6.0 ADJUSTMENTS
6.4 Main PCB (PCB1) Calibration Procedure
15. Reconnect the thermal sensor to the Main PCB.
16. Turn Laminator on.
17. Place the beaded thermocouple in the center of the nip rollers (or infrared temperature sensor
pointed right at the nip). Adjust SV2 until the ready light illuminates and the nip temperature is
290
°
F. Do not let the temperature exceed 310
°
F (this could cause the rollers to blister).
18. When the unit is heating, monitor the Amp Probe for meter deflection. The Amp Probe should
deflect to indicate that Laminator is heating, and zero out once the unit has gone to ready.
19. The temperature can be fine tuned while the Laminator is hot by adjusting SV2. Turn SV2
clockwise to decrease heat, and counter clockwise to increase heat. Adjust SV2 in small
increments, and then wait at least 5 minutes for the heat to stabilize. Check temperature with
infrared temperature sensor or beaded thermocouple.
20. Your Main PCB is now calibrated. Remove Amp Probe, and replace left side cover.
6-4
Summary of Contents for Ultima 65
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...4 1 ...
Page 10: ...4 2 ...
Page 11: ...4 3 ...
Page 12: ...4 4 ...
Page 13: ...4 5 ...
Page 14: ...4 6 ...
Page 15: ...4 7 ...
Page 16: ...4 8 ...
Page 17: ...4 9 ...
Page 18: ...4 10 ...
Page 25: ...ULTIMA 65 ELECTRICAL WIRE SCHEMATIC 120VAC 5 7 ...
Page 26: ......
Page 27: ...5 8 ...
Page 38: ...8 1 1 COVER ASSY AND FILM ROLL SUPPORT 8 1 ...
Page 40: ...8 1 2 CASE AND TRAY ASSEMBLY 8 3 ...
Page 42: ...8 1 3 LEFT SIDE ASSEMBLY 8 5 ...
Page 44: ...8 1 4 RIGHT SIDE ASSEMBLY 8 7 ...
Page 46: ...8 1 5 FRAME ASSEMBLY 8 9 ...
Page 48: ...8 1 6 ROLLER ASSEMBLY 8 11 ...