background image

- 16 -  

February 21

st

, 2023

 

USER MANUAL FOR AIB-2000 IO (INPUT-OUTPUT) BOX  

 

9. AIB-2000 CONNECTIONS 

 

 

 

 

 

 

  7.1 Input 

Eight RCA connectors are provided for analog input from 7.1. signal source. 7.1 input can be 
routed to 7.1. output by selecting the 

7.1. ANALOG

 button on the front. 

 

  Rear NON-SYNC IN 

Rear left and right RCA NON-SYNC inputs provide the user with the possibility of connecting an 
additional stereo device with line-level outputs. 

Rear XLR NON-SYNC input can be routed to 7.1. output by selecting the 

NS RCA

 button at the 

SELECTOR

 section. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AIB-2000

Page 1: ...USER MANUAL FOR AIB 2000 IO INPUT OUTPUT BOX February 21st 2023...

Page 2: ...Shipping Damage 12 8 3 Packing Material 12 9 AIB 2000 CONNECTIONS 13 9 1 Installation 13 9 2 AC Mains Supply 13 9 3 Routing Diagram 13 9 4 Front Panel 14 Front NON SYNC IN 14 MIC INPUT 14 SELECTOR 14...

Page 3: ...2 February 21st 2023 USER MANUAL FOR AIB 2000 IO INPUT OUTPUT BOX TABLE OF CONTENTS 11 4 2 1 Config Signal routing 21 11 4 2 2 Config IP config 23 11 4 2 3 Config Misc config 24 Sensors Info 25...

Page 4: ...3 February 21st 2023 USER MANUAL FOR AIB 2000 IO INPUT OUTPUT BOX TABLE OF CONTENTS CONTACTS AND OFFICES Website Contact Us Worldwide Offices 24 7 Support...

Page 5: ...4 February 21st 2023 USER MANUAL FOR AIB 2000 IO INPUT OUTPUT BOX 1 DIMENSIONS 1 DIMENSIONS Figure 1 Dimensions of AIB 2000 Unit...

Page 6: ...r Analog unbalanced 7 1 input 8 x RCA Analog H I output 1 x RCA Analog V I output 1 x RCA Monitoring output L C R summed 1 x RCA Analog balanced output 8 x 3 pin Phoenix AES3 input 1 x RJ 45 Ethernet...

Page 7: ...0 Hz switch E MIC IN Gain knob F MIC IN switch G AES3 selector H 7 1 Analog selector I NON SYNC Rear RCA selector J NON SYNC Front XLR selector K Mains switch L C14 Mains socket M Serial number space...

Page 8: ...7 February 21st 2023 USER MANUAL FOR AIB 2000 IO INPUT OUTPUT BOX 4 ROUTING DIAGRAM 4 ROUTING DIAGRAM Figure 3 Routing Diagram for AIB 2000...

Page 9: ...21st 2023 USER MANUAL FOR AIB 2000 IO INPUT OUTPUT BOX 5 ETHERNET AES3 ANALOG OUT CONNECTION 5 ETHERNET AES3 ANALOG OUT CONNECTION Analog outputs balanced lines Analog outputs unbalanced lines ETH por...

Page 10: ...t WEEE WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO COMPLETELY DISCONNECT...

Page 11: ...only accessories specified by the manufacturer 13 Unplug this unit during lightning storms or when unused for long periods 14 Refer all servicing to qualified service personnel Servicing is required w...

Page 12: ...ts are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed an...

Page 13: ...ormation on how to interface the AIB 2000 with the GDC SR 1000 IMB and the cinema sound system 8 2 Unpacking and Checking for Shipping Damage Your AIB 2000 has been completely tested and inspected bef...

Page 14: ...AC Mains Supply The AC Main connection is made via the IEC C13 connector The DC series amplifiers have an automatic power factor correction system PFC for a perfect mains network interface The PFC min...

Page 15: ...XLR button at the SELECTOR section MIC INPUT Microphone input with preamplifier is provided for the convenience of making announcements including emergency messages GAIN knob controls the gain of the...

Page 16: ...or the correct wiring of the AES3 RJ 45 socket ETH Input Ethernet RJ 45 connector provides IP connection It can be used to access built in web interface to set up the AIB 2000 or receive the control a...

Page 17: ...nal source 7 1 input can be routed to 7 1 output by selecting the 7 1 ANALOG button on the front Rear NON SYNC IN Rear left and right RCA NON SYNC inputs provide the user with the possibility of conne...

Page 18: ...n is implemented through an Ethernet connection Control allows switching of the input source from AES3 7 1 ANALOG and NON SYNC turning ON OFF MIC setting MIC output to CENTER SIDE SURROUND channels Th...

Page 19: ...Default factory network settings for AIB 2000 are as follows IP Address 192 168 0 8 Network mask 255 255 255 0 Gateway 192 168 0 1 Username Please contact GDC for the username and password of the web...

Page 20: ...e network mask Open a web browser and enter the IP of the AIB 2000 in the Address bar Enter the login credentials and click on the Sign In button Figure 8 Accessing the Web Interface 11 4 About the AI...

Page 21: ...switch the microphone ON and OFF 2 AES3 Allows the user to switch to AES input 3 7 1 ANALOG Allows the user to switch to 7 1 analog input 4 NON SYNC RCA Allows the user to switch to Rear NON SYNC RCA...

Page 22: ...g Signal routing The Signal routing tab allows to choose the default set at startup 7 1 Analog input and the output for the microphone input Figure 10 Signal routing 1 Sr No Name Function Description...

Page 23: ...2000 WEB INTERFACE Figure 11 Signal routing 2 2 Microphone channels Allows the user to choose the output for the microphone input from Center screen channel or Surround channels 3 Save Cancel Click o...

Page 24: ...k settings for the AIB 2000 Figure 12 IP config Sr No Name Function Description 1 MAC Displays the MAC address of the AIB 2000 device 2 Static IP Allows the user to change the IP address of the AIB 20...

Page 25: ...user name and password used to access the device Figure 13 Misc config Sr No Name Function Description 1 Device name Allows the user to set a custom device name for the AIB 2000 for easier navigation...

Page 26: ...Info Click on the icon at the top right corner of the web interface to access the sensor information which can be used for remote monitoring of the AIB 2000 These sensors provide information regarding...

Page 27: ...ed Copyright 2023 GDC Technology Limited All rights reserved All trademarks listed in this manual are properties of their respective owners Speci cations are subject to change without notice due to on...