10.1.2 'GV1' Diagnostic LED
Refer to this table for codes displayed by the 'GV1' Diagnostic LED indicator.
Mode
Status/Description
F
la
s
h
in
g
S
te
a
d
y
Pattern - Four fast-flashes
F
la
s
h
1
F
la
s
h
2
F
la
s
h
3
F
la
s
h
4
Standby
Modes
Unit OK/Idle
Green
Unit Disabled/Inhibited
Orange
Unit out of order - Hard Fault
Red
Active
Modes
Unit Busy
Green
Soft Fault - Check Unit (e.g.
Cashbox full)
Red
Sensors Read Low - clean
sensor lenses
Orange
Program
Modes
Note Enable - Programming
Mode
Green - Fast
Note Disable - Programming
Mode
Red - Fast
Primary Calibration -
Programming Mode
Orange - Fast
Note Reject
Codes
Unrecognised Note
Red x 1
OASG* Reject
Red x 2
MASG** Reject
Orange x 2
Returned (note inhibited in
config settings)
Red x 3
Returned (note inhibited by
host)***
Orange x 3
Transport during note
scanning
Red x 4
Transport problem as the
note hits the MASG
Orange x 4
Note entered with excess
skew
Red x 5
More than one note inserted
Red x 6
Error
Codes
Eeprom fault
Red
Red
Green
Green
ST2 Firmware Rev too low
Red
Red
Green
Orange
ST2 not detected
Red
Red
Green
Red
RFI Controller not detected
(for Audit feature)
Red
Red
Orange
Green
ST2 Transport Init Failed
Red
Red
Orange
Orange
ST2 Powerup Timeout
Red
Red
Orange
Red
Cashbox is Missing
Red
Red
Red
Green
Required IFace PCB
Missing
Red
Red
Red
Orange
Queue Overflow Int Com
Red
Orange
Green
Green
Queue Overflow State M
Red
Orange
Green
Red
Queue Overflow Audit
Red
Orange
Green
Orange
Internal Comms Buffer Size
Error
Red
Orange
Orange
Green