10
Installing the System
Connect 2x16 and fixed display LCD touchpads to the
panel power output and bus terminals as shown in Figure
17.
Figure 17. Connecting 2x16 Alphanumeric and Fixed Display
LCD Touchpads
The 2x20 LCD/VFD touchpads include a supervised hard-
wire input for connection to a hardwire detection device
(see Figure 18 for an example of a normally closed connec-
tion).
Connect 2x20 LCD/VFD touchpads to the panel power out-
put and bus terminals as shown in Figure 18.
Figure 18. Connecting 2x20 LCD/VFD Touchpads
Installing an RJ-31X Phone Jack (13-081)
Use the following guidelines when installing an RJ-31X
phone jack for system control by phone and central station
monitoring.
Locate the RJ-31X jack (CA-38A in Canada) no further
than five feet from the panel.
The panel must be connected to a standard analog
(loop-start) phone line.
Ìi
The panel cannot be used on a digital or PBX phone
line. These systems are designed only for digital type
devices that operate anywhere from 5 volts DC and
up. The panel uses an analog modem and does not
have a digital converter, adapter, or interface to oper-
ate with such systems.
For full line seizure, install an RJ-31X phone jack on
the premises phone line so the panel is ahead of all
phones and other devices on the line. This allows the
panel to take control of the phone line when an alarm
occurs even if the phone is in use or off-hook.
If an analog line is not available, contact your custom-
ers’ telecommunications specialist and tell him/her you
need an analog line off the phone switch (PBX main-
frame) or a 1FB (standard business line).
Ìi
Connecting the panel to an analog line off the phone
switch places the panel
ahead
of the phone system
which prevents panel access from phones on the pre-
mises. However, the panel can still be accessed from
off-site phones.
To connect a phone line to the panel using an
RJ-31X/CA-38A jack:
1.
Run a 4-conductor cable from the TELCO protector
block to the jack location (see
A
in Figure 19).
2.
Connect one end of the cable to the jack (see
B
in Fig-
ure 19).
3.
At the TELCO protector block, remove the premises
phone lines (lines from phone jacks on premises) from
the block and splice them to the black and white (or
yellow) wires of the 4-conductor cable (see
C
in Fig-
ure 19).
4.
Connect the green and red wires from the 4-conductor
cable to the TIP (+) and RING (-) posts on the block
(see
D
in Figure 19).
3
4
5
6
SUPERBUS 2000 2X16
LCD ALPHANUMERIC
OR
SUPERBUS 2000
FIXED ENGLISH
LCD TOUCHPAD
G
N
D
/BLAC
K
+12V/
R
ED
BU
S
A/
G
R
EE
N
BU
S
B/
W
H
IT
E
8642G14A.DSF
+12V
A
B
GND
BUS
3
4
5
6
GND
+12V
BUS B
BUS A
PANEL
TERMINALS
NOT
USED
OPTIONAL SWITCH
WITH MAGNET
YELLOW (2)
BLA
C
K
RED
WHI
T
E
GREE
N
TOUCHPAD
WIRING HARNESS
(49-430)
8642G37A.DSF
2k Ohm EOL
RESISTOR 49-454
(Locate At Last Device)