42
ENTRA
EB
door remains closed and none external peripheral can be
detected (including multi-logic selectors).
Signal must be short-circuited with COM if no devices are
connected.
17-18
--
Power supply
15Vdc
–
12W Max*
Power supply output for sensor or other opening devices
19-20
NA Start 2
Opening signal. External devices to open the door can be
connected. The closing of this signal command the opening
of the doors. This signal is monitored both in logic 2 Radar
both in logic 1 Radar
20-21
NA Start 1
Opening signal. External devices to open the door can be
connected. The closing of this signal command the opening
of the doors. This signal is monitored only in logic 2 Radar.
22-23
--
Lock
Output for power supply of electric lock 12Vdc o 24Vdc Max
500mA.
ATTENTION!! set according dedicated paragraph
24-27-29
NA Connector of the
selector switch
Wiring basic/advanced selector.
25-26-28
NA Connector of the
selector switches
Predisposition for selector wiring
NON-AVAILABLE
*Total power available to be divided on all the power outputs.