background image

2

I I. SCREEN AND BUTTONS

A. "CHANGE" Button

Press this button to scroll through the following readings on the Energy Monitor area: 

B. "MODE" Button

1.  Used to switch among different modes. 

2.  Used for setting adjustment. 

C. "PRG" Button

1.  Used to enter setting mode and select the desired digit or item. 

2.  Used to clear all total cost, energy usage time and total consumed energy data together. 

I I I. ENERGY MONITOR 
Press CHANGE to scroll through the following readings on the energy monitor area:

The voltage reading indicates how many volts are available from your wall socket. The wattage and 

amperage readings indicate the energy presently being used by the appliance. The maximum amperage, 

maximum voltage and maximum wattage readings indicate the highest readings recorded when the 

corresponding display Is being shown. If you switch to another display, the highest reading will be 

cleared.

READINGS
- (W)

 Watt = Wattage

 

-  (Max W)

 Watt = Highest recorded wattage used by load

 

- (V)

 Volt = Line Voltage 

-  (Max V)

 Volt= Highest recorded Line Voltage 

- (A)

 Ampere= Load Current 

-  (Max A)

 Ampere = Highest recorded current drawn by load

 

-  (Overload A)

 Ampere= Current Overload Threshold

 

-  (Overload W)

 Wattage = Wattage Overload Threshold

You can set a desired current or wattage overload threshold. When the present current or  

wattage exceeds the threshold, the symbol "Overload" will blink on display as alarm if a relevant  

display is being shown. 

• Wattage

• Maximum Wattage

• Line Voltage

• Maximum Line Voltage

• Load Current

• Maximum Load Current

• Current Overload Threshold

• Wattage Overload Threshold

• Wattage

• Maximum Wattage

• Line Voltage

• Maximum Line Voltage

• Load Current

• Maximum Load Current

• Current Overload Threshold

• Wattage Overload Threshold

Summary of Contents for PM3100

Page 1: ...rd the highest amperage voltage and wattage To operate this instrument you should read the manual first and adjust the settings Then plug the instrument in to a standard AC outlet Finally connect the plug of the appliance to be monitored into the socket of the instrument Features Energy monitor and consumption tracking Maximum amperage voltage and wattage readings Energy cost calculation Energy co...

Page 2: ...hest readings recorded when the corresponding display Is being shown If you switch to another display the highest reading will be cleared READINGS W Watt Wattage Max W Watt Highest recorded wattage used by load V Volt Line Voltage Max V Volt Highest recorded Line Voltage A Ampere Load Current Max A Ampere Highest recorded current drawn by load Overload A Ampere Current Overload Threshold Overload ...

Page 3: ...ess PRG to select the desired item you want to adjust The selected item will blink 4 Press MODE to adjust the selected item 5 When all adjustments have been completed select the last item the rightest item by pressing PRG 6 Press PRG once more to finish the setting Setting price T1 kWh and price T2 kWh 1 Press MODE until the total energy cost of T1 for setting price T1 per kWh only or the total en...

Page 4: ...NS Operating Voltage CAT II 90 125V at 60Hz Maximum Load 1875W 15A Current Range 0 2A 15A Wattage Range 1875W Current Measuring Accuracy 0 10A 2 0 10A 15A 2 5 10D Current Resolution 0 01A Power Resolution 1W kWh Display 0 00kWh 999 99kWh Current Overload Indication EEEE shown on the corresponding display Energy Cost Overflow Indication EEEEE shown on the corresponding display Batteries 1 5V button...

Page 5: ...kee WI 53209 gardnerbender com CARE STORAGE Unit should be kept clean at all times Clean using only a soft cloth or cotton swab with medical alcohol Do not submerge any part of the Power Meter The Power Meter should be stored at room temperature WARRANTY Gardner Bender warrants its product against defects in workmanship and materials for 1 year from date of delivery to user Chain is not warranted ...

Reviews: