background image

UK

26

TOP EVO

27

TOP EVO

UK

OPERATOR

Operating frequency (%Fu) at 20°C
Electric motor

Capacitor

Maximum thrust

Hydraulic slowdown

Rod maximum stroke

Operating temperature

Leaf maximum lenght
Hydraulic lock granted for leaf 

maximum lenght

Power absorbed

Protection degree

Thrust adjustment

Rod speed

Hydraulic oil

Thermal protection

Formula to calculate the operation 

frequency

TOP 391E

TOP 391ER

[ ]

55% 

2a

230 Vac 1450 rpm

max 190 W

10 

μF

IP65

hydraulic

GBD PH-03

[ ]

4.5 m 

2c

2.0 m

100°C

from -20°C to +60°C

3000 N

20 mm/s

yes

265 mm

4500 N

10 mm/s

no

290 mm

TOP 391ER/S

A = Opening time

C = Closing time

P = Overall pause time

A+C+P = Time between two 

             openings

   

 

 

%Fu =

x 100

A + C

A + C + P

OPERATOR

Operating frequency (%Fu) at 20°C
Electric motor

Capacitor

Maximum thrust

Hydraulic slowdown

Rod maximum stroke

Operating temperature

Leaf maximum lenght
Hydraulic lock granted for leaf 

maximum lenght

Power absorbed

Protection degree

Thrust adjustment

Rod speed

Hydraulic oil

Thermal protection

Formula to calculate the operation 

frequency

TOP 441E

TOP 441ER

[ ]

55% 

2a

230 Vac 1450 rpm

max 190 W

10 

μF

IP65

hydraulic

GBD PH-03

[ ]

6 m 

2c

2.0 m

100°C

from -20°C to +60°C

3000 N

20 mm/s

yes

425 mm

4500 N

10 mm/s

no

440 mm

TOP 441ER/S

A = Opening time

C = Closing time

P = Overall pause time

A+C+P = Time between two 

             openings

   

 

 

%Fu =

x 100

A + C

A + C + P

2

TOP 441E  -  441ER  -  441ER/S 

 - TECHNICAL DATA

2

TOP 391E  -  391ER  -  391ER/S 

 - TECHNICAL DATA

Summary of Contents for TOP EVO TOP 291E

Page 1: ...TOP EVO TOP 291E R S TOP 391E R S TOP 441E R S UK Linear hydraulic operator INSTRUCTIONS FOR INSTALLATION...

Page 2: ...17 18 19 20 21 22 23 24 30 40 50 60 70 80 90 100 TOP 391E TOP 441E R S Time h Fu 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 20 30 40 50 60 70 80 90 TOP291E R S Time h 9 2 5 3 4...

Page 3: ...Leaf weight Kg Leaf lenght m 291E R S 391E R S 441E R S 100 200 300 400 500 600 0 1 2 3 4 5 6 TOP391E TOP391ER TOP391ER S TOP291E TOP291ER TOP291ER S TOP441E TOP441ER TOP441ER S 825 1250 65x65 1265 8...

Page 4: ...885 95 245 TOP 391E 90 130 130 950 100 260 110 110 120 950 95 260 TOP 391E TOP 391ER ER S 90 125 125 940 100 250 F 80 100 E 55 65 TOP 391ER ER S 105 110 115 940 95 250 205 1243 TOP 441E 90 205 125 410...

Page 5: ...5 TOP EVO 100 120 B A 100 150 150 150 B A 20 mm 5 6 7...

Page 6: ...M OPENING COM CLOSING YELLOW GREEN BLACK GREY BROWN BROWN GREY BLACK YELLOW GREEN 8 9 6 TOP EVO...

Page 7: ...7 TOP EVO 1 2 3 5 2 3 4 10 11...

Page 8: ...1 PRESSURE ADJUST OPEN CLOSE 2 3 4 1 3 3 4 12 13 8 TOP EVO...

Page 9: ...9 TOP EVO 3 4 5 6 2 1 5 3 4 7 7 4 3 1 5 2 6 14a 14b...

Page 10: ...e the technical data without prior notice in relation to product development READ CAREFULLY THESE INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION Thank you for choosing GI BI DI DISPOSAL GI BI DI adv...

Page 11: ...llation in compliance with the regulations in force Maintenance must be carried out by qualified personnel Before carrying out any cleaning or maintenance operation disconnect the control unit from th...

Page 12: ...to the electric system regulations and other national regulations in force Keeps the mains power connection clearly separated from service connections photocells sensitive edge control units etc The...

Page 13: ...OPERATOR Operating frequency Fu at 20 C Electric motor Capacitor Maximum thrust Hydraulic slowdown Rod maximum stroke Operating temperature Leaf maximum lenght Hydraulic lock granted for leaf maximum...

Page 14: ...ion degree Thrust adjustment Rod speed Hydraulic oil Thermal protection Formula to calculate the operation frequency TOP 391E TOP 391ER 55 2a 230 Vac 1450 rpm max 190 W 10 F IP65 hydraulic GBD PH 03 4...

Page 15: ...tion degree Thrust adjustment Rod speed Hydraulic oil Thermal protection Formula to calculate the operation frequency TOP 441E TOP 441ER 55 2a 230 Vac 1450 rpm max 190 W 10 F IP65 hydraulic GBD PH 03...

Page 16: ...pedestrians they are not allowed to pass through If the installation presents some unsafety details stop the work and contact your dealer Check that the gate structure is strong enough In any case the...

Page 17: ...ovement of the leaf the tractive thrust force and the movement speed vary during the manoeuvre If the leaf is very thick with consequent difficulty in respecting the dimension F it is possible to incr...

Page 18: ...tinthepointpreviouslymarkedatpoint1 checkthelevellingoftheoperatorwithaspiritlevel andmarktheexactfixingpointofthefrontbracket 5 6 10 Remove the operator from the rear bracket 11 Remove the front brac...

Page 19: ...lves and clockwise with a screwdriver 13 in order to decrease the thrust turn the valves anti clockwise In detail The valve 13 adjusts the OPENING thrust The valve 13 adjusts the CLOSING thrust WARNIN...

Page 20: ...Machinery Directive 2006 42 CE Carry out periodic checks on the gate with particular attention to Check the hinges Check the correct operation of safety devices Unlock the operator and verify there i...

Page 21: ...6 A2 2006 A13 2008 A14 2010 A15 2011 EN60335 2 103 2003 A11 2009 ThepartsoftheproductwhicharesubjecttothefollowingstandardscomplyWwiththem EN 13241 1 2003 A1 2011 EN 12445 2002 EN 12453 2002 EN 12978...

Page 22: ...58 TOP EVO NOTE NOTES NOTES NOTAS...

Page 23: ...59 TOP EVO NOTE NOTES NOTES NOTAS...

Page 24: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC1040 08 2022 Re...

Reviews: