20
TROUBLESHOOTING
UV STATUS LIGHTS
UV Status Lights
UV System Mode
Green
“UV System On”
Light on
Yellow
“UV Lamp Failure”
Light on
Red
“UV Safety Interlock Activated”
Light on
All UV Lamps ON “Normal”
X
One or more UV Lamps not working
X
X
UV Module un-plugged
X
X
No Power to the UV Module (All doors closed)
X
UV Access door Open
X
XG Extractors not in place
X
Exhaust Fan is not running at full speed
X
The UV System is designed to run whenever the Exhaust Fan is running.
The UV Status Lights will only activate when the UV System should be on. (Exhaust Fan running)
“UV System On” (Green) Light
• On when the UV System is energized
“UV Lamp Failure” (Yellow) Light
• On whenever the UV System is energized and one or more of the UV Lamps and/or UV Ballasts have failed or if the UV Lamps
do not have power
• The rest of the UV Lamps will continue to run - call a Certified Service Agent for service
“UV Safety Interlock Activated” (Red) Light
• On when a UV Access Door is Open
• On when an XG Extractor is not in place.
• On when UV Pressure Switch detects that the static pressure is too low.
• All UV Lamps will shut off immediately when any of the above conditions are met.
Normal Operation
• 3 Red lights on
• 6 Green lights on
UV Lamp Failure
• “Summary Alarm” light is off
• The Green light for the UV Lamp / Ballast that has failed will
be off
Note:
• UV Lamps are numbered 1 to 6 from front to back
• UV Ballasts are numbered 1 to 6 from left to right
• The top of the UV Module has several long slots cut out for
ventilation
UV MODULE CONTROLLER STATUS LIGHTS
Summary of Contents for XG-BDL
Page 13: ...10 GFBD EXTERNAL WIRING MULTIPLE SECTION FIGURE 16B GFBD External Wiring Diagram ...
Page 29: ...26 UV HOOD WIRING BOARD SCHEMATIC ...
Page 30: ...27 WIRING DIAGRAM FOR MODEL CUV 100 WITH XG UV SERIES HOODS ...
Page 31: ...28 WIRING DIAGRAM FOR GAD 100 CONTROLLERS WITH GFBD DAMPERS ...
Page 32: ...29 WIRING DIAGRAM FOR GAD 100 CONTROLLERS WITH NO DAMPER ...