes.
q
Keychain Touchpads—press and hold the lock and
unlock buttons together until the touchpad LED
flashes.
q
ELM Keychain Touchpads—a.) Press and release
the unlock button twice quickly, then press and hold
until the LED flashes three times. b.) Press and release
the unlock button once quickly, then press and hold
until the LED flashes two times. c.) Press and hold the
unlock button until the LED flashes once.
6.
Continue tripping sensors to learn them into the
selected sensor group. To stop learning sensors into a
group, press
‚
twice and start again from step 1
(LEARN SENSORS) to learn sensors into another
group (or use the EDIT SENSORS menu to change
group assignment after learning the sensor/zone).