background image

 

 
 
 
CONTACTS AND OFFICES 

HFR UPGRADE MANUAL 
FOR SX-2001/SA-2100(A/T) TO SX-000(A/T)R 
DIGITAL CINEMA SERVER WITH 
INTEGRATED MEDIA BLOCK  

 6 

                                                    May 18, 2016 

 

 

 

 

 
 

CONTACTS AND OFFICES

 

Website:  

www.gdc-tech.com 

   Email: 

[email protected] 

 

24/7 Engineering Support Hotline: 
 

Hong Kong 
(Headquarters) 

 
 
 
 

China (Beijing) 

 

China (Shenzhen)

 

 

Spain (Barcelona)

 

 

Unit 1-7, 20th Floor, 
Kodak House II, 
39 Healthy Street East, 
North Point, Hong Kong 
 
Tel: +852 2507 9555 
 

Rm. 609-618, Office 
Building,20# Xinde Street, 
Xicheng District, Beijing, 
P.R. China 100088 
 
Tel: +86 10 6205 7040 
 

Room A701, 7/F, 
Languang Technology Building, 
No.7 Xinxi Road, North Zone, 
HighTech Park,  Nanshan District,  
Shenzhen, China 
Tel: +86 755 8608 6000 
 

Edificio Mercurio 
Vía Augusta, 59, desp. 
607 
08006 Barcelona, Spain 
 
Tel: +34 93 159 51 75 

 

 
Peru (Lima) 

 

 

 
USA (Los Angeles) 

 
Brazil  
(São Paulo)

 

 

 
Singapore 
 
 
 
 

 
Calle Manuel Miota 170, 
Miraflores Lima 18, Peru 
 
 
Tel: +51 1 340 5146 

 
1016 West Magnolia  
Boulevard Burbank,  
CA 91506, USA 
 
Tel: +1 818 972 4370 /  
       +1 877 743 2872  
       (Toll Free) 
 

 
Rua da Penha, 426, 
4º andar, conjunto 43, 
CEP 18010-001 - 
Sorocaba/SP 

– Brasil 

Tel: +55 15 33269301 

 
10 Ubi Crescent,  
Ubi Tech Park, 
Lobby B, #06-25 
Singapore 408564 
Tel: +65 6222 1082 

North America     

+1 877 743 2872 (Toll Free)    

Latin America   

+52 55 8851 1198 

Europe 

+34 928 912 295    

China 

+86 400 886 0996  (Toll Free) 

North Asia     

+852 3520 0920 (Toll Free)          

India 

+91 022 4044 0500 

South East Asia 

+65 6100 4328 

Australia/ New 
Zealand 

+61 407 040 744 

 

 

 

 

Summary of Contents for SA-2100A

Page 1: ...HFR UPGRADE MANUAL FOR SX 2001 SA 2100 A T TO SX 2000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK SMS version 9 0 May 18 2016...

Page 2: ...tall the DCI Card 11 3 5 Un install the GPI O Card 12 3 6 Un install the Sound Card 13 3 7 Remove the Vented Back Plate 13 3 8 Install the Back Plate for SX 2000 Model Configuration 14 4 INSTALLING TH...

Page 3: ...ctor 27 9 3 Christie Series 2 Projector 29 9 3 1 Christie Series 2 Projector 3D Settings 32 10 IMB 3D MACRO SETTINGS CHANGES 33 10 1 Barco Series 2 Projector 33 10 2 NEC Series 2 Projector 33 10 3 Chr...

Page 4: ...reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiv...

Page 5: ...l breach by Licensee 6 Licensee agrees to return to Licensor or to destroy all copies of the Software upon termination of the License 7 This License Agreement is the entire and exclusive agreement bet...

Page 6: ...Zone HighTech Park Nanshan District Shenzhen China Tel 86 755 8608 6000 Edificio Mercurio V a Augusta 59 desp 607 08006 Barcelona Spain Tel 34 93 159 51 75 Peru Lima USA Los Angeles Brazil S o Paulo...

Page 7: ...Grogol Petamburan Jakarta Barat 11440 Indonesia Tel 62 21 2920 4691 3F Kyobashi Chuo Bldg 1 14 7 Kyobashi Chuo ku Tokyo 104 0031 Japan Tel 81 3 5524 2607 Office No B 207 208 Everest Chamber Andheri Ku...

Page 8: ...ges of 3 5 upgrade sets 13 Return Item Checklist Subject to actual configuration Please specify with our sales representatives Note RJ45 network cables should be of good quality CAT6 cables to guarant...

Page 9: ...MA SERVER WITH INTEGRATED MEDIA BLOCK 3 REMOVING THE EXISTING COMPONENTS OF THE SX 2001 SA 2100 Mounting Holder DCI GPI O Card Sound Card 3 1 Detach the mounting holder 1 Unscrew the mounting holder a...

Page 10: ...0 A T TO SX 000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 10 May 18 2016 3 2 Cut the Cable Holder plastic 1 Refer to the circled area in Figure 3 kindly cut the cable holder plastic tie...

Page 11: ...TO SX 000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 3 3 Detach the Flat Cable 1 Detach the pin head of Flat cable from the DCI side as indicated in Figure 4 3 4 Un install the DCI Card...

Page 12: ...t the DCI card from the PCI slot and set aside 3 Kindly remove the power pin head red circle indicated in Figure 6 which is connected to the fan on the DCI card to the pin head of the power supply 3 5...

Page 13: ...DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 3 6 Un install the Sound Card 1 Same procedure remove the sound card by un securing the screw as indicated in Figure 8 3 7 Remove the Vented Back Pla...

Page 14: ...TO SX 000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 14 May 18 2016 3 8 Install the Back Plate for SX 2000 Model Configuration Figure 10 Install the back plate 1 Install the back plate f...

Page 15: ...itor Password wiije67 md5sum 2fc13509c8c172be25f24c73dd717e0e upgrade SX2000AR 9x networkcard 20121109 tgz enc Upgrade password 20121109 3 Boot up the server and apply upgrade SX2000AR 9x networkcard...

Page 16: ...are reserved for IMB 6 Server eth1 is directly connected to IMB Ethernet 2 7 Server eth0 is connected to projector Ethernet port either directly or via a switch 8 Server eth2 from the installed gigabi...

Page 17: ...14 SX 2000 rear panel with cables attached 5 1 Ethernet Connections 1 Make sure the IMB is powered up inside the projector correctly 2 SX 2000 A T R eth0 IP must NOT be 192 168 1 X recommend it to be...

Page 18: ...4 to connect the network cable to the IMB on the projector and to the SX 2000 A T R server If the projector does not have the GDC IMB installed follow the steps below to install the IMB into the proj...

Page 19: ...check the figures below to ensure proper placement of the IMB Figure 17 shows an interface board with SMPTE 292 inputs connected to a Barco projector This board must be removed in order to install the...

Page 20: ...on before installing the IMB Figure 19 IMB placement on NEC projectors Please refer to the projector manuals for more details on preparing the projector for IMB installation 6 3 Inserting IMB to the P...

Page 21: ...server CAT 5E network cable to connect the network between the projector and the server The projector and server can also be connected through a network switch Network cable for connecting the IMB in...

Page 22: ...rtificate After upgrading SX 2001 SA 2100 A T to SX 2000 A T R for HFR IMB the server sha256 certificate will be updated so new KDMs must be issued with the updated sha256 certificate Previous KDMs be...

Page 23: ...TO SX 000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 8 2 Apply Upgrade Package 1 1 Figure 23 Upgrading from an USB disk 1 Install from SMS Configuration Assistance USB Disk 2 Figure 24 S...

Page 24: ...A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 24 May 18 2016 3 Figure 25 Upgrade completed 3 The upgrade will take under one minute then a window Upgrade completed Click OK to reboot will p...

Page 25: ...incremental upgrade i e without checking that the system is able to playback a DCP from the server the upgrade may fail and the IMB LED displays RED color after reboot When this happens only a GDC aut...

Page 26: ...2001 SA 2100 A T TO SX 000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 26 May 18 2016 4 Figure 27 Press password to log in SMS 4 The above screen will show up after rebooting and requires...

Page 27: ...on the server must be cleared before the IMB can be used for playback In order to use the IMB for content playback the INPUT source of the projector macros must be set to IMB See Figure 28 Figure 28 I...

Page 28: ...ERVER WITH INTEGRATED MEDIA BLOCK 28 May 18 2016 3 Figure 29 Service mode on NEC Digital Cinema Communicator 4 Select Setup Option Slot on the Digital Cinema Communicator and select IMB for Slot A in...

Page 29: ...xecute 7 Clear the Service Door Marriage Tamper on the server In order to use the IMB for content playback the INPUT source of the projector macros must be set to IMB 9 3 Christie Series 2 Projector W...

Page 30: ...rojector is secure before proceeding Click the Next button to proceed to the Arming window Figure 32 Marriage checklist c Arm the marriage In the Arming window click the Arm Marriage button refer to F...

Page 31: ...IA BLOCK Figure 33 Arm Marriage and Marriage countdown d The Finish window states the success of the marriage Click the Finish button to return to the Main panel 2 Clear the Service Door Marriage Tamp...

Page 32: ...e projectors 9 3 1 Christie Series 2 Projector 3D Settings The 3D macros for Christie Series 2 projectors should be configured with the following settings for 3D Input Control see Figure 35 3D Sync In...

Page 33: ...ll not function properly unless these changes are made Software version 9 0 enables IMB 3D output in 4 4 4 format This can be enabled on the SMS configuration page by selecting SMS Configuration CineC...

Page 34: ...dditional configuration is required for the projector 11 AFTER THE UPGRADE 2 Figure 37 Server eth1 1 After the upgrade is completed powercycle both the server and projector with IMB 2 IMB marriage and...

Page 35: ...oftware Upgrade vncviewer projectorIP 43752 to see the SOM User Interface 3 Apply the SOM software upgrade package e g named as upgrade SOM step3 build56 20120911 tgz enc on SOM not server in the same...

Page 36: ...MEDIA BLOCK 36 May 18 2016 13 PREPARING FOR PLAYBACK 1 Figure 38 Turn off the server 1 Click server SMS Shutdown Shutdown to turn off the server After the server is turned off the IMB SOM on projector...

Page 37: ...R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 5 Figure 39 Configure Projector 1 TI IP 5 Configure Projector 1 TI IP on server SMS Configuration Cinecanvas 6 Figure 40 SMS Interface 6 Once SM con...

Page 38: ...A T TO SX 000 A T R DIGITAL CINEMA SERVER WITH INTEGRATED MEDIA BLOCK 38 May 18 2016 14 PROJECTOR SETTING FOR MPEG2 PLAYBACK ON SOM 1 Figure 41 Projector setting Input format 1 Input format is 422 12...

Page 39: ...CAUTION Please use Server SMS Shutdown Shutdown to turn off the server and IMB After the server and IMB are turned off the projector may indicate communication lost to the IMB the projector must be r...

Page 40: ...5524 3607 Spain Barcelona Edificio Mercurio India Mumbai V a Augusta 59 desp 607 Office No B 207 208 Everest Chamber 08006 Barcelona Spain Andheri Kurla Road Marol Andheri East Tel 34 93 159 51 75 Mum...