6.0 PROGRAMMING GV1 

6.1 Programming 

The GV1 unit has a number of easy-to-use features to facilitate initial programming and simplifying 
in-service updates and maintenance. 
 
The  GV1  unit  can  be  partly  configured  using  the  on-board  controls  or  more  thoroughly  via 
Windows-based  software  packages  (GBA  Talk  &  GV  Talk).    Configuration  changes  can  also  be 
made by downloading a new configuration file from a suitable USB device. 
 
It  is  worthwhile  to  understand  that  the  overall  functionality  of  GV1  is  split  between  the  ST2 
validation module and the GV1 unit itself.  The ST2 validation module is primarily concerned with 
the  currency  settings  &  currency  configuration,  whereas  the  GV1  unit  handles  functional  user 
settings and the settings for interfacing to the host machine. 
 

 

 
 
Given  this  split-functionality,  programming  is  generally  directed  at  the  appropriate  area.    For 
example,  to  make  changes  to  the  currency  set  or  note  set,  the  ST2  validation  module  is  directly 
addressed.   
 
GV1  programming  is  reserved  for  Service  and  Support  technical  staff  and  is  explained  in  the 
comprehensive GV1 Reference Manual 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

GV1 

ST2 

FUNCTIONAL USER SETTINGS 

INTERFACE SETTINGS 

CURRENCY SET 

NOTE SETTINGS 

Summary of Contents for GV1

Page 1: ...ber 2018 GBA GV1 Operation Manual v2 00 Page 1 of 33 GVI Operation Manual This document is the copyright of Astrosys International Ltd and may not be reproduced in total or in part by any means electr...

Page 2: ...6 6 0 PROGRAMMING GV1 17 6 1 Programming 17 6 2 Programming Ports Switches 18 6 3 On board Controls 19 6 3 1 GV1 DIP switches 19 7 0 ELECTRICAL INTERFACE SPECIFICATION 20 7 1 Power 20 7 1 1 Power Supp...

Page 3: ...of the extensive GV1 features A wide range of interfaces including Parallel Pulse Serial MDB ccTalk SSP SGI etc Accepts up to 32 notes per configuration in 4 directions max note width 85mm Accepts no...

Page 4: ...A Power Consumption Idle Standby 450mA 12V typical Validating 1 5A 12V typical Stacking 1 5A 12V typical Peak Inrush Stalled 3 5A 12V Environmental Range Operating Temp 0 to 55 C Operating Hum Up to 9...

Page 5: ...dule can be rotated or removed altogether for rapid access to the notepath surface in conjunction with the hinged Roller Housing assembly of the GV1 The entire ST2 module can be quickly removed from t...

Page 6: ...al Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 6 of 33 The above sequence can also be performed with the ST2 module in place in the GV1 unit Depress Side Latches to release ST2 module lift ou...

Page 7: ...lobal Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 7 of 33 2 2 3 Removing the Cashbox 2 Press Cashbox Release Button 1 Unlock Cas...

Page 8: ...GBA Global Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 8 of 33 3 Remove Cashbox...

Page 9: ...l 2 Runway Gaming 3 Bezel Concealed Metal 4 Bezel Universal 5 Note Entry Adaptor 9 Note Guide 0 None 1 US up to 66mm 3 EU stepped up to 82mm 5 Canada up to 72mm 6 GB stepped up to 85mm 7 India up to 7...

Page 10: ...v2 00 Page 10 of 33 3 0 NOTE ENTRY OPTIONS 3 1 Note Entries GV1 can be fitted with two key styles of Noteguide Entry Universal Note Guide typically for gaming applications Elite Gaming Bezel Entry spe...

Page 11: ...module Outer Inner Noteguide Inserts must be of the same currency type to avoid note handling issues Outer Noteguide Inserts differ between Runway Bezel types and are not interchangeable between the...

Page 12: ...ce looks at taking a GV1 unit and disassembling the Note Entry area for example if the area needed to be reconfigured Reassembly is essentially the reverse process substituting different parts as requ...

Page 13: ...l Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 13 of 33 Slide Clamp moulding 2 back out Unplug PCB loom 3 lift Noteguide Base 4 o...

Page 14: ...cility if specified an Audit PCB is installed inside the Cashbox cap Security Lock for locking the Cashbox to the GV1 unit 12mm Lock fitted as default or Cashbox configured to accept customer supplied...

Page 15: ...ill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 15 of 33 The following illustration shows the Cashbox Lock options GV1 Locking Plate...

Page 16: ...ovided on the steel sideplates for mounting into cages framework Care should be taken that the screw length used is appropriate screws that are excessively long may interfere with functionality such a...

Page 17: ...ce It is worthwhile to understand that the overall functionality of GV1 is split between the ST2 validation module and the GV1 unit itself The ST2 validation module is primarily concerned with the cur...

Page 18: ...s explained in the comprehensive GV1 Reference Manual 6 2 1 Image illustrating Indicator LEDs and programming features 6 2 2 Image illustrating Front Door control area ST2 PUSHBUTTON ST2 DIAGNOSTIC LE...

Page 19: ...with the switch actuator Down flat when viewing the PCB from the front of the GV1 To disable a note locate the appropriate DIP switch and flick to the Up angled position with the GV1 in normal operati...

Page 20: ...ace 7 2 1 General Purpose Open Collector outputs Maximum Open Voltage 40V Maximum Sink Current 50mA Maximum Output Low Voltage 0 4VDC Input low level voltage 0 1V Input high level voltage 3 12V typica...

Page 21: ...on Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 21 of 33 8 0 CONNECTION OPTIONS GBA 20 pin Gaming 20 pin MDB USB Illustration showing the Interface Connector opti...

Page 22: ...dering requirement The listing has the following format Connection Option o Interface GBA 20 pin o Pulse o Parallel o ccTalk o GBA BSCP o Mars Serial A o SSP Gaming 20 pin o Serial Gaming Interface Lo...

Page 23: ...ee pics 1 2 5 The ST2 top half and Rear Housing can both be fully removed if desired see pic 3 6 Pick off and discard any large items of debris from the note path top bottom 7 Using the cotton swab or...

Page 24: ...ead Unit assembly from the GV1 unit if the host enclosure does not allow access to the ST2 validation module and opening Rear Housing 3 Squeeze the release levers for the top half of the ST2 validatio...

Page 25: ...GBA Global Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 25 of 33 3 4...

Page 26: ...GBA Global Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 26 of 33 5...

Page 27: ...e indicators are tri colour capable of glowing Red Green or Orange The indicators enable enhanced diagnostics for the user and for Astrosys personnel when assisting customers from a remote location Th...

Page 28: ...eject Codes Unrecognised Note Red x 1 OASG Reject Red x 2 MASG Reject Orange x 2 Returned note inhibited in config settings Red x 3 Returned note inhibited by host Orange x 3 Transport during note sca...

Page 29: ...sette Green Orange Green Orange OASG Optical Anti Stringing Gate MASG Mechanical Anti Stringing Gate This condition only occurs in serial interfaces e g GBA RS 232 MDB ccTalk Note The GV1 LED Indicato...

Page 30: ...cable s are connected firmly correctly MAKE REFERENCE TO GV1 VAL DIAGNOSTIC LED TABLES 10 1 2 10 1 3 Investigate 1 Power supply and power cable 2 Diagnostics indicator GV1 LED 3 Interface Cable assem...

Page 31: ...GBA Global Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 31 of 33 11 0 DIMENSIONAL DRAWINGS 11 1 Unit without Noteguide...

Page 32: ...GBA Global Bill Acceptors GBA GV1 Operation Manual Astrosys International Ltd October 2018 GBA GV1 Operation Manual v2 00 Page 32 of 33 11 2 Cashbox...

Page 33: ...nalties arising from the adherence to reliance on or interpretation of this document REGIONAL OFFICES AstroSystems Ltd Microsystem Controls Pty Ltd 1 The Quadrangle Unit D2 0 63 85 Turner Street Grove...

Reviews: