background image

6. Setting up the Ethernet gateway for use with iG-HUB Express

iG-HUB Express (PC Software) Setup

Visit http://www.G-HUB.com/support/downloads/ to download and install the iG-HUB 
Express software. 

 

•  Launch the iG-HUB Express installer and follow the on-screen instructions. 

•  Launch the iG-HUB Express program. 

 
 
 
 

•  Activate the Express software with the code you received when purchasing. 

 

 

 
 
 
 
 
 
 
 

•  Add the gateway(s) and wireless sensors to the software. 

 

Contains FCC ID: ZTL-RFSC1 

                

 

and IC: 9794A-RFSC1

This device complies with Part 15 of the 

FCC Rules. Operation is subject to the 

following two conditions:

 

(1) this device may not cause harmful 

      interference and 

(2) this device must accept any interference 

      received, including interference that may 

      cause undesired operation. 

ID: ######

Code: XXXXXX

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

•  Verify that the gateway was added successfully by checking the Gateways list. 

 

 

 
 
 

PAGE 16

PAGE 17

Ethernet Gateway MIB tree with a short description of each field:

EGW Data

Description

*GW Section

Gateway Section

*GW Serial

Gateway Serial ID

*Version

Gateway Firmware Version

*WD Count

Wireless Device Count

*WNetSection

Wireless Network Seciont

*WD Entry

Wireless Device Entry

*Index

Index Number

*Serial

Wireless Device Serial ID

*Type

Device Type (eg temp, water, motion sensor, etc)

*Age

Number of seconds since last data recording

*Active

Indicates if the wireless device is reporting in as expected

*Alarming

Indicates if the wireless device has detected data that is urgent or 

breaches a threshold

*Voltage

Battery voltage recorded at the time of data reading

*RFSignal

Signal Strength recorded on data reading delivery

*Data1

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data2

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data3

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data4

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data5

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data6

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data7

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

*Data8

Data recorded by wireless device (eg temperature, water de-

tected, motion detected, etc)

Summary of Contents for G-HUB

Page 1: ...the connection is snug but do not overtighten Plug an Ethernet cable with internet connectivity into the gateway Plug the power supply into a power outlet then connect to the gateway Once all three l...

Page 2: ...2 Indicates the Ethernet has internet connectivity and can reach the online moni toring system A green light indicates ready and working a red light indicates there is a problem A flashing green ligh...

Page 3: ...e immediate response from the sensor power cycle the sensor by removing then re inserting the battery Notes If the sensor status indicator does not change reset the sensor by removing the battery Wait...

Page 4: ...sensor detail information To change the date range click inside the date box 2 History and Chart Views Clicking on the History or Chart tabs within the sensor detail panel allows you to view the sens...

Page 5: ...ws the user to set notifications based on advanced rules such as comparing past data points with the current one to determine if a notification should be sent Existing Notifications Use notifications...

Page 6: ...n your network you will also see a Devices to Notify tab This will allow the notification to interact with these types of devices Select a device from the list on the left and click the arrow button t...

Page 7: ...tive and Save The default port is 3500 but can be edited PAGE 12 PAGE 13 5 Advanced Settings and Interfacing with the G HUB Ethernet Gateway Through iG HUB 1 Ethernet Gateway Edit Screen When you log...

Page 8: ...erface Active and Save The MODBUS TCP Interface will store all data values in 16 bit registers The registers and their data fields are mapped below Field Description Register Data Address GATEWAY Gate...

Page 9: ...Device Count WNetSection Wireless Network Seciont WD Entry Wireless Device Entry Index Index Number Serial Wireless Device Serial ID Type Device Type eg temp water motion sensor etc Age Number of sec...

Page 10: ...the PC firewall does not prohibit an inbound connection Plug power cable into the Ethernet gateway Plug in the power cable While the device is booting press and hold the Reset Button on the back of th...

Page 11: ...ipt of the product G HUB reserves the right to repair or replace products at its own and complete discretion Customer must obtain from G HUB a Return Material Authorization Number RMA prior to returni...

Page 12: ...her antenna or transmitter PAGE 22 PAGE 23 Canada IC English Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved fo...

Page 13: ...ons on how to use your G HUB Wireless Sensors or the iG HUB Online System please visit us on the web at http www G HUB com support Global Design Corporation Inc 67 East Park Place Suite 750 Morristown...

Reviews: