background image

 

 

 

 

 

 

GENERAL INFORMATION 

 

Thank you for purchasing this GDI Communications LLC. product. The NT200R-PLUS 
provides reliable, high-speed, Internet access to your existing phone line. There is 
no special wiring or special networking knowledge required. This modem is 
capable of data rates hundreds of times faster than a traditional analog modem. 
Unlike the analog modem, the NT200R-PLUS allows you to use your phone line for 
simultaneous voice/fax and high-speed communications, eliminating the need for 
dedicated phone lines for voice and data communications. The NT200R-PLUS 
provides reliable high-speed data communication in the harshest operating 
environments. It can operate in uncontrolled environments such as remote 
terminals or curb side distribution vaults. Installation is easy ... no tools ... no 
headaches. Simply connect the hardware and apply power. 

 

Designed to operate in the harshest environments the NT200R-PLUS has an 
operating temperature range of -37°C to +74°C, in non-condensing humidity of up 
to 95%, and can be set up at altitudes of up to 10,000 feet. 

 

This manual has been designed to enable you to install your NT200R-PLUS modem 
by following the step-by-step installation procedure. 

 

FEATURES 

Easy to install standalone ADSL modems 
Environmentally hardened for operation in harsh environments 
Auto-sensing full or half-duplex Ethernet 
Auto-sensing 10/100 operation 
Transparent operation 
LED indicators for Power, Ethernet Link & Activity, ADSL Sync 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Summary of Contents for NT 200R-Plus

Page 1: ...NT 200R PLUS ADSL Modem Router User Guide GDI COMMUNICATIONS LLC PO Box 1330 Verdi NV 89439 ...

Page 2: ...pper Inc computer product or component thereof resulting from accident abuse or misapplication of the product and GDI Communications LLC assumes no liability as a consequence of such events under the terms of this Warranty GDI Communications LLC does not warrant the merchantability or fitness of this product for any particular purpose This limited warranty is in lieu of any and all other warrantie...

Page 3: ...TING POWER 8 OPERATION 9 POWER UP 9 FRONT PANEL LED STATUS MONITORS 9 CONFIGURING FOR INTERNET CONNECTION 11 SETTING UP YOUR PC 11 WAN CONFIGURATION 13 LAN CONFIGURATION 14 VPN CONFIGURATION 15 SAVING YOUR CONFIGURATION 16 CUSTOMER SERVICE 17 SERVICE AND UNRESOLVED PROBLEMS 17 APPENDIX A 18 SPECIFICATIONS 18 APPENDIX B 20 INTERFACE PIN ASSIGNMENT 20 3 ...

Page 4: ...shest operating environments It can operate in uncontrolled environments such as remote terminals or curb side distribution vaults Installation is easy no tools no headaches Simply connect the hardware and apply power Designed to operate in the harshest environments the NT200R PLUS has an operating temperature range of 37 C to 74 C in non condensing humidity of up to 95 and can be set up at altitu...

Page 5: ...ting the ADSL Line Interface on page 6 See Figure 4 for the rear panel connector arrangements 2 Connecting the Ethernet interface refer to section titled Connecting the LAN 10 100Base T Ethernet Interface on page 7 3 Connecting the power plug refer to section titled Connecting Power on page 8 NT200R PLUS ADSL Line 4 Ports of Ethernet Access Power Jack ON OFF Switch Figure 1 NT200R PLUS standalone ...

Page 6: ...ce to the DSL ready telephone line Connect a telephone phone cable from the DSL equipped telephone line jack to the jack marked DSL on the rear panel of the modem To function properly the NT200R PLUS must be connected to the telephone line using twisted pair wire between 19 0 9mm and 26 AWG 0 4mm The interface is bipolar making the TIP and RING connection non critical The diagram below shows the p...

Page 7: ...able Ethernet card installed in your computer If your Ethernet card does not auto negotiate you must set it to half duplex Refer to the Ethernet card manufacturer s instructions for installing and configuring your Ethernet card Connecting the LAN 10 100BaseT TX Ethernet Port to a Hub The NT200R PLUS LAN interface is configured as DCE Data Communications Equipment just like a 10 100BaseT TX network...

Page 8: ...le Power to the NT200R PLUS is connected using the barrel jack on the rear panel No configuration is necessary for the power supply AC power supplied must meet the following requirements 12DC 1A The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions 8 ...

Page 9: ...nnecting Power to verify that the unit is connected to the appropriate power source FRONT PANEL LED STATUS MONITORS The NT200R PLUS features six front panel LEDs that monitor power the ADSL Connection and the Ethernet connections Figure 5 shows the front panel location of these displays Table 1 describes the LED functions NT200R PLUS Power ADSL Link PWR Ethernet LAN Figure 5 NT200R PLUS Front pane...

Page 10: ... Green Power ON and Waiting for carrier detect signal 1 flash sec Moderate Flashing Green Power ON and attempting synchronization 2 flashes sec Steady green ON to indicate that the ADSL link is established Steady Green Ethernet link has been established Flashing Green Transmit or Receive Activity No Light No Ethernet link established Table 1 Front panel LED description 10 ...

Page 11: ...rotocol TCP IP Click on the Properties button The Internet Protocol TCP IP properties dialog box will appear On the General TAB select Obtain an IP address automatically and below that select Obtain DNS server address automatically Click on the OK button and proceed to configure your router Load the Router Management software Double on the ecmanagement exe Right click on Management exe file and se...

Page 12: ...Click on Refresh Config button The router information will appear in all the fields in all tabs 12 ...

Page 13: ...ame for your circuit Enable your circuit by selecting YES from the dropdown menu Select the Circuit VPI and VCI The default numbers are typical for most applications Select the Quality of Service QoS for your installation UBR is typical Change Peak Cell Rate as required 0 equals your Line Rate Click on the Save Change button The software will restart A YES NO dialog will appear and it will tell yo...

Page 14: ... you network select DHCP Server If this router will be relaying addresses select DHCP relay agent DHCP Server information This is where the information for the DHCP IP address pool will be established Enter IP address for the first IP client on your network in the IP Range Start box Enter IP address for the last IP client on you network in the IP Range Stop box Enter the IP address of the Gateway ...

Page 15: ...sh Algorithm to be used in this VPN the options are MD5 SHA1 Under Phase 2 Connection Profile Enter the Local IP address of this router This is the network address for this router Enter the Local IP Subnet mask This is the subnet mask for this router Enter the Remote Internal Router IP address this is the Ethernet address for the remote router Enter the Remote IP address This is the Ethernet netwo...

Page 16: ...g on the Save Changes button the dialog boxes below will be displayed If you are sure of the changes you have made click on Yes Click OK The warning screen message below will appear When you are ready for your changes to be applied Click on Tools in the Menu Bar Click on Restart Router The router will restart all changes will be applied 16 ...

Page 17: ...pany name mailing address telephone number RMA number and any special instructions During the first year after the date of purchase all labor and materials will be provided without charge There shall be no warranty for either parts or labor after the expiration of one year from the date of purchase or if in Extreme Copper s sole discretion the product has been deemed to be modified or abused Units...

Page 18: ...m twisted pair wire LED INDICATORS Power Green DSL Sync Green LAN Ethernet Good Link Green Red Amber POWER SUPPLY External AC power cube input 112 VAC 47 to 63Hz 6 Watt 12 0 Output OPERATING ENVIRONMENT TEMPERATURE RANGE 37 C to 74 C HUMIDITY Up to 95 non condensing DIMENSIONS 1 25H x 5 3W x 5 3D in 3 68H x 12 19W x 12 37D cm MOUNTING Standalone metal enclosure 18 ...

Page 19: ...th the manufacturer s instructions it may cause interference to radio and television reception The NT 200 has been tested and found to comply with Class B computing device in accordance with specifications in Subpart B of Part 15 of FCC rules However there is no guarantee that interference will not occur in a particular installation 19 ...

Page 20: ...N ASSIGNMENT LAN ETHERNET 10 100BASET TX INTERFACE RJ 45 UTP STP Pin 1 RX Pin 2 RX Pin 3 TX Pin 6 TX Pins 4 5 7 8 no connection Shield Bat Com STP only ADSL LINE INTERFACE RJ 11 Pin 2 RING Pin 3 TIP Pins 1 4 no connection 20 ...

Page 21: ...Copyright 2011 GDI Communications LLC All Rights Reserved 21 ...

Reviews: