F2
05
MOTOR 1 DECELERATION
F5
10
MOTOR 2 FORCE
F6
05
MOTOR 2 DECELERATION
BA230
UK
H2
E2
• Parameters type H:
• Parameters type E:
H1
E1
25
Y
MOTOR 1 OPENING TIME
PHOTOCELL 1 ENABLED
25
Y
MOTOR 1 CLOSING TIME
PHOTOCELL 2 ENABLED
H3
E3
20
Y
MOTOR 1 DECELERATION TIME
SAFETY DEVICE (EDGE) ENABLED
H4
25
MOTOR 2 OPENING TIME
H5
25
MOTOR 2 CLOSING TIME
H7
H6
20
MOTOR 2 DECELERATION TIME
5
LEAF 2 PHASE SHIFT IN OPENING
H8
5
LEAF 1 PHASE SHIFT IN CLOSING
H9
5
PAUSE TIME
H10
5
PEDESTRIAN OPENING TIME
H12
H11
5
PEDESTRIAN PAUSE TIME
0000
NUMBER OF CYCLES
H13
H15
0000
0000
xxxx
INSTALLER CODE
NUMBER OF CYCLES DONE
H14
SOFTWARE VERSION (format: R__xx)
Before powering the control unit, run the following tests:
1- Check the electrical connections: improper connection may be harmful to both the control unit and the
operator.
2- Check proper position of the limit switches.
POWER THE DEVICE
3- Check that the red LEDs of the normally closed contacts are on and the green LEDs of the normally open
contacts are off
4- Check that the writing SAF does not appear on the LCD (intercepted or faulty edge).
5- Check that the relative LEDs turn off when limit switches work.
6- Check that the relative LED turns off when the photocells ray is intercepted.
7- Check that the relative LED turns off when the safety devices work.
8- Check that the motors are locked and ready to work with the “GATE COMPLETELY CLOSED”.
9- Remove possible obstacles in the operating area of the gate, then give the command START. At the first
command, the equipment starts opening, then check that the motion direction is correct. If not invert the wires
in the terminals M1 and/or M2.
FINAL CHECKS AND TESTING
41