48
ENTRA
EB
•
Press
“
ENT
”
until the segment of the display start rotating, release
“
ENT
”
.
•
Display shows
“
St
”, control board is now waiting for
10 seconds and then start the self-learning procedure.
NOTE:
ENTRA EB does NOT need any mechanical stopper, but in this operation, during LP procedure, give
a physical limit to the door depending on the desired angle you need.
11.
Operator starts an opening and closing cycle to memorize the dimensional parameter, when completed the
door will go in closed position and display
will show “
CL
”
fix.
12.
Operator is now ready to work and push button ENTER could be used to give an opening command to the
door