The variable speed drive unit will, ramp up the speed of the operator and then ramp down prior to closing. 
It must be remembered that the limit switches are to be set in a position which initiates the ramp down time. 
Therefore, the limit switches need to operate much sooner than when there is no variable speed drive unit. 

 

The accelerate and decelerate times have been set in the factory for the normal installation but can be changed if 
necessary. Similarly, the speed that the gate operates at has also been set but can be changed (up to approx 70Hz). 

 

NOTE changing the speed will change the position the gate will end up in its fully closed and open position.  
(Unless limit switch cams are also adjusted accordingly). 

Accelerate time (FN01)   

5 sec 

Decelerate time (FN02)   

2.5 sec 

Closing Speed (FN08)   

40Hz 

Running Frequency 

 

60Hz 

 

To change accelerate time:  Press DSP/FUN button 

Use arrows to select FN01 
Press DATA/ENT 
Use arrows to select new time 
Press DATA/ENT 
Press DSP/FUN 

 

To change decelerate time: as above except select FN02 

 

To change closing speed: as above except select FN08.  If opening speed and closing speed is to be the same, 
remove wire link between REV and SP1 terminals on invertor. 

 

To change opening speed of operator: when display is flashing and showing Hz, use arrows to raise or lower the 
Hz figure. 
NOTE frequency upper limit has been set to 70Hz. 

 

5.

            

C

OMMISSIONING

 

 

 

  Check that the limit switches are the correct way around by observing that the M1 op and cl  

       indicator led`s go out when the corresponding limit switch is activated.  If they are the wrong 
       way around, swap over the M1 op and cl limit wires.  They can be roughly set so they activate  
       approx 500 to 800mm before the gate reaches its end stops.  Final adjustments can be made  
       later.                                

 

Position the gate halfway and turn the knurled knob clockwise until the clutch is firm enough that the gate will 
drive, but the clutch will slip if it hits something at high speed. 

 

 If dual gates

, u can  leave one side disconnected (by putting both cams on limit switches) so adjustment can be  

made easier without having to keep an eye on both gates at once. 

 

Power up board and with gate in the half way position, press the opn or cls buttons to drive the gate 

 

The corresponding ( green for open and red for close) led should start to flash, if they are the wrong way around, 
turn power off to the operator, wait until the inverter powers down, then swap over any 2 of the motor phase wire 
at the inverter.  Turn power back on and test. 

 

Run the gate again fully in each direction checking the limit switch positions. 

 

Limit switches initiate the ramp down time so should not switch off the gates too soon (before reaching 
conversely not too late, so the torque limiter is operating.  Any speed or ramp time adjustments made from now 
on will affect the final stop position of gate. 

 

Tighten clutch ( torque limiter) knurled knob. 

 

   Set open & closed travel time as detailed in 

Setting Cycle Timers & Auto Close Times 

section.

 

 

Check that all safety devices work as designed.  

 

Install cover using screws provided in the front and sides to hold cover firm. 

 

Provide full details to the owner concerning the operation and relevant maintenance and disconnect 
details. 
 

 
 
 
 

Summary of Contents for 450L

Page 1: ...ity imported components Installation and Maintenance Manual Sliding Gate Operators Models GDS 450L 630L Range Made in Australia from Australian quality imported components A B N July N14870 Installation and Maintenance Manual Sliding Gate Operators Made in Australia from Australian quality imported components ...

Page 2: ...n the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freely over the pinion wheel any tights spots should be corrected by adjusting the rack height Check the operator is firmly bolted down to the concrete pad Ensure stops are installed on the gate for the f...

Page 3: ...the gate travels is in accordance with the opening and closing status LED s if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening speed closing speed and ramp times Automation settings operating modes are able to be adjusted via the CB6 board refer to manual for further instructions Once Inverter settings are appropriately set ...

Page 4: ... Precautions 5 2 Wiring Requirements 6 3 Installation Details 6 10 Electrical cabling Mechanical installation Electrical connections Operator dimensions CB 6 control board layout Inputs Outputs Mode descriptions 4 Variable Speed Drive VSD 10 5 Commissioning 11 6 Control Diagrams 12 ...

Page 5: ...gateposts or mounting structure has the necessary strength and rigidity to support the operator and the load of the opening and closing gate motion Always incorporate the appropriate Photo Electric Cells Induction Loops and any other safety devices to protect both equipment and personnel Extra caution should be employed when using operator in auto Display any necessary signs to indicate any danger...

Page 6: ...osed positions These stops need to be engineered and installed such that they will be strong enough to stop the gate should the limits fail at any time Remove the gate operator cover and position mounting plate and operator in approximate mounting location Use the rack to locate the operator the correct distance away from the gate rail finer adjustment can be made after Dynabolt or chemical anchor...

Page 7: ...7 Operator Dimensions ...

Page 8: ...iver 7 Motor 2 Limit Switch Inputs no t shown 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface 9 Pedestrian Access Control Input Connector 10 Open Stop Close Control Input 23 Input Status L E Ds 11 Close Control Input 24 Stop Input Jumper 12 Stop Control Input 25 Open Input Jumper 13 Open Control Input 26 PE Beam I...

Page 9: ... din rail to switch the 12 volts to an electric lock if fitted The load switched by the lock output terminals must not exceed 30v AC DC 5Amps If a electro magnetic lock is used change one wire on the control board lock output to the normally closed output Use the light relay module if fitted to switch the applied voltage to a light The load switched by the light relay module must not exceed 240v A...

Page 10: ...ut also resets the P E triggered auto close mode so that the P E input will need to be triggered again before a P E auto close cycle will be initiated Position 5 M 2 OUTPUTS STATUS OFF The M2 output controls second motor ON The M2 output controls status lights Position 6 P E STOPS CLOSE CYCLE OFF Activating the P E input while motors are closing causes the motors to reverse ON Activating the P E i...

Page 11: ...ator led s go out when the corresponding limit switch is activated If they are the wrong way around swap over the M1 op and cl limit wires They can be roughly set so they activate approx 500 to 800mm before the gate reaches its end stops Final adjustments can be made later Position the gate halfway and turn the knurled knob clockwise until the clutch is firm enough that the gate will drive but the...

Page 12: ......

Page 13: ...opened by hand To re engage the clutch move the gate by hand Into approx The half way position and turn the Knurled knob clockwise until it is very tight If when turning the knurled knob clockwise and It just spins either try spinning it clockwise with more force to release it off of the hexagonal retaining nut or hold the nut with one hand and turn the knurled knob clockwise ...

Page 14: ...G Failure to maintain equipment may result in injury or death and or damage to property and equipment Recommended maintenance to be performed on the operator and gate are as follows Operator performs over 150 cycles a day each month Operator performs between 100 150 cycles a day every 2 month 99 cycles a day every 4 months 49 cycles a day every 6 months Operator performs under 20 cycles a day ever...

Page 15: ...circumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not authorised to do so iv In respect of loss or damage caused by rough treatment v If the product is not used and maintained in accordance with instructions or recommendations listed in this Installati...

Reviews: