– 25 –
Oven Sensors
The current software version of the main logic board will cause the cooktop to become inoperative if either of
the sensors open.
If either sensor opens and the fault code sets to epprom memory (this takes about 3 min.), the cooktop will
become inoperative until the sensor is replaced.
Upper Oven
room temp 1080 ohms
J501
Sensor
Pins 1, 2 (white/black)
clean temp 2650 ohms
Lower Oven
room temp 1080 ohms
J502
Sensor
Pins 1, 3 (white/red)
clean temp 2650 ohms
Relay Board Voltages
Legend for Ladder Wiring Diagram
g
g
g
Relays and connectors that begin with
are located on
MK, MJ
RPSM MAIN board
DK, DJ
Daughter relay board
AK, AJ
RPSM AUX board
NOTE:
Pin 1 on RPSM boards has a square solder pad.
Upper Oven
DK18-
DK3-NO DK3-NC COM DK18-NO
MJ7-2 DK7-COM
MJ7-1 MJ7-12
to L2
to L2
to L2
to L2
to L2
to L1
to N
to L1
Standby
0
240VAC 240VAC
0
0
120VAC
0
0
Broil, Upper*
240VAC
0
0
0
240VAC
240VAC
0
–
Bake, Upper*
0
240VAC 240VAC
240VAC
240VAC
240VAC
0
–
Door Motor, Upper
0
240VAC 240VAC
0
0
120VAC
120VAC**
–
Oven Lamp, Upper
–
–
–
–
–
–
–
120VAC**
*When calling for heat
**When motor or light is on
Lower Oven
MK3-NO MK3-NC MK7-COM MK7-NO
MK7-NC
MK10-COM MK10-NO
MK14-COM
to L2
to L2
to L2
to L2
to L2
to L2
to L2
MJ7-4 to L2
to L1
DJ-24 to N
DJ6-1 to N
DJ6-3 to N MJ7-8 to L1 DJ6-7 to N
Standby
0
240VAC
240VAC
0
240VAC
240VAC
0
0
120VAC
0
0
0
0
0
Broil , Lower*
240VAC
0
0
0
0
0
0
240VAC
240VAC
0
0
0
–
0
Bake , Lower*
0
240VAC
240VAC
240VAC
0
0
0
240VAC
240VAC
0
0
0
–
0
Convect , Lower*
0
240VAC
240VAC
0
240VAC
240VAC
240VAC
240VAC
240VAC
See Convect Fan.
–
0
Conv Fan CW
See Convect Element.
120VAC
120VAC
0
–
0
Conv Fan CCW
See Convect Element.
120VAC
0
120VAC
–
0
Oven Lamp, Lower
–
–
–
–
–
–
–
–
–
–
–
–
120VAC** 0
Door Motor, Lower
0
240VAC
240VAC
0
240VAC
240VAC
0
0
120VAC
0 0
0
–
120VAC**
*When calling for heat
**When motor or light is on
Cooktop Voltage Table
AK2-COM
AKB-NO
AK13-NO
AK11-NO
AK5-NO
AK6-COM
AK1-NO
AK4-NO
AK10-COM
AK14-COM
(J3) to L2
(J7-3) to L2
(J7-1) to L2
(J7-2) to L2
(J7-4) to L2
(J6) to L2
(J7-12) to L2
(J7-8) to L2
to L1
to L1
Standby
0
0
0
0
0
0
0
0
120VAC
120VAC
Only RF, all rings*
240VAC
240VAC
240VAC
0
0
0
0
0
240VAC
120VAC
Only RR*
0
0
0
240VAC
0
0
0
0
240VAC
120VAC
Only LF, all rings*
0
0
0
0
0
0
240VAC
240VAC
120VAC
240VAC
Only LR
0
0
0
0 0
240VAC
0
0
120VAC
240VAC
Only Center*
0
0
0
0
240VAC
0
0
0
120VAC
240VAC
*Use HIGH setting to test.