Function 

Description 

Display screen

Audible 

alarm

Action

Battery

monitoring 

When the battery 

power is becoming low.

‘ CHANGE 

BATTERY’

Yes

Change the battery at the earliest 

convenient time but not later than 

five hours after the low battery 

alarm.
Caution: If the battery power is 

too low the ECOLITE

®

 4000 will 

not function at all.

6.4 AFTER USE

6.4.1 SWITCHING OFF THE DEVICE
Switching off manually

The ECOlite

®

 4000 can be switched off when treatment is no longer required or it is necessary to 

interrupt it, by pressing the ON/OFF button on the front of the unit for approximately 3 seconds.

• 

An audible signal will confirm the unit is switched off. 

• 

The current settings will be stored automatically.

Switching off automatically

If the device is switched on or being used, but no breathing has been detected by the ECOlite

®

 4000 

for one minute:

• 

The display shows CHECK CANNULA and an audible signal sounds. 

• 

After another 30 seconds without any corrective action (inhalation) the unit will switch off. 

• 

The current settings will be stored automatically.

After ending a therapy close the valve on the supply in order to avoid wasting oxygen.

6.4.2 DISCONNECTING THE DEVICE
Before disconnecting the ECOlite

®

 4000 from the gas source:

• 

Close the oxygen supply from the cylinder (reservoir), disconnect the connector of the spiral hose 

from the device and take off the nasal cannula.

• 

Disconnect the spiral hose from the oxygen source.

• 

Remove the batteries from the device*.

• 

Visually check the device or accessories for contamination and put it preferably into the shipping 

container.

It is necessary to take out the batteries if the ECOlite

® 

4000 is not in use for some time.

ACCESSORIES

• 

Standard accessories include:

7

.

• 

Cannula 

• 

Batteries 

Note: For current spare part list, please contact GCE. 

• 

A nasal cannula designed for single use is supplied in 

addition to the ECOlite

®

 4000 device  as a standard. Its 

design (being made up of segments) prevents a possible 

injury of the patient or his/her choking.

When the cannula is used more times, there is a danger of infection.
This product contains the phthalates. GCE s.r.o. dissuade to use this product for children, 

nursing mothers and pregnant women because these matters are dangerous.

• 

Additional accessories (they are not part of the delivery) comprises a portable belt bag, a 

portable rucksack for the complete assembly and a cart for transporting the assembly. For more 

detailed information, contact the supplier.

Summary of Contents for ECOlite4000

Page 1: ...EN Page 1 12 ECOlite 4000 GAS SAVER INSTRUCTION FOR USE...

Page 2: ...om the oxygen The dosage and timing of oxygen delivery is controlled by a microprocessor in accordance with the chosen setting Dosage per breath is independent of breathing rate therefore additional o...

Page 3: ...TIONS At atmospheric pressure up to 60 oxygen is harmless 100 oxygen produces a cough after 6 hours and increasing breathlessness after 25 hours PERSONNEL INSTRUCTIONS AND TRAINING According to Medica...

Page 4: ...function from national standards In the event of any problem with connection please contact the distributor the manufacturer Display screen ON OFF button Oxygen inlet Outlet into cannula Control butt...

Page 5: ...clean If the unit is being used with an oxygen supply source with adjustable fl ow rates set the flow rate on the supply source to 4 litres per minute or to the closest setting above Check the cylinde...

Page 6: ...s the button and hold it down Afterwards press the ON OFF button and also hold it down A PRESS KEY sign will appear Press the two buttons marked and simultaneously a LANGUAGE sign will appear Using th...

Page 7: ...ngly Activate the alarm by not breathing in the cannula After approx 1 minute the alarm should set off both by sound and an alert on the display If there is an abnormal sound noise gas leakage or any...

Page 8: ...void wasting oxygen 6 4 2 DISCONNECTING THE DEVICE Before disconnecting the ECOlite 4000 from the gas source Close the oxygen supply from the cylinder reservoir disconnect the connector of the spiral...

Page 9: ...At the end of the product s life time 10 years at most the ECOlite 4000 device must be withdrawn from service To prevent reuse the owner shall make the ECOlite 4000 impossible to use or return it to...

Page 10: ...c Area EEA This mark on the product indicates compliance with Directive 93 42 EEC relating to medical devices Class IIa Functional performance Sensitivity 0 13 cm of H2O Setting Manual automatic Trigg...

Page 11: ...eter Use by Outlet parameter Take back equipment for recycling Do not dispose equipment into unsorted municipal waste WARRANTY The Standard Warranty period is two years from date of receipt by the GCE...

Page 12: ...Asia The company operates 15 subsidiaries around the world and employs more than 850 people GCE Group includes four business areas Cutting Welding Process Applications Medical and High Purity Today s...

Reviews: