background image

3

IV. SWITCHING AMONG DIFFERENT MODES 
Pressing MODE switches the Cost/Price area and kWh/Time area among different modes in a circulation pattern. 

The following Illustrations show the process. Pay attention to the symbols and units on the two areas. 

V. SETTING T1 , T2 AND THE PRICES
Setting the start time and terminal time of Tl
1.   Press 

MODE until the start time or terminal time of Tl is displayed on the screen. 

2.   Press 

PRG to enter setting mode. 

3.   Press 

PRG to select the desired item you want to adjust. The selected item will blink. 

4.   Press 

MODE to adjust the selected item. 

5.  When all adjustments have been completed, select the last item (the rightest item) by pressing 

PRG

6.   Press 

PRG once more to finish the setting. 

Setting price T1/kWh and price T2/kWh 
1.    Press 

MODE until the total energy cost of T1 (for setting price T1 per kWh only) or the total  

energy cost of T2 (for setting price T2 per kWh only) is displayed on the screen. 

2.  Perform steps 2 through 6 of the 

Setting the start time and tenninal time of Tl section. 

Note: 
Price T1 /kWh is the energy price of T1, price T2/kWh is the energy price ofT2. 

Summary of Contents for PM3100

Page 1: ...rd the highest amperage voltage and wattage To operate this instrument you should read the manual first and adjust the settings Then plug the instrument in to a standard AC outlet Finally connect the plug of the appliance to be monitored into the socket of the instrument Features Energy monitor and consumption tracking Maximum amperage voltage and wattage readings Energy cost calculation Energy co...

Page 2: ...hest readings recorded when the corresponding display Is being shown If you switch to another display the highest reading will be cleared READINGS W Watt Wattage Max W Watt Highest recorded wattage used by load V Volt Line Voltage Max V Volt Highest recorded Line Voltage A Ampere Load Current Max A Ampere Highest recorded current drawn by load Overload A Ampere Current Overload Threshold Overload ...

Page 3: ...ess PRG to select the desired item you want to adjust The selected item will blink 4 Press MODE to adjust the selected item 5 When all adjustments have been completed select the last item the rightest item by pressing PRG 6 Press PRG once more to finish the setting Setting price T1 kWh and price T2 kWh 1 Press MODE until the total energy cost of T1 for setting price T1 per kWh only or the total en...

Page 4: ...NS Operating Voltage CAT II 90 125V at 60Hz Maximum Load 1875W 15A Current Range 0 2A 15A Wattage Range 1875W Current Measuring Accuracy 0 10A 2 0 10A 15A 2 5 10D Current Resolution 0 01A Power Resolution 1W kWh Display 0 00kWh 999 99kWh Current Overload Indication EEEE shown on the corresponding display Energy Cost Overflow Indication EEEEE shown on the corresponding display Batteries 1 5V button...

Page 5: ...kee WI 53209 gardnerbender com CARE STORAGE Unit should be kept clean at all times Clean using only a soft cloth or cotton swab with medical alcohol Do not submerge any part of the Power Meter The Power Meter should be stored at room temperature WARRANTY Gardner Bender warrants its product against defects in workmanship and materials for 1 year from date of delivery to user Chain is not warranted ...

Reviews: